100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Building Analysis Professional Exam Review/ ANSI/BPI Standard Exam | Questions & Answers (100 %Score) Latest Updated 2024/2025 Comprehensive Questions A+ Graded Answers | With Expert Solutions $13.48   Add to cart

Exam (elaborations)

Building Analysis Professional Exam Review/ ANSI/BPI Standard Exam | Questions & Answers (100 %Score) Latest Updated 2024/2025 Comprehensive Questions A+ Graded Answers | With Expert Solutions

 4 views  0 purchase
  • Course
  • BPI
  • Institution
  • BPI

Building Analysis Professional Exam Review/ ANSI/BPI Standard Exam | Questions & Answers (100 %Score) Latest Updated 2024/2025 Comprehensive Questions A+ Graded Answers | With Expert Solutions

Preview 2 out of 7  pages

  • August 4, 2024
  • 7
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • BPI
  • BPI
avatar-seller
VasilyKichigin
Building Analysis Professional Exam Review/ ANSI/BPI Standard Exam | Questions &
Answers (100 %Score) Latest Updated 2024/2025 Comprehensive Questions A+ Graded
Answers | With Expert Solutions


According to Ansi/BPI 1200 standard, which of the following unvented heating would need to be
removed from service? - the 15,000 btu/hr. from the bedroom (review the standard)



A natural draft furnace is back drafting regardless of the caz door position. and air handler operation. -
(According to ansi/bpi1200 standard. have a qualified professional evalute it. BPI standed p.41)



Review picture of air conditioner, what is the nominal rating for this unit? And if the work order called 3
ton and was the installed is this an issues - Rember 12,00 btu = 1 ton, 2 ton system , look at model
number, incremented of 12 "24" in model number 24,000btu/hr. or 2 tons of coolings. yes, it would be
undersized.



a customer recieves thier utility bills for the year. what is the annual heating load in terms for the
heationg season from oct1st - mau 31st? - look at graph and calculate the months



savings to investment picture - look at picture graph an identify which window is label incorrect (window
replacement SIR 4.5)



Energy Model software - A computer model created to test or verify the thermal/energy performance of
the building, particularly the facade and mechanical systems ....Calculates return on investments



what would happen if the orientation was inputted wrong into the energy modeling software. - the
orientation of the software would affect the ROI



if the walls were input 20% less than actual wall? - the calculation on ROI for cellulose wall insulation
would be affected.



what set points would not be monitored for energy consumption. - Humidity control settings.



how to calibrate the energy model software? - input 1 year of energy bills.

, Air conditioning installation should match the projected load of the home or dwelling. - do not install
what you have taken out.



RMS - is a book used to eistamate labor and materials



spay foam (polyurethane) - an ignition barrier is a material used with foam insulation to prevent the
foam from igniting.



Ventilation - calculate using formula.



ventilation purpose - is to dilute indoor air pollutants



the occupied floor area is used for calculating? - the ventilation requirements



if the buildings air flow is below the minimum air ventilation requirements - mechanical ventilation must
be supplied.



if knob-and-tube wiring is present in the attic? - list in the work order as a potential hazard



decommission knob and tube when? - prior to installing insulation



depending on the situation, the elctrican may choose one of these two options for knob and tube, -
decommission and replace with non-metallic (nm) sheathed electrical cable.



Combustion Air Picture, do these combustion appliances need additinal combustion air? - yes, the
appliance required a volume of 4000 cubic feet.



how to calculate combustion air. - Step 1. calculate room volume (l 10x w12 x h8=960)

Step 2. total appliance ratings btu's / by 1000. (8000/1000=80) Step 3. room volume960/ 80 = 12 cuft
*** look at step 3 and if the number is less than 50 cuft air is needed!!!

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller VasilyKichigin. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.48. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62890 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.48
  • (0)
  Add to cart