1/4" - correct answer Threads of drainage fittings shall be tapped as to allow _____
pitch per foot
4 lbs - correct answer Lead used for safe pans shall not be less than ________ per
square foot
Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - correct answer Name 3
allowable materials for the DWV system "underground"
1-1/4" - 1 dfu's
1-1/2" - 3 dfu's
2" - 4 dfu's
3" 6 dfu's
4" - dfu's - correct answer What are the fixture unit values for the following traps
Double fixture fitting - correct answer What type of fitting is used for continuous waste
and venting of lavatories back to back?
1" - correct answer Caulk joints for cast iron bell and spigot shall be filled with molten
lead to a depth of not less than ________?
Wye, Combination Wye w/ 1/8 bend, Long sweep - correct answer What type of fitting
or fittings can be used to connect horizontal drainage to another horizontal drainage
line?
- Each horizontal drainage pipe shall be provided with a cleat at its upper terminal
- Horizontal run more than 100'
- Each horizontal change of direction exceeding 135°
- Front Main Cleanout - correct answer Cleanout locations required by code
100' - correct answer Maximum distance a cleanup can be spaced apart
12"
18" - correct answer Minimum clearance in front of a cleanup for 2" or less
Minimum clearance in front of a cleanup for 2" or more
20' - correct answer Underfloor cleanup shall not be located more than _____ from an
access door, trap door, or crawl hole
Back Water Valve - correct answer When plumbing fixtures are installed on a floor level
lower than the next upstream manhole cover of the sewer, such drainage piping shall be
protected from backflow of sewage by a ____________
,20 - correct answer Sewage ejectors receiving the discharge of water closets or ruinals
shall have a discharge capacity not less than ___ gallons per minute
2" - correct answer What is the minimum size discharge pipe for an ejector installed in a
single dwelling?
2" - correct answer The lowest inlet connected to the ejector pump shall have a
clearance of not less than ____ from the high water or starting level of the sump.
Yes, with prior approval of the AHJ - correct answer Can macerating toilet systems be
installed instead of a sewage pump system
3/4" - correct answer What is the minimum size discharge pipe for a macerating toilet
system
1/4" per foot - correct answer What is the minimum pitch required fora 2" horizontal
drain?
Swing check valve - correct answer The discharge line from an ejector pump shall be
provided with an accessible ___________ and gate or ball valve.
Downstream of the backwater valve - correct answer Where shall the gate valve be
located on the discharge line on an ejector pump
8' - correct answer Drainage connections shall not be made into a drainage piping
system within ________ of an vertical or horizontal change in direction of a stack
containing suds producing fixtures.
10' Head of water for 15 minutes
5 psi for and air test - correct answer What are the requirements when testing the DWV
system Water and Air?
When the dwelling is more than 200' away from the sewer. - correct answer When is the
public sewer considered not being available?
2' away from the building - correct answer At what point does the building sewer begin?
DFU's - correct answer How is the size of the building sewer determined?
300' - correct answer What is the maximum distance allowed between approved
manholes?
12" - correct answer When a water pipe and sewer pipe are placed in a common trench
what is the minimum distance above the top of the sewer line to the bottom of the water
pipe?
, 12" - correct answer When a water pipe and sewer pipe are placed in a common trench
what is the minimum clear horizontal distance the water pipe shall be from the sewer
pipe?
By taking 80% of the total DFU's = 173 DFU's - correct answer A 4' drainage line has to
be run at a pitch of 1/8" per foot. How is the maximum fixture unit low now determined?
Provide minimum requirements and standards for the protection of the public health,
safety, and welfare. - correct answer Purpose of plumbing code.
Capped - correct answer Openings into drainage or vent system excepting those
opening to which plumbing fixtures are properly connected or which constitute vent
terminals shall be permanently plugged or _________ in an approved manner.
Owner or owners agent - correct answer Who is responsible for maintaining the
plumbing and drainage system in a building?
Work or systems that have already been installed prior to the effective date of the
existing code. - correct answer What is meant by the term "existing work"?
Blockages or leaks - correct answer What type of work is exempt from a plumbing
permit?
180 Days - correct answer If work is not started, how many days is a permit valid?
After it has been tested, inspected, and approved - correct answer When can plumbing
work be covered and concealed?
Person with the permit, doing the work - correct answer Who notifies the authority have
jurisdiction when plumbing work is ready for inspections?
Prevent siphonage - correct answer What is the purpose of a vacuum relief valve
To slow corrosion of the inside of the tank - correct answer What is the purpose of the
anode rod?
To send cold water to the bottom of the tank - correct answer What is the purpose of the
dip tube?
To prevent siphonage and back pressure on the dip tube. - correct answer What is the
purpose of the anti-siphon hole?
When the water temperature drops below a set temperature the immersion element
turns on to reheat the water. - correct answer Explain how the electric immersion
elements work on an electric water heater.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller puritywanjihia. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $13.99. You're not tied to anything after your purchase.