100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
Previously searched by you
NERC EXAM, TEST, PRACTICE EXAM AND STUDY GUIDE LATEST ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+$27.99
Add to cart
NERC EXAM, TEST, PRACTICE EXAM AND STUDY GUIDE LATEST ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+
12 views 0 purchase
Course
NERC
Institution
NERC
NERC EXAM, TEST, PRACTICE EXAM AND STUDY
GUIDE LATEST ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
WITH RATIONALES (VERIFIED ANSWERS) |ALREADY
GRADED A+
NERC EXAM, TEST, PRACTICE EXAM AND STUDY
GUIDE LATEST ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
WITH RATIO...
NERC EXAM, TEST, PRACTICE EXAM AND STUDY
GUIDE LATEST 2023-2024 ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
WITH RATIONALES (VERIFIED ANSWERS) |ALREADY
GRADED A+
A 50 MVA rated transformer has 30 MW of load. How many MVARs can flow through the transformer
without exceeding the rating?
A. 50 MVAR
B. 40 MVAR
C. 30 MVAR
D. 80 MVAR - ANSWER-B. 40 MVAR
A balancing authority is responsible for load - interchange - generation balance, which calculated value
reflects that balance?
A. Frequency
B. System Lambda
C. Operating reserves
D. ACE - ANSWER-D. ACE
A transmission line has a net VAR load of 25 MVAR into the line resembles which of these statements?
A. The line is equivalent to an inductor
B. The line is transferring the optimum load
C. The line is nearing voltage collapse
D. The line is equivalent to a capacitor - ANSWER-A. The line is equivalent to an inductor
Frequency of the power system is mainly determined by which factor?
A. Load and generation balance in your balancing authority area
B. Load and generation balance in the interconnection
C. Generation power flowing on the transmission lines
,D. Load requirement of each power system - ANSWER-B. Load and generation balance in the
interconnection
Generator reactive power output increases dynamically under which condition?
A. Low voltage
B. High voltage
C. Transmission line trip
D. Energy and capacity deficiency - ANSWER-A. Low voltage
If interconnection frequency is 59.95 Hz, how do balancing authorities support interconnection
frequency?
A. Remain at current MW output level
B. Increasing MW output
C. Decreasing MW output
D. Increasing excitation on the field windings - ANSWER-B. Increasing MW output
In a power system which type of power is especially critical to support heavily loaded transmission lines
and to have dynamic reserves in preparation for contingency?
A. Reactive power
B. Real power
C. Power flow
D. Apparent power - ANSWER-A. Reactive power
Reactive power is needed to support which type of load?
A. Capacitive
B. Resistive
C. Impedance
D. Inductive - ANSWER-D. Inductive
System inertia is the ability of a power system to:
, A. Increase the speed of the rotation of the units resulting in an increase in system frequency
B. Decrease the speed of the rotation of the units resulting in a decrease in system frequency
C. Oppose changes in frequency due to resistance provided by kinetic energy of the rotating masses
D. All of the above - ANSWER-D. All of the above
The ACE equation must include which metered data in addition to the dynamic schedules, pseudo ties,
actual frequency?
A. Generation
B. Transformers
C. Tie Lines
D. Communications - ANSWER-C. Tie Lines
The load on a power transformer is 40 MW and 30 MVAR. What is the transformer's power factor?
A. 0.80
B. 0.70
C. 0.60
D. 0.50 - ANSWER-A. 0.80
The primary cause of low voltage is:
A. VAR losses associated with heavy power transfers
B. Insufficient generation
C. Insufficient transmission capacity
D. Insufficient shunt reactors in service - ANSWER-A. VAR losses associated with heavy power transfers
What causes real power losses on the bulk power system?
A. Current flow causing heating
B. Load that is not online
C. High cost generation
D. Inefficient heat rates - ANSWER-A. Current flow causing heating
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller 2024newestexams. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $27.99. You're not tied to anything after your purchase.