100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ABYC, Electrical Exam - Study Guide Questions with Solutions $13.49   Add to cart

Exam (elaborations)

ABYC, Electrical Exam - Study Guide Questions with Solutions

 9 views  0 purchase
  • Course
  • Abyc
  • Institution
  • Abyc

ABYC, Electrical Exam - Study Guide Questions with Solutions The minimum amp circuit breaker that should be used to protect a 120V water heater circuit with a 1600 watt element would be rated at ________ amps. 15 amps When testing for excessive EMF emission near a conductor or appliance, ...

[Show more]

Preview 2 out of 5  pages

  • August 5, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Abyc
  • Abyc
avatar-seller
Dreamer252
ABYC, Electrical Exam - Study Guide
Questions with Solutions

The minimum amp circuit breaker that should be used to protect a 120V water heater
circuit with a 1600 watt element would be rated at ________ amps. - answer15 amps

When testing for excessive EMF emission near a conductor or appliance, the tool of
choice is a(n) ____________ - answer Gauss Meter

Thr primary problem with using a series circuit to supply multiple loads is that? - answer
Voltage drop through the circuit will be excessive

The most common electrical circuit problem in marine applications is a(n)
____________ - answer unwanted open

The primary by-product of excessive electrical resistance is ___________ - answer heat

One horsepower is equal to ________ watts - answer746

Excessive electrical resistance can be caused by? - answer undersized wire, loose
connections, and corrosion

The tool of choice for tracing shorted and open circuits is the ________. – answer TDR
(Time Domain Reflectometer)

What material is recommended for clamping conductors over egines and moving
machinery? - answerMetal (w/ insulated inserts)

What is the acceptable minimum clearance for routing wire near a DRY exhaust
section? - answer9in (225mm)

The maximum number of terminals allowed to be attached to any one terminal stud is
______. - answer4

How much current should flow through the DC grounding conductor in a 25 amp DC
motor circuit? - answer0 amps (grounding conductor)

Where the ampacity of each individual conductor is sufficient to carry the entire load
current shared by the parallel conductors, the allowable size (and larger) is ____awg for
connecting parallel conductors. - answer8

, Running a cable to a DC panelboard (3% VD), 15' from the batteries (30' circuit), 12V
system with a max current of 90 amps. What is the cable gauge for this run? - answer0
AWG

DC grounded conductors on new boats that are also equipped with AC systems should
use __________ colored insulation. - answeryellow

The maximum spacing for cable run support is _____ - answer18 in (450mm)

The smallest wire gauge cable allowed for unsheathed wire runs through the boat is
___. - answer16 AWG

What degree F above ambient temperature indicates a "hot spot" in general. -
answer25F

Up to how many volts is considered acceptable with a neutral to ground leakage test? -
answer2V

What % voltage swing is considered normal with AC nominal voltage? - answer+/- 10%

How much simulated theoretical voltage drop is considered too much with a 15A load? -
answer15.5%

According to the ABYC, the shore-power grounded conductor should: - answerB. Not be
grounded onboard the boat

If a customer complains about receiving shocks from his/her boat when the boat is
plugged into shore power, the first test should be a: - answerA. polarity check of the
shore cord

If a customer complains of low voltage at the AC panel, the technician should first: -
answerB. check voltage at the dock pedestal

A costomer complains about a reverse polarity problem. All of the following are likely
causes except: - answerC. an open neutral

In a galvanic isolator installation, which of the following could cause a loss of galvanic
isolation? - answerD. all of the above

Tech A says that a generators neutral and ground must be tied together when the
generator is supplying AC power. Tech B says they must always be kept isolated.
Which tech is correct? - answerA. tech A

A dropped neutral conductor in a 240/120V shore power system will most likely show up
as: - answerD. burned out 120V appliances

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Dreamer252. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80461 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.49
  • (0)
  Add to cart