SOLVED
Which of the following best describes Voltage? - answerThe force of electricity caused by a difference in charge
In which type of circuit are components connected along a single path? - answerSeries circuit
What is the minimum amount of current sufficient to stop your heart? - answer100 mA
What is the term for the permanent joining of electrical parts? - answerBonding
What is an electrode? - answerGrounding hardware
What does proper grounding protect? Select all answers that apply. - answer-
Equipment
-Property
-The Public
-Network
True or False? 4tel or VoiceTest can be used to determine capacitance balance. - answerTrue
What is the standard ground? - answerThe electrical utility's MGM
What is a Tii 356? - answerA protector
What are the colours pair number 18? - answerYellow/Green
What are the color pair number 22? - answerViolet/Orange
What are the color pair number 9? - answerRed/Brown
What is the pair number (between 1 and 25) for white/green? - answer3
What is the pair number (between 1 and 25) for red/orange? - answer7
Which of the following is a bonding and grounding rule? Select all answers that apply. - answerAll ground and bond wires should be kept as short as possible The appropriate size of ground wire should be used based on the number of protectors
All connections should be made with standard clamps and should be tight
All new ground wire should have green insulation
The Canadian Radio-Television and Telecommunications Commission (CRTC) describes the point of demarcation as: - answerThe physical location where the wires and facilities on each side of the point are under the responsibility and control of different parties
What is the binder colour for pair 145? - answerBlue/Red
How would a tip to ground short read on ASAP/Fortel? - answerLow resistance on the Tip
How many customer drop cables can the aerial Fujikura terminals accommodate? - answer12 or 24
True or False? Only AFL Fujikura connector ends can be used to terminate AFL Fujikura fibre. - answerFalse
What type of fibre connector ends does TELUS use in drop placement? - answerGreen APC ends
Can you use Corning connector ends on an AFL Fujikura drop? - answerYes
Can you add additional flat drop cables after the initial installation? - answerYes
Which ports should be active on an Optical Network Termination? - answerLine 1 and/or
2
LAN 1
True or False? One ONT can service multiple customers in Multi Dwelling Units. - answerFalse
True or False? The Uninterruptible Power Supply must be installed in a location where ambient temperature ranges from 0°C (32°F) to 40°C (104°F). - answerTrue
True or False? The lights on the G240-A ONT indicating proper connection on the GPON network are PWR, NTRK and MGNT. - answerTrue True or False? You should take all garbage with you when leaving a customer's premises. - answerTrue
What is the maximum loss we should see when testing with the Passive Optical Network epm-50 power meter. - answer-25 dBm
What does the acronym IDEAA stand for? - answerIntegrated Distribution Enabling Access Apparatus
Which features are unique to the IDEAA cabinet versus existing FDH's in use with TELUS? - answerIDEAA Modules
Swing down tray with distributions fibres
How many millimeters should you leave at the end of a fibre in preparation to attach an AFL Fujikura FASTConnect connector? - answer10.5mm for 250 and 9000 micrometer cables
True or False? In order for an alarm jack to meet TELUS standards it must be placed after the POTS splitter in the installation wiring. - answerTrue
If encountered on site, legacy CCB blocks that are damaged must be replaced with which of the following? - answerTii 68T
What type of fire rated Cat5e cable is to be used inside buildings? - answerCMR
Which of the following statements is true about UV rated CMX Cat5e cable? - answerIt can only be used outdoors since the CMX jacket emits toxic fumes when subjected to high heat
Fill in the blank: To install to the _______ jack, you must first fan the wires and then attach them using the 110 termination tool, according to the T568A standard. - answerLeviton
Which of the following devices can be used as a demarcation point? Select all that apply. - answer- Test jack
- Tii 356
- Leviton jack
Which of the following could represent a potential hazard when drilling and fishing wire?
Select all that apply - answerNeglecting to wear safety glasses
Drilling close to electrical wiring
What is the purpose of a fishing or drill bit with a hole in the end? - answerThe hole is for pulling the bale through after drilling the hole and removing the bit