100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Residential Electrician Exam 3 | Newest Revised Edition | Latest 2024/25 $11.99   Add to cart

Exam (elaborations)

Residential Electrician Exam 3 | Newest Revised Edition | Latest 2024/25

 6 views  0 purchase
  • Course
  • Residential Electrician
  • Institution
  • Residential Electrician

Residential Electrician Exam 3 | Newest Revised Edition | Latest 2024/25

Preview 2 out of 5  pages

  • August 15, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Residential Electrician
  • Residential Electrician
avatar-seller
STUVATE
Residential Electrician Exam 3 | Newest
Revised Edition | Latest 2024/25
What is the MAXIMUM allowable cord length for the cord supplying a cord-and-plug
connected dishwasher installed under a kitchen counter in a dwelling unit?
a) 11⁄2 feet
b) 2 feet
c) 3 feet
d) 4 feet - D: 4 feet
Ref: 422.16(B)(2)(2)

What is the MINIMUM size copper SE cable with type THHW insulation that may be
used as ungrounded, service-entrance phase conductors for a 150 ampere-rated,
120/240-volt, singlephase, residential service?
a) 1/0 AWG
b) 1 AWG
c) 2 AWG
d) 3 AWG - B: 1 AWG
Ref: Tbl. 310.15(B)(6)

For outlet boxes designed to support ceiling-suspended (paddle) fans that weigh more
than _____ pounds, the required marking shall include the maximum weight to be
supported.
a) 20
b) 30
c) 35
d) 70 - C: 35
Ref: 314.27(D)

A connection to a driven or buried grounding electrode shall ______.
a) be accessible
b) not be required to be accessible
c) not permitted to be buried
d) be visible - B: not be required to be accessible
Ref: 250.68(A), Ex.1

What is the MAXIMUM allowable standard size circuit breaker rating that may be used
to protect a size 8 AWG copper NM-B cable supplying an electric range?
a) 30 amperes
b) 40 amperes
c) 50 amperes
d) 60 amperes - B: 40 amperes
Ref: 334.80; Tbl. 310.16

, The MAXIMUM number of size 10 AWG conductors permitted in a 4 inch x 11⁄4 inch
octagon metal junction box is _____.
a) two
b) four
c) five

d) six - C: five
II II II II II II



Ref: Tbl. 314.16(A)
II II




Determine the MINIMUM number of 15-ampere, 120-volt general lighting branch-circuits
II II II II II II II II II II



required for a dwelling that has 2,600 square feet of habitable space.
II II II II II II II II II II II II



a) three
II



b) four
II



c) five
II



d) six - C: five
II II II II II II



Ref: 220.12; Tbl. 220.12
II II II



Sol:
2,600 sq. ft. x 3 VA = 7,800 VA (total lighting VA of house)
II II II II II II II II II II II II II



120 volts x 15 amperes = 1,800 VA (one circuit)
II II II II II II II II II



7,800 VA (house)/1,800 VA (one circuit) = 4.3 = 5 circuits
II II II II II II II II II II




When calculating the total load on a dwelling unit, how many VA per square feet must be
II II II II II II II II II II II II II II II II II



included for the general purpose receptacle outlets?
II II II II II II II



a) none
II



b) oneII



c) two
II



d) three - A: none
II II II II II II



Ref: 220.14(J)(1)
II




When calculating the total load for a dwelling unit, what is the MINIMUM load, in VA, that
II II II II II II II II II II II II II II II II II



must be added for the two required small appliance branch-circuits?
II II II II II II II II II II



a) 1,200 VA
II II



b) 1,500 VA
II II



c) 2,400 VA
II II



d) 3,000 VA - D: 3,000 VA
II II II II II II II II



Ref: 220.52(A) II



Sol:
1,500VA x 2 circuits required = 3,000VA II II II II II II




It shall be permissible to apply a demand factor of _____ percent to the nameplate-rating
II II II II II II II II II II II II II II II



load of four or more fastened in place electric water heaters in a multi-family dwelling unit.
II II II II II II II II II II II II II II II II



a) 50 II



b) 75 II



c) 80II



d) 90 - B: 75
II II II II II II



Ref: 220.53 II

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller STUVATE. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79373 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.99
  • (0)
  Add to cart