Fire Inspector Chapter 12 questions with
correct answers.
Which of the following is a single-stage fire pump designed to fit into the intake/discharge line with the
driver located above the inline impeller? (534) ANS - Vertical inline



Fire loss data reveals that in buildings equipped with automatic sprinklers, about _____ percent of all
fires were controlled or extinguished by the sprinkler system. (504) ANS - ninety-four



For which fire pump are the impellers actually located within the water supply source? (534) ANS -
Vertical turbine



Which controller monitors and contains alarms for conditions such as low engine oil pressure and high
engine coolant temperature? (537) ANS - Diesel engine controller



Large buildings having two or more zones require a fire department connection (FDC): (531) ANS - for
each zone.



Which type of sprinkler is recessed and covered with a removable decorative cover plate that releases
when exposed to a specific level of heat? (512) ANS - Concealed



Which of the following is a factor that determines the minimum waterflow required for an automatic
sprinkler system? (508) ANS - Hazard being protected



Which type of sprinkler is designed for fast response in residential occupancies where life safety in the
room of origin is the primary concern? (515) ANS - Residential



Which automatic sprinkler system is continually charged with compressed air and when a sprinkler
activates, the air is released, allowing the water-flow control valve to operate and charge the system
with water? (505) ANS - Dry-pipe sprinkler system



Which of the following is the most common method for driving a fire pump? (535) ANS - Electric motor

, Which of the following is a component of standpipe and hose fire suppression systems? (526) ANS -
Pressure-regulating device



Which type of sprinkler is normally provided in a deluge sprinkler system? (515) ANS - Open



Which are vertical sections of pipe that connect the underground supply to the rest of the piping in the
system? (510) ANS - System risers



Thermally sensitive devices such as fusible links keep most sprinklers closed and when heat from a fire
affects these devices: (504) ANS - sprinklers closest to the fire activate automatically.



Which pressure-regulating device at a hose outlet is preferred for managing excessive pressure and is
considered to be the most reliable method of pressure control? (531) ANS - Pressure-control devices



Which type of sprinkler systems operate when an electronic detector or manual control device is
activated? (504) ANS - Deluge or preaction sprinkler systems



Which classification of standpipe and hose systems is designed to be used by both fire department
personnel and trained building occupants? (526) ANS - Class III



Which fire protection system discharges water over the area or surface of electrical equipment to be
protected through an arrangement of pipes and nozzles? (520) ANS - Water-spray fixed system



Water-mist fire suppression systems are designed to be operated at: (522) ANS - considerably higher
pressures than standard sprinkler systems.



Which classification of standpipe and hose fire suppression systems has both 2½-inch (65 mm) hose
connections and 1½-inch (38 mm) hose connections? (526) ANS - Class III



Which detection and activation device sounds a warning when a sprinkler activates and water begins to
flow? (517) ANS - Waterflow alarm

Written for

Institution
Fire Inspector
Course
Fire Inspector

Document information

Uploaded on
August 17, 2024
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Professorkaylee Stanford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
50
Member since
1 year
Number of followers
5
Documents
9281
Last sold
6 days ago
ON A TIGHT DEADLINE? GET YOUR BEST RESOURCES HERE WITH: PROFESSOR KAYLEE.

Hello am professor KAYLEE!!! Looking for the best study guides and most convenient Exam & answer packages, Assignment guided solutions and more. I have developed a range of study materials that cover all aspects of Courses, Study faster & better. My materials are designed to provide clear and concise explanations of complex concepts, with plenty of helpful examples and practice problems to reinforce your learning. If you find my documents to be helpful, kindly write a review! Refer other learners so that they can also benefit from my study materials." Thank you in advance for your purchase.

Read more Read less
3.4

14 reviews

5
5
4
1
3
4
2
2
1
2

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions