Med Gas 84 Questions Latest Update with Verified Answers
Med Gas 84 Questions Latest Update with Verified Answers A ______ system is an assembly of equipment such as storage containers, pressure regulators, pressure relief devices, vaporizers, manifolds, and interconnecting piping that has a storage capacity of more than 20,000 cubic feet (at normal temperature and pressure), including unconnected reserves on hand at the site. a. Bulk oxygen b. High pressure maniifold c. Micro bulk d. Vacuum a A bulk cryogenic supply contains parallel-piped duplex line regulators. Which of the following is a requirement for the regulators? a. A balanced design b. Check valves on the source side of each regulator c. Contains NO polymeric materials. d. Each regulator sized for 110 percent of the peak calculated demand a A document in which the main text contains only mandatory provisions. Non-mandatory provisions are located in the appendix or the annex. This is the NFPA 99 definition for which of the following? a. Code b. Guide c. Reference d. Standard d A facility is in the planning stages of installing an emergency oxygen service connection (EOSC). How many feet is the minimum amount of clearance required around this connection? a. 1 foot b. 3 feet c. 5 feet d. Clearance must be 1-1/2 times the width of the auxiliary source for servicing the system b A medical gas master or area alarm panel should be set to actuate a(an) _______ indicator when the communication with an alarm initiating device is disconnected. a. Audible b. Audible and visual c. High and low d. Visual b A new bulk system is to be installed at a local hospital. New, in compliance with NFPA 70, wiring will be installed underground from the initiating device to a junction box located where the wiring first enters the building. NFPA 99 permits what minimum number of sets of wires to connect the initiating device with the junction box for each signal? a. 1 b. 2 c. 3 d. 4 a A patient care room is any room of a health care facility wherein patients are intended to be _____. a. Either admitted or discharged b. Examined or treated c. Interviewed d. Sent for x-rays b A standard gauge pressure of 160-185 psi applies to which of the following? a. Instrument air b. Laboratory air c. Laboratory vacuum d. Non-medical air a A valve installed in each medical gas and vacuum piping system shall be tested to verify which of the following? a. Date of installation b. Flow and pressure drops c. Pressure range d. Proper operation and rooms or areas
Written for
- Institution
- Med Gas 84
- Course
- Med Gas 84
Document information
- Uploaded on
- June 13, 2024
- Number of pages
- 32
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
med gas 84 questions latest update with verified
Also available in package deal