100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
NCIDQ IDFX IDPX Exam Practice Questions & Answers 2024/2025 $8.99   Add to cart

Exam (elaborations)

NCIDQ IDFX IDPX Exam Practice Questions & Answers 2024/2025

 7 views  0 purchase
  • Course
  • NCIDQ IDFX IDPX
  • Institution
  • NCIDQ IDFX IDPX

NCIDQ IDFX IDPX Exam Practice Questions & Answers 2024/2025 When estimating how much fabric will be required for custom designed draperies, which of the following will you need to consider when determining the total fabric width needed? A the amount of fullness of the drapery, the opening siz...

[Show more]

Preview 2 out of 14  pages

  • August 17, 2024
  • 14
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • NCIDQ IDFX IDPX
  • NCIDQ IDFX IDPX
avatar-seller
Bensuda
NCIDQ IDFX IDPX Exam Practice
Questions & Answers 2024/2025

When estimating how much fabric will be required for custom designed draperies, which of the following
will you need to consider when determining the total fabric width needed?

A the amount of fullness of the drapery, the opening size

B the opening size, the amount of fullness, the return

C the return, the opening size, the stacking space

D all of these - ANSWERSD. all of these // In estimating fabric for draperies, the total fabric width must
be determined. This is the total of the opening size, the stacking space, the return, any overlap of two
sections of drapery, and the amount of fullness of the drapery.



What is the maximum height of an accessible (barrier free) sink?

36" (900 mm)

34" (865 mm)

30" (750 mm)

27" (685 mm) - ANSWERSB. 34" // NCIDQ 5.2 ALL accessible (barrier-free) countertops, sinks,
reception/transaction surfaces, and other horizontal work surfaces MUST NOT exceed 34″ (865 mm) AFF
with a 27″H (685 mm) clear knee space below.



ADA.gov 606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or
counter surface 34 inches (865 mm) maximum above the finish floor or ground.



306.3.3 Minimum Required Depth. Where knee clearance is required under an element as part of a clear
floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above
the finish floor or ground, and 8 inches (205 mm) deep minimum at 27 inches (685 mm) above the finish
floor or ground.



A $OSS switch indicates what?

daylight sensor

, remote controlled switch

one single switch

occupancy sensor/switch combination - ANSWERSD. occupancy sensor/switch combination // Refer to
your drawing legend, as symbols used may vary from what you are accustomed to, and could possibly
vary from test to test. This is the symbol provided on a typical NCIDQ drawing that indicates occupancy
sensor/switch combination.



What is minimum clear width of the doorway and maximum size of an egress door?

34 clear width and 36 door leaf

32 clear width and 48 door leaf

34 clear width and 48 door leaf

30 clear width and 36 door leaf - ANSWERSB. 32 clear width and 48 door leaf // International Building
Code 1008.1.1 Size of doors. The minimum width of each door opening...shall provide a clear width of 32
inches (813 mm). Clear openings of doorways with swinging doors shall be measured between the face
of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a
minimum clear width of 32 inches (813 mm) one leaf shall provide a clear opening width of 32 inches
(813 mm). The maximum width of a swinging door leaf shall be 48 inches (1219 mm) nominal.



When selecting the upholstery and window treatment fabrics for a hotel lobby design, which of the
following standards would NOT be a consideration for the fabric?

Cigarette Ignition Resistance Test of Furniture components

NFPA 257

Vertical Ignition Test

Cal TB 116 - ANSWERSB. NFPA 257 // All of these tests relate to the flammability of fabrics with the
exception of NFPA 257, the Standard for Fire test for window and glass block assemblies.



This fire and hose stream test establishes fire protection, in units of time, for window openings in fire-
resistive walls. It determines the degree of protection from the spread of fire, including flame, heat and
hot gases.



Designing sustainable commercial interiors can benefit businesses in three primary areas to include
social, economic and environmental issues.

Which of the following is not a positive effect achieved in these areas?

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Bensuda. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $8.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

78121 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$8.99
  • (0)
  Add to cart