Sectional images are obtained from all of the following except:



tomography

transverse axial tomography

conventional radiography

computed tomography - correct answer ✔✔conventional radiography



data acquisition refers to:



collecting x-ray transmission readings from the patient

subjecting data to computer processing

changing the data before they are displayed on a monitor

storing the data collected from the patient onto magnetic tapes or disks - correct answer ✔✔collecting
x-ray transmission readings from the patient



which of the following refers to modifying computed tomographic data to make the images more useful
to the observer?



image manipulation

image reconstruction

data collection

pattern recognition - correct answer ✔✔image manipulation



When a large set of transmission measurements is collected from the patient at different locations and is
used to build up an image of internal anatomy, it is referred to as:



tomography

,image reconstruction from projections

pattern recognition

digital image processing - correct answer ✔✔image reconstruction from projections



all of the following apply to CT except:



a computer is used to reconstruct cross-sectional images of the patient

mathematical methods are used to reconstruct images

x-ray film is used as the detector

special detectors are used to detect x-rays that have passed through the patient at multiple angles. -
correct answer ✔✔x-ray film is used as the detector



through the patient is:



attenuation

the relative transmission value

the natural logarithm

the linear attenuation coefficient - correct answer ✔✔attenuation



which of the following refers to the size, shape, motion, and path traced by the x-ray beam as it scans the
patient?



beam geometry

projection profile

data acquisition

detector tracing - correct answer ✔✔beam geometry



a single ray in computed tomography is:

, a beam of x-rays emanating from the x-ray tube

a single straight line path of an x-ray beam

the total attenuation as measured by the detector

a collection of beams gathered by the detector - correct answer ✔✔a single straight line path of an x-ray
beam



computed tomography detectors generate a signal that represents the attenuation as the ray moves
across the slice. This signal is called:



a view sample

an acquisition sample

a profile

a data sample - correct answer ✔✔a profile



Which computed tomography scanner is based on a fan beam geometry and complete rotation of the x-
ray tube and detectors?



first-generation scanner

second-generation scanner

third-generation scanner

fourth-generation scanner - correct answer ✔✔third-generation scanner



fourth-generation computed tomography scanners are characterized by:



rotate-translate motion and parallel beam geometry

rotate-translate motion and fan beam geometry

fan beam geometry and continuous rotation of x-ray tube and detectors

fan beam geometry and complete rotation of x-ray tube around a stationary ring of detectors - correct
answer ✔✔fan beam geometry and complete rotation of x-ray tube around a stationary ring of detectors

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller BravelRadon. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $19.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62890 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$19.99
  • (0)
  Add to cart