ARDMS SPI Review Exam Questions With Correct Answers Example of nonspecular reflector - ANSWER- red blood cells What happens to spatial pulse length when frequency increases? - ANSWER- decreases Axial resolution is dependent on? - ANSWER- wavelength Lateral resolution is dependent on? -...

[Show more]

Preview 4 out of 38  pages

  • August 12, 2024
  • 38
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ARDMS SPI
  • ARDMS SPI
avatar-seller
Stuviaascorers
ARDMS SPI Review Exam Questions
With Correct Answers
Example of nonspecular reflector - ANSWER- red blood cells

What happens to spatial pulse length when frequency increases? - ANSWER-
decreases

Axial resolution is dependent on? - ANSWER- wavelength

Lateral resolution is dependent on? - ANSWER- beam diameter

Where does the beam of an unfocused transducer diverge? - ANSWER- Fraunhofer
zone

Reverberation artifacts are a result of - ANSWER- two or more strong reflecting
surfaces

True/False: Grating lobes are essential for the proper operation of a linear phased
array. - ANSWER- False

True/False: Electronically steered scanners always produce higher resolution images
than do mechanically steered scanners. - ANSWER- False

True/False: An annular array scanner uses mechanical beam steering. - ANSWER-
True

True/False: A linear sequenced array cannot be dynamically focused. - ANSWER-
False

registration or B-mode alignment - ANSWER- Which AIUM test object function utilizes
all the groups of wires in the AIUM 100 mm test object?

axial resolution - ANSWER- Which AIUM test object function utilizes the A group of
wires in the AIUM 100 mm test object?

lateral resolution - ANSWER- Which AIUM test object function utilizes the B group of
wires in the AIUM 100 mm test object?

dead zone - ANSWER- Which AIUM test object function utilizes the D group of wires in
the AIUM 100 mm test object?

depth calibration - ANSWER- Which AIUM test object function utilizes the C or E groups
of wires in the AIUM 100 mm test object?

,What happens to axial resolution when spatial pulse length is decreased? - ANSWER-
improves

How much will a 3.5 MHz pulse be attenuated after passing through 2 cm of soft tissue?
- ANSWER- 3.5 dB

Propagation speed errors result in - ANSWER- improper axial position

Enhancement is caused by - ANSWER- weakly attenuating structures

The Doppler shift frequency is - ANSWER- directly proportional to the velocity of the
reflector

The number of frames per second necessary for a real-time image to be flicker free is -
ANSWER- more than 15

True/False: The SPTA intensity will always be larger than the SATA intensity. -
ANSWER- True

The intensity of the ultrasound beam is usually greater at the focal zone because of -
ANSWER- the smaller beam diameter

If the amplitude is doubled, the intensity is - ANSWER- quadrupled

The attenuation for soft tissue is - ANSWER- increased with tissue thickness

The acoustic impedance of the matching layer - ANSWER- can be chosen to improve
transmission into the body

True/False: In a pulse-echo system, the quality factor should be made as large as
possible. - ANSWER- False

True/False: The beam diameter is constant in the near zone. - ANSWER- False

The operating frequency is dependent on - ANSWER- thickness of the crystal

The period of an ultrasound wave is - ANSWER- the time of one wavelength

The dynamic range of a system is - ANSWER- the ratio of smallest to largest power
level that the system can handle

True/False: The intensity of an ultrasonic beam can be measured with radiation force
balance. - ANSWER- True

,Increasing the pulse repetition period - ANSWER- increases the maximum depth that
can be imaged

Ultrasound bioeffects - ANSWER- are not confirmed below 100 mW/cm² SPTA

True/False: No refraction can occur at an interface if the media impedances are equal. -
ANSWER- False

True/False: Smaller transducers always produce smaller beam diameters. - ANSWER-
False

True/False: The ultrasound beam profile can be measured with a hydrophone. -
ANSWER- True

True/False: The pulsed-Doppler system yields better depth resolution than the
continuous wave (CW) system. - ANSWER- True

True/False: The gray-scale display was made possible when digital scan converters
replaced analog scan converters. - ANSWER- False

True/False: Videotape recorders operating at 30 frames per second cannot be used
with mechanical real-time units because the fram rate is too slow. - ANSWER- False

True/False: Linear phased array scanners need no form of mechanical focusing
because focusing is performed electronically. - ANSWER- False

True/False: The fram rate of real-time scanners depends on the number of lines used to
form the image. - ANSWER- True

True/False: It is not possible to steer an annular phased array electronically. -
ANSWER- True

True/False: The near zone length should be kept as short as possible. - ANSWER-
False

What percentage of intensity of an ultrasound pulse incident on an interface of 0.25 and
0.75 rayls is reflected? - ANSWER- 25%

Axial resolution can be improved by using - ANSWER- higher frequency transducers

When particle motion of a medium is parallel to the direction of a wave propagation, the
wave being transmitted is called a - ANSWER- longitudinal wave

The wavelength in a material having a wave velocity of 1500 m/s emplying a transducer
frequency of 5 MHz is - ANSWER- 0.3 mm

, The factor that determines the amount of reflection at the interface of two dissimilar
materials is - ANSWER- difference in acoustic impedances

The equation that describes the relationship among propagation, wavelength, and
frequency is - ANSWER- λ = c/ƒ

What three things can occur when an ultrasonic beam reaches the interface of two
dissimilar materials? - ANSWER- reflection, refraction, mode conversion

The acoustic impedance of a material is - ANSWER- equal to the product of density and
velocity

The average velocity of ultrasonic waves in soft tissue is - ANSWER- 1540 m/s

True/False: Receiver-angle values in CW Doppler analysis do not influence the final
Doppler shift. - ANSWER- False

Refraction occurs because of difference in ______ across an interface between two
materials - ANSWER- wave velocity

Reflection factor at an interface between two materials depends primarily on the change
in ______ across the interface. - ANSWER- acoustic impedance

The velocity of sound waves is primarily dependent on - ANSWER- medium and mode
of vibration

Increasing the frequency of an ultrasonic longitudinal wave will result in ______ in the
velocity of that wave. - ANSWER- no change

The change in direction of an ultrasonic beam, when it passes from one medium to
another, in which elasticity and density differ from those of the first medium is called -
ANSWER- refraction

A long near zone can be obtained by - ANSWER- using a higher frequency transducer

If a 2 MHz frequency is used in human soft tissue, the wavelength is approximately -
ANSWER- 0.75 mm

The ratio of particle pressure to particle velocity at a given point within the ultrasonic
field is - ANSWER- impedance

What is the following formula used to determine?
(2 × velocity of reflector × original frequency) / velocity of sound - ANSWER- Doppler
shift frequency

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Stuviaascorers. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.79. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

73314 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.79
  • (0)
  Add to cart