100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
FDNY Z51 WRITTEN EXAM ACTUAL EXAM 2 VERSIONS (VERSION 1AND 2) COMPLETE 400 QUESTIONS WITH DETAILED VERIFIED ANSWERS / ALREADY GRADED A+ $17.99   Add to cart

Exam (elaborations)

FDNY Z51 WRITTEN EXAM ACTUAL EXAM 2 VERSIONS (VERSION 1AND 2) COMPLETE 400 QUESTIONS WITH DETAILED VERIFIED ANSWERS / ALREADY GRADED A+

 9 views  0 purchase
  • Course
  • FDNY Z51
  • Institution
  • FDNY Z51

FDNY Z51 WRITTEN EXAM ACTUAL EXAM 2 VERSIONS (VERSION 1AND 2) COMPLETE 400 QUESTIONS WITH DETAILED VERIFIED ANSWERS / ALREADY GRADED A+

Preview 3 out of 29  pages

  • August 19, 2024
  • 29
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • FDNY Z51
  • FDNY Z51
avatar-seller
Americannursingaassociation
FDNY Z51 WRITTEN EXAM ACTUAL EXAM 2
VERSIONS (VERSION 1AND 2) COMPLETE 400
QUESTIONS WITH DETAILED VERIFIED ANSWERS /
ALREADY GRADED A+


VERSION 1
The efficiency of the refrigerant cycle is affected by the operation of the condenser. of
the following. a more efficient centrifugal compressor operation results from: -
ANSWERLowering the condensing pressure

The heat removed from the refrigerant in a condenser is: - ANSWERSensible and latent
heat

The refrigerant unit that you have been assigned to is being taken out of service for a
major repair. you have been assigned to withdraw refrigerant for storage in suitable
containers. according to the new York city fire code, you must ensure that the
containers: - ANSWERAre approved by the US department of transportation

Which of the following best describes how the cylinder unloader work? - ANSWERKeep
in the suction valve opened while the compressor is in the return stroke

In most semi hermetic compressors, the suction vapor is used to: - ANSWERCool the
motor

The amount of refrigerant that flows through the orifices of a economizer is determined
by the: - ANSWERDifference between the high side and load side pressure

The installation of an inline refrigerant cleaning system is advisable: - ANSWERTo
remove impurities from the system

The type of refrigerant system that is least likely to leak refrigerant into the building
space that are cooled - ANSWERThe indirect system

The suction pressure of a reciprocating compressor is 65PSIG. the discharge pressure
of this compressor is 120PSIG. the atmospheric is 14.7 PSI. the compression ratio for
the given condition is closet to: - ANSWER1.69

A super heated vapor is a ? - ANSWERDry vapor above the saturation temperature

,A refrigerant engineer verifies that a condenser water pump is cavitating. of the
following the most likely cause for this condition is: - ANSWERA faulty cooling tower
water level controller

A centrifugal water pump is known as a lift pump when the: - ANSWERThe water supply
to the pump suction inlet is below the pump level

A TXV is used to maintain constant: - ANSWEREvaporator superheat

The chilled water supply to the building is 55F. if the chiller is being used for human
comfort, should you be concerned about this , and why? - ANSWERYes, this
temperature is too high for human comfort purpose

The packing gland of a centrifugal pump serves to: - ANSWERThe drip part of the
packing gland gives evidence that there is water in the pump

Capacity control of a reciprocating hermetic compressor is typically achieved through -
ANSWEROperation of the hot gas bypass valve

The most important reason to sub-cool the refrigerant in the condenser is to ensure that:
- ANSWERA pure liquid refrigerant will enter the metering device

A refrigeration engineer is logging reading from a reciprocating system. compressor
discharge temperature have dropped significantly and the suction line pressure is high.
which of the following that may be causing this set of condition. - ANSWERAn
expansion valve that is open to wide

A low side float valve is used to maintain: - ANSWERThe level of the refrigerant in the
evaporator

Regarding fire safety, which ASHARE refrigerant safety classification indicates no
flammability and lower the toxicity? - ANSWERA1

When an expansion valve is operating properly, at the end of the evaporator will
contain: - ANSWEROnly superheated vapor

What information is not contained in a material safety data sheet-MSDS? -
ANSWERCost of material

In a steam turbine, what is the function of the kingsbury thrust bearing -
ANSWERMaintain axial positioning of the rotor shaft

A centrifugal water pump is considered to be fully primed when - ANSWERThe pump is
full of liquid

, Copper tubing refrigerant lines must be installed for a new system. it is a well known
service practice that tubing collapses at bends that must be made, the refrigerant
engineer should use - ANSWERLever type tubing bender

A reciprocating compressor is making a knocking sound during operation. if the
refrigerant worn parts are not causing the knocking, what is probably the cause -
ANSWERThe slugging of the liquid refrigerant

In order for a refrigerant to become superheated in a section of the lowside refrigerant
line: - ANSWERWhere no liquid refrigerant is present

All liquid has been recovered from a system to be overhauled, the system -
ANSWERShould not be opened until all vapor has been removed

When a refrigerant engineer uses a portable compressor recovery unit to remove vapor
refrigerant from a refrigeration system the removal rate of the refrigerant will gradually
slow down because - ANSWERThe vapor density is decreasing

You are the engineer running a 2000-ton (steam-driven turbine) centrifugal refrigeration
system, a refrigeration system supplies chilled water to a college campus with multiple
buildings. During the course of making your rounds, you check the 9 cell cooling tower
on the roof. You note the water level in all of the cooling tower cells is very low. Which
one of the following immediate action would take? - ANSWERAdd additional make up
water to cooling tower

A rooftop water cooling tower is connected to a water pump in the building basement
with a 12 inches diameter pipe. with the pump turn off, a pressure gauge at the pumps
inlet show a pressure of 140 PSIG the height of the water column, in feet, would be
closet to. - ANSWER323

What device protects the steam turbine from excessive speed? - ANSWERgovernor
assembly

A refrigeration compressor has failed to turn on. the refrigeration engineer on duty
verifies that the electrical circuit to the motor, including all switches and circuit breakers,
is complete according to recommended service practice, the next item to be checked
would likely be the: - ANSWERTemperature and pressure controls

Refrigerants are characterized by their physical properties included flash point,
refrigeration effect, and others. of the refrigerant in commercial and industrial the
highest latent hear and refrigerant effect is: - ANSWERAmmonia

On what characteristics is ASHRAE refrigerant safety group classification system: -
ANSWERFlammability and toxicity

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Americannursingaassociation. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

73314 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)