JATC Homework Code Test | 100% Correct Answers | Verified | Latest 2024 Version
JATC Homework Code Test | 100% Correct Answers | Verified | Latest 2024 Version How many wires do you need to transmit 3 phase power - 3 wires The code defines a "continuous" load as one in which the load is likely to continue for _ hour or more. - 3 A transformer can be fed off the secondary feed. (T/F) - True According to code, a wire located in a partially protected area such as under a roofed open porch would be located in? - A damp location Article 100 informational note In dealing with motors and related equipment when the code specifies "in sight from" it means that....... - The equipment must be visible. Must not be more than 50ft. Article 100 What is not permitted for connecting #6 wire and larger to terminal parts? - Wire binding screws 110.14(A) What is the head space required for a panel? - 6.5 ft 110.26(A)(3) In all cases, the work space shall permit at least a _ degree opening of equipment doors. - 90° 110.26(A)(2) The terminal for the _ shall be the one connected to the screw shell. - Grounded conductor 200.10(C) Circuits fed from direct current systems ungrounded conductors 4awg or larger shall _ at all terminations. - Identify by polarity 210.5(C)(2) In a dwelling unit kitchen which receptacles need to be GFCI A) A receptacle installed to serve kitchen countertop surface B) Receptacle installed under sink C) A receptacle installed within 6ft from the the top inside edge of the bowl of the sink. D) A and C E) All of the above - D 210.8(A)(6&7) A recptacle is 6.5ft away from the outside edge of the bathtub or shower stall needs to be GFCI protected. (T/F) - False Anything installed within 6' needs GFCI, unless specified it is in a bathroom 210.8(A)(9) Laundry branch circuits shall be on a _ branch circuit. - 20A 210.11(C)(2) In general, branch circuit conductors supplying a single motor should have a capacity not less than _% of the motor full loaded circuit rating. - 125% 210.19(A) 430.22 How many 2a fluorescent lights running for 10 hours straight can you put on a 20a branch circuit? - 8 20x.8=16 16/2=8 210.19(A)(1)(a) The branch circuit is rated at 15a, what is the total rating of the equipment fasted in place where lighting units are also supplied? A) 15a B) 7.5a
Written for
- Institution
- JATC Homework Code
- Course
- JATC Homework Code
Document information
- Uploaded on
- May 29, 2024
- Number of pages
- 13
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
jatc homework code test 100 correct answers v
Also available in package deal