Charging a heat pump with refrigerant is best accomplished in the _______ mode.
A: Heating mode
B: Cooling mode
C: Defrost mode
D: Emergency heating mode - CORRECT ANSWER-B: Cooling mode
Heat pumps can provide both heating in the winter...
NATE Heat Pump Exam Questions and Answers 100% Correct Charging a heat pump with refrigerant is best accomplished in the _______ mode. A: Heating mode B: Cooling mode C: Defrost mode D: Emergency heating mode - CORRECT ANSWER -B: Cooling mode Heat pumps can provide both heating in the winter and cooling in the summer. In which mode is the heat pump more efficient? A: Heating mode B: Cooling mode C: Defrost mode D: Emergency heating mode - CORRECT ANSWER -A: Heating mode Which of the following components is exclusive to the heat pump? A: Condenser B: Oil separator C: Reversing valve D: Accumulator - CORRECT ANSWER -C: Reversing valve Which of the following airflow rates is the most reasonable for a heat pump system operating in the heating cycle? A: 200 cfm per ton B: 300 cfm per ton C: 400 cfm per ton D: 450 cfm per ton - CORRECT ANSWER -D: 450 cfm per ton During the heat pump's cooling cycle, the outdoor coil is utilized as a _________ while the indoor coil is utilized as a____________. A: Condenser, evaporator B: Evaporator, condenser C: Compressor, accumulator D: Accumulator, condenser - CORRECT ANSWER -A: Condenser, evaporator Heat is present in winter outdoor air until the outside air ambient temperature reaches a low temperature of: A: 0 degrees F B: 32 degrees F C: 273 degrees F D: -459 degrees F - CORRECT ANSWER -D: -459 degrees F Technically this is true, but not practical. A heat pump is doing good to continue to work below 10 deg F unless specifically designed for lower temperatures. The heat pump utilizes: A: Two filter -driers with check valves B: One bi -flow filter -drier C: A single mono -flow filter -drier in the liquid line D: Some use the bi -flow filter -drier and others use two filter -driers with check valves - CORRECT ANSWER -D: Some use the bi -flow- filter-drier and others use two filter -
driers with check valves The correct way to size a heat pump is to perform both heating and cooling load calculations and select the heat pump size by: A: Adding the heating load and cooling loads B: Subtracting the smaller load from the larger load
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller StudyCenter1. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $13.99. You're not tied to anything after your purchase.