Exam (elaborations)
G-60, G60, F-60 FIRE GUARD, F-60 Study Material Exam Study Questions and Answers Graded A 2024.docx
Institution
F-60 FIRE GUARD
G-60, G60, F-60 FIRE GUARD, F-60 Study Material Exam Study Questions and Answers Graded A
[Show more]
Preview 4 out of 37 pages
Uploaded on
August 18, 2024
Number of pages
37
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Institution
F-60 FIRE GUARD
Course
F-60 FIRE GUARD
$12.49
Also available in package deal from $20.99
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal (1)
1. Exam (elaborations) - F-60 fire guard questions and answers graded a 2024.
2. Exam (elaborations) - G-60, g60, f-60 fire guard, f-60 study material exam study questions and answers grad...
3. Exam (elaborations) - F-60 fire guard exam questions and answers graded a 2024.
4. Exam (elaborations) - F60 fire guard questions and answers graded a 2024.
Show more
G-60, G60, F-60 FIRE GUARD, F-60 Study
Material Exam Study Questions and Answers
Graded A 2024
G-60 .- .(correct .answer) .-Use .of .oxygen .and .flammable .gasses, .or .LPG .or .CNG .for .any .hot .work
COF .exception .- .(correct .answer) .-Torch .operations .for .jewelry
FDNY .permit .- .(correct .answer) .-Storing .using .or .handling .
oxygen .and .flammable .gas
in .excess .of .400scf .(LPG, .CNG .or .scetylene)
oxidizing .gass .in .excess .of .504scf
Portable .LPG .must .not .be .stored .when .the .capacity .of .the .container .is .greater .than? .- .
(correct .answer) .-16.4 .oz
Portable .CNG .containers .must .not .be .stored .then .the .capacity .is .greater .than? .- .(correct .answer) .-
8.7 .SCF
Single .standard .portable .LPG .containers .must .not .exceed? .- .(correct .answer) .-100LBs .in .weight
Single .CNG .containers .must .not .exceed? .- .(correct .answer) .-381 .SCF
LPG .
400 .SCF .is .approximately .- .(correct .answer) .-47 .lbs
,Types .of .FDNY .permits .- .(correct .answer) .-Site .specific .permits .
City .wide .permits
Transportation .permits
Site .specific .permit .can .be? .- .(correct .answer) .-Can .be .permenant .or .temperary
Permanent .permits .are .valid .for .how .long? .- .(correct .answer) .-12 .months .only.
Permits .and .renewals .require .inspection .and .will .expire .adter .twelve .months.
Temporary .permits .may .be .valid .from? .- .(correct .answer) .-
One .day .to .12 .months .depending .on .the .construction .or .operations .needed.
City .wise .permit .duration? .- .(correct .answer) .-30 .days
Hazards .out .end .of .day
Quantity .of .hazardous .material .being .stored(maximum)? .- .(correct .answer) .-5 .gals .gasoline
250 .gals .of .flammable .
300 .gals .combustible .liquid
Transportation .permit .- .(correct .answer) .-FDNY .approved .inspected .displayed .on .vehicle
Hot .work .authorization. .- .(correct .answer) .-
Required .for .any .project .with .hot .work .operation .but .not .issued .by .the .FDNY
Responsible .person .- .(correct .answer) .-Must .be .available .for .inspection .by .any .representative .of .fire
.department .during .and .48 .hours .after .the .work .is .complete.
Fire .guard .- .(correct .answer) .-
Cof .holder .who .is .trained .in .and .responsible .for .maintaijjng .a .fire .watch.
Fire .watch .- .(correct .answer) .-Survailance .of .an .area
Detect .signs .of .early .fire
Raise .alarms .
,Notify .department
Pre .hot .work .check .must .be .conducted .by .the .responsible .person .before .hot .work .is .authorized .at .l
east? .- .(correct .answer) .-Once .per .day
Pre .hot .work .check .daily .and .must .very .the .following .- .(correct .answer) .-
Equipment .working .in .order
Hot .work .is .clear .of .combistibles .and .flammable .solids
Combustible .and .non .combustible .are .protected
Fire .watch .personel .are .assigned
Fire .extinguisher .available
Fire .watch .- .(correct .answer) .-A .fire .watch .must .be .maintained .during .any .hot .work .operation.
The .person .conducting .a .fire .watch .shall .- .(correct .answer) .-Not .have .other .duties
Fire .watch
At .least .one .portable .fire .extinguisher .with .a .- .(correct .answer) .-Minimum .2-A:20-B:C .rating .shall .be
.accessible .within .30ft .from .hot .work
Fire .watch
Exception .roofing .operating .fire .extinguisher .- .(correct .answer) .-3-A .40-B:C
Fire .watch .for .torch .operations .conducted .at .following .locations .by .a .F-60 .fire .guard: .- .
(correct .answer) .-Construction .sites
Buildings .and .structures
, Rooftops
Fire .watch .must .continue .for .- .(correct .answer) .-30 .minutes .after .the .conclusing .of .the .work.
Time .and .record .keeping .requirements
CNG .or .LPG .torch .operations .inspections .- .(correct .answer) .-
First .shall .be .conducted .30minute .after .completion
Second .inspection .1 .hour .after .completion
The .inspection .report .must .be .available .- .(correct .answer) .-
48 .hours .after .work .is .complete .for .fire .department .representative .to .look .over.
Oxygen .cylinder .is .made .of .- .(correct .answer) .-Steel .and .contains .100% .oxygen
Oxy .propane .degrees .- .(correct .answer) .-1,500 .degrees
Acetylene .degrees .- .(correct .answer) .-3000 .degrees
Oxy-acetylene .degrees .- .(correct .answer) .-6000 .degrees
Brazing .and .soldering .temperatures .- .(correct .answer) .-Typically .840 .degrees
Oxy-fuel .torch
Oxygen .storage .pressures .up .to .- .(correct .answer) .-2200 .PSI .(pounds .per .square .inch)
Oxy-fuel .torch
Dangerous .fuel .gas .pressures .- .(correct .answer) .-Above .15 .psi .especially .for .acetylene
Gas .torches .also .have .applications .and .additions .like .- .(correct .answer) .-For .burning .weeds
Melting .ice
Applying .tar/asphalt
Backfire .- .(correct .answer) .-Flame .on .torch .goes .out .unexpectedly