Exam (elaborations)
Journeyman Electrician Practice Test With Complete Questions And Answers Rated A
Course
Electrical Journeyman
Institution
Electrical Journeyman
Journeyman Electrician Practice Test With Complete Questions And Answers Rated A
[Show more]
Preview 2 out of 10 pages
Uploaded on
August 3, 2024
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Institution
Electrical Journeyman
Course
Electrical Journeyman
$12.49
Also available in package deal from $24.99
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal (1)
1. Exam (elaborations) - Lectrical journeyman test 2020 with complete questions and answers rated a.
2. Exam (elaborations) - Journeyman electrician exam questions and answers.
3. Exam (elaborations) - Journeyman electrician exam prep with complete questions and answers rated a
4. Exam (elaborations) - Journeyman electrician practice test with complete questions and answers rated a
5. Exam (elaborations) - Journeyman electrician practice exam -7 with complete questions and answers rated a+
6. Exam (elaborations) - Psi journeyman online practice test with complete questions and answers rated a.
7. Exam (elaborations) - Journeyman electrician (2020nec) with complete questions and answers rated a+.
Show more
Journeyman Electrician Practice Test
With Complete Questions And Answers
Rated A+
Conductors .with ._____ .marked .on .the .insulation .are .NOT .approved .for .use .in .a .wet .l
ocation. .- .Correct . .Answer .- .THHN
conductors .with .THHN .insulation .are .approved .for .use .in .dry .and .damp .locations .onl
y .and .conductors .with .THWN, .THHW, .and .THW .insulation .are .recognized .for .use .in .
dry .and .wet .locations.
Given: .A .one-
family .dwelling .unit .with .a .demand .load .of .200 .amperes .is .supplied .with .a .120/240 .v
olt, .single-
phase, .electrical .system .from .the .local .utility .company. .What .is .the .MINIMUM .size .al
uminum .THW .conductors .required .for .use .as .service-
entrance .conductors .for .this .residence? .- .Correct . .Answer .- .4/0 .AWG
one-family .dwelling .120/240 .volt, .single-phase, .service-
entrance .conductors .to .be .sized .at .an .ampacity .of .not .less .than .83% .of .the .service .r
ating. .Therefore, .200 .amperes .x .83% .= .166 .amperes; .size .4/0 .AWG .THW .aluminum .
conductors .with .an .allowable .ampacity .of .180 .amperes .should .be .selected .for .this .dw
elling.
Where .a .150 .kVA, .single-
phase .transformer .having .a .secondary .voltage .of .120/240 .is .installed .at .a .multi-family
.dwelling, .the .full-load .current .rating, .in .amperes, .of .the .secondary .is ._____. .- .Correct
. .Answer .- .625 .amperes
To .find .the .full-load .current .rating .of .the .single-phase .transformer .apply .the .single-
phase .current .formula .as .shown:I .= .(150 .kVA .x .1000) ./ .240 .volts .= .15,000/240 .= .625
.amperes
Which .one .of .the .following .listed .circuit .breakers .is .NOT .a .standard .ampere .rating? .-
.Correct . .Answer .- .75 .amperes
, the .standard .ampere .ratings .for .fuses .and .circuit .breakers. .A .circuit .breaker .with .an .
ampere .rating .of .75 .amperes .is .not .a .standard .ampere .rating.
The .MINIMUM .length .of .free .conductor .to .be .left .at .each .junction .box .for .the .purpose
.of .splicing .conductors, .or .making .connections .to .illuminares .or .devices .shall .be .____
_ .. .- .Correct . .Answer .- .6 .inches
free .conductor .is .to .be .left .at .each .junction .box .for .splices .or .the .connection .of .lumin
aires .or .devices. .The .intent .of .this .rule .is .to .ensure .enough .conductor .slack .for .the .te
rminal .connections .or .splices .to .be .made .easily.
In .general, .overhead .service-
drop .conductors .shall .NOT .be .smaller .than ._____. .- .Correct . .Answer .- .8 .AWG .coppe
r
overhead .service-
drop .conductors .to .be .not .smaller .than .8 .AWG .copper .or .6 .AWG .aluminum .or .coppe
r-clad .aluminum. .Do .not .get .service-
drop .conductors, .the .overhead .conductors .between .the .utility .electric .supply .system .a
nd .the .service .point, .confused .with .the .service-
entrance .conductors, .the .conductors .from .the .service .point .from .the .utility .company .t
o .the .service .disconnecting .means.
When .a .galvanized .eye-
bolt .is .to .be .used .as .the .point .of .attachment .for .an .electrical .service, .the .NEC .requir
es .the .eye-
bolt .to .be .installed .NOT .less .than ._____ .above .finished .grade. .- .Correct . .Answer .- .1
0 .ft.
provide .adequate .vertical .clearance .of .the .conductors .and .prevent .physical .damage .t
o .the .conductors .and .prevent .persons .from .making .accidental .contact .with .the .condu
ctors .which .may .create .a .shock .hazard .or .electrocution. .In .no .case .shall .the .point .of .
attachment .of .the .service-
drop .conductors .to .be .less .than .10 .ft. .above .finished .grade.
Why .is .electrical .continuity .required .for .metallic .conduit? .- .Correct . .Answer .- .To .estab
lish .an .effective .ground-fault .path .and .facilitate .the .operation .of .the .over-
current .protective .device.
Electrical .continuity .is .required .for .metallic .conduit .to .establish .an .effective .ground-
fault .path .and .facilitate .the .operation .of .the .overcurrent .protective .device.
In .dwelling .units, .receptacle .outlets .installed .for .countertop .surfaces, .must .be .located .
above, .but .NOT .more .than ._____ .above .the .countertop .or .work .surface. .- .Correct . .A
nswer .- .20 .inches