The bucky slot opening in the side of the table must be automatically covered with _____ mm
Pb during fluoroscopy. - Answer 0.25
The leakage radiation limit for x-ray tubes is less than____mGy/hr at 1 meter from the tube
housing - Answer 1
A secondary barrier is designed to absorb____ radiation...
LRA 216 Final Quiz with 100% Correct Sol utions The bucky slot opening in the side of the table must be automatically covered with _____ mm Pb during fluoroscopy. - Answer 0.25 The leakage radiation limit for x -ray tubes is less than____mGy/hr at 1 meter from the tube housing - Answer 1 A secondary barrier is designed to absorb____ radiation - Answer leakage Scatter The___is used for precise calibration of the output inte nsity of diagnostic x -ray tubes - Answer ion chamber The source -to-skin distance must be no less than___cm on stationary fluoroscopes - Answer 38cm The output intensities of reproduced exposures should not vary more than _____% from each other. - Answer 5% A quantity that reflects both dose and volume of tissue irradiated is the _____ - Answer dose area product Gas-filled radiation detectors are based on the____ - Answer ionization of gas There are no circumstances under which a technologist should be given an involuntary leave of absence due to pregnancy. - Answer True Personnel working in interventional radiography should be provided with _____. - Answer extremity monitoring The tissue weighing factor has a higher value for tissues with more - Answer radiosensitivity Occupational dose is described as - Answer dose equ ivalent A protective apron with a thickness of 0.25 mm lead equivalent is the minimum required - Answer True Technologists working fluoroscopy should use the radiologist as shielding whenever possible in addition to the apron and curtain. - Answer True For nursing personnel present during mobile x -ray imaging, a personnel monitoring device is required _____. - Answer not at all The lowest occupational exposure of diagnostic x -ray personnel occurs during___ - Answer Ct Mammography The lens of the eye sh ould never receive more than____per year - Answer 150mSv (15 rem) Optically stimulated luminescence (OSL) montiors are superior to the thermoluminescence dosimeters in that they are___ - Answer more sensitive to low exposure Every radiology department sh ould provide a radiation safety program that includes: - Answer Training new employees Periodic in -service for all employees Counseling during pregancy The preferred way to hold patients who are unable to support themselves is to use___ - Answer Restrain ing device
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Examsplug. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $10.49. You're not tied to anything after your purchase.