What type of construction uses heavy timbers AND HIGHLIGHT CONSTRUCTION TYPES - correct answer
✔✔type IV construction uses heavy timbers - the exterior is made of non-combustible materials and the
interior of solid or laminated wood.
Headroom required in a multistory parking garage - correct answer ✔✔7 foot
IF you are operating a forklift in a warehouse building with steel columns. What is the minimum height
to fireproof the columns to protect them from impact? - correct answer ✔✔5 feet
What must be the temperature when using Sprayed Fire resistant material (SRFM). - correct answer
✔✔The temperature must be at least 40 degrees for 24 hours
How high must parapet walls be - correct answer ✔✔Parapet walls must be at least 30" above where the
roof intersects the wall
What is the thickness of smoke barriers in steel group I-3 buildings - correct answer ✔✔minimum 0.10
inch thickness
,Shafts in building with more than ________ must have how many hours of fire rating. - correct answer
✔✔4 stories : 2 hours
137 - Table 716.6 - Fire window assembly fire protection ratings - correct answer ✔✔Table 716.6 - Fire
window assembly fire protection ratings
What is the fire rating on an 2 layers of 5/8" of gypsum board (drywall) - correct answer ✔✔2 hours
What material do you use to fire protect steel columns - correct answer ✔✔gypsum wallboard.
What is finished wood flooring permitted to be attached to - correct answer ✔✔embedded or fire
blocked wood sleepers
Can you occupy a structure or portion of a structure that has not been fire protection systems - correct
answer ✔✔No, it is unlawful
Where should alarm signals be automatically be transmitted to - correct answer ✔✔approved
supervising station
Where smoke alarms required, where should they get their power source from - correct answer
✔✔primary power from the building wiring, should not have on off switch and have a battery backup.
What is the maximum and minimum height for fire alarm boxes - correct answer ✔✔top of box at 42"
minimum and 48" maximum height from the floor.
What are the methods to supervise open backflow prevention valves - correct answer ✔✔1. Central
station/remote station signaling.
2. Local signaling that will cause the sounding of an audible signal at a attendants location.
3. Locking valves open
4.sealing of valves and approved weekly recorded inspection.
,What is the minimum egress height of a ceiling - correct answer ✔✔7 feet 6 inches.
Maximum Floor area allowance per occupant - correct answer ✔✔100SF per occupant
When Doors are fully opened shall not reduce the width by more than - correct answer ✔✔7 inches
What is the length of time that an Emergency Power system illuminate for - correct answer ✔✔90
minutes.
When must a building have an elevator - correct answer ✔✔When its more than 3 stories high
What is the size of a refuge area for a wheel chair - correct answer ✔✔30" x 48".
All separation areas of refuge have to be separated by - correct answer ✔✔a smoke barrier.
What is the minimum width of a door opening - correct answer ✔✔32"
The minimum height of interior door is - correct answer ✔✔80"
Which way must the doors swing open when serving a room or area containing more than 50 occupants
- correct answer ✔✔the doors must swing open in the direction of egress
How much pressure for nonfire interior door to open - correct answer ✔✔5 lbs
What type of hardware is required on doors with occupant loads of more than 50. - correct answer
✔✔PANIC hardware
Minimum headroom height for stairway - correct answer ✔✔6"8'
, Maximum Riser height for stairway - correct answer ✔✔7"
What is the maximum height from the floor for Emergency Escape and rescue opening sills - correct
answer ✔✔44" above the floor
Required number of Accessible parking spaces required for a 60 space lot - correct answer ✔✔3
accessible spaces
Van Parking Spaces - correct answer ✔✔Must all be on one level
What percentage of the total air flow must be from the eaves - correct answer ✔✔50- 60%
What is the spacing of fastenings(studs) for exterior metal siding - correct answer ✔✔should be spaced
24" vertically or horizontally
Asphalt shingles Roof Slopes 2:12 - correct answer ✔✔need two plys of 15 pound felt
Asphalt shingles Roof Slopes 4:12 - correct answer ✔✔need one ply of 15 pound felt
Asphalt shingles Roof - correct answer ✔✔Type A and most fire resistant
319 - TABLE 1507.2.9.2 Valley Lining Material Thickness - correct answer ✔✔319 - TABLE 1507.2.9.2
Valley Lining Material Thickness
326 - TABLES 1507.8.7 and 9.8 Wood Shingle and Shake Exposure Tables two tables one for shakes and
one for shingles - correct answer ✔✔326 - TABLES 1507.8.7 and 9.8 Wood Shingle and Shake Exposure
Tables
What is the minimum slope for metal shingles - correct answer ✔✔3:12
What is the minimum slope for built up roofs - correct answer ✔✔¼: 12 (2%) slope for drainage.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller BukayoSaka120. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $19.99. You're not tied to anything after your purchase.