100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
EPA 608 UNIVERSAL EXAM ACTUAL EXAM ALL 250 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+ What are two factors that, if present, are most likely to lead to an explosion with hydrocarbon refriger $17.99   Add to cart

Exam (elaborations)

EPA 608 UNIVERSAL EXAM ACTUAL EXAM ALL 250 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+ What are two factors that, if present, are most likely to lead to an explosion with hydrocarbon refriger

 8 views  0 purchase
  • Course
  • EPA 608 UNIVERSAL
  • Institution
  • EPA 608 UNIVERSAL

EPA 608 UNIVERSAL EXAM ACTUAL EXAM ALL 250 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+ What are two factors that, if present, are most likely to lead to an explosion with hydrocarbon refrigerants? EPA 608 UNIVERSAL EXAM ACTUAL EXAM ALL...

[Show more]

Preview 3 out of 24  pages

  • August 9, 2024
  • 24
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • EPA 608 UNIVERSAL
  • EPA 608 UNIVERSAL
avatar-seller
examiner356
EPA 608 UNIVERSAL EXAM 2023-2024 ACTUAL EXAM
ALL 250 QUESTIONS AND CORRECT DETAILED
ANSWERS WITH RATIONALES (VERIFIED ANSWERS)
|ALREADY GRADED A+
What are two factors that, if present, are most likely to lead to an explosion with hydrocarbon
refrigerants? - ANSWER-A sufficient concentration of the refrigeration in the space and an ignition
source



An appliance normally containing more than 50 pounds of R-22 refrigerant was found to have a 35%
annual leak rate. After the repair, how many successful verification tests are required? - ANSWER-Two.
Performed before the appliance is recharged



All appliances must be equipped with a service aperture or process stub which is used when adding or
removing refrigerant from the appliance. What is typically used on small appliances? - ANSWER-A
straight piece of tubing that is entered using a piercing access valve. Process Tube



What is the primary purpose of a purge unit on a low-pressure chiller? - ANSWER-Remove non-
condensable from the system



Which of the following are recommended safe work practices when recovering refrigerants? - ANSWER-
Wear safety eyewear and butyl-lined gloves when connecting/disconnecting hoses



What is the state of the refrigerant leaving the receiver in a refrigeration system? - ANSWER-High
pressure liquid



Which of the following repairs would always be considered "major" under EPA's regulations? - ANSWER-
Replacement of an evaporator coil



On low-pressure chillers, moisture most frequently enters the refrigeration system through: - ANSWER-
Leaks from areas with gaskets or fittings



How would you remove moisture from refrigerant in a system? - ANSWER-Use a filter drier

,Where does refrigerant go after it leaves the purge unit of a low-pressure centrifugal system? -
ANSWER-The evaporator



Which refrigerants can be mixed in an appliance? - ANSWER-Refrigerants cannot be mixed



What gas should be used to leak check a system designed for use with R-410A that has been opened for
a major system repair? - ANSWER-Pressurized nitrogen



What is the term for removing refrigerant in any condition from a system and storing it in an external
container without necessarily testing or processing it in any way? - ANSWER-Recovery



What is meant by the term "high efficiency purge unit"? - ANSWER-Purge units that discharge a low
percentage of refrigerant with the air they remove



Before beginning a refrigerant recovery procedure, it is ALWAYS necessary to: - ANSWER-know the type
of refrigerant in the system



Which of the following gases is used as the baseline measurement for global warming potential? -
ANSWER-Carbon Dioxide



Which hydrocarbon refrigerant is approved for retrofit into existing household refrigerators? - ANSWER-
HC R-600a 2 ounces or less



Recovered refrigerant may contain which of the following impurities? - ANSWER-Acids, moisture, and oil



A hydrostatic tube test kit will - ANSWER-determine if a lube leaks



When installing any type of access fitting onto a sealed system: - ANSWER-the fitting should be leak
tested before proceeding with recovery

, A chiller with a charge of 200 pounds of an ozone-depleting refrigerant has passed the initial verification
leak test. When must a follow-up verification test be conducted? - ANSWER-Within 10 days



Why are some hydrofluoroolefin (HFO) refrigerants classified as "A2L"? - ANSWER-They are less
flammable than hydrocarbon refrigerants, but most are still mildly flammable



To determine if the system is leaking more than the allowed rate, the EPA allows the use of which one of
the following methods to determine the full charge? - ANSWER-Use of calculations based on component
and pipe sizes



When could a reciprocating compressor be damaged if energized? - ANSWER-When the discharge
service valve is closed



Which of the following are included in EPA's definition of a "small appliance"? - ANSWER-Products
manufactured, fully charged and hermetically sealed in a factory



Recovering refrigerant from a system in the vapor phase will minimize the loss of which of the
following? - ANSWER-Oil



Which of the following is an indicator of a leak in a high-pressure system with a capillary tube? -
ANSWER-Excessive superheat



A typical setting for the high-pressure cut-out control on a recovery unit used for evacuating the
refrigerant from a low-pressure chiller is: - ANSWER-10 psig



When is it essential to take measures to help release trapped CFC, HCFC, or HFC refrigerant from the
compressor oil during refrigerant recovery? - ANSWER-When using self-contained recovery devices



Excessive running of a purge system on a low-pressure chiller generally indicates what condition? -
ANSWER-Leaking system



Which of the following always falls under the EPA definition for "major maintenance, service, or repair"?
- ANSWER-Replacing a compressor

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller examiner356. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72841 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart