Exam (elaborations)
Elevator Mechanic exam with correct answers.
Institution
Elevator Mechanic
Elevator Mechanic exam with correct answers.
[Show more]
Preview 4 out of 32 pages
Uploaded on
August 20, 2024
Number of pages
32
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Institution
Elevator Mechanic
Course
Elevator Mechanic
$13.49
Also available in package deal from $46.39
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal (1)
$ 193.86
$ 46.39
14 items
1. Exam (elaborations) - Elevator and escalator exam with correct answers.
2. Exam (elaborations) - Elevator machine room maintenance exam with correct answers
3. Exam (elaborations) - Mechanics exam study guide questions with complete solutions.
4. Exam (elaborations) - Mechanics review -1 questions with complete solutions
5. Exam (elaborations) - Bu2 mechanical system - elevator, escalator, travelator exam with correct answers
6. Exam (elaborations) - 100 elevator final exam with correct answers
7. Exam (elaborations) - Final exam elevator with correct answers
8. Exam (elaborations) - Elevator mechanic exam prep with correct answers
9. Exam (elaborations) - Ca state elevator mechanic study guide questions with complete solutions
10. Exam (elaborations) - Elevator mechanic exam review 2024-2025 questions with complete solutions.
11. Exam (elaborations) - Elevator mechanic exam with correct answers.
12. Exam (elaborations) - Elevator mechanic exam 2024-2025 with complete solutions
13. Exam (elaborations) - Elevator mechanic exam review questions with correct answers
14. Exam (elaborations) - Elevator mechanics review questions with complete solutions
Show more
Elevator Mechanic exam with correct
answers
ASME nn- nncorrect nnanswer-American nnSociety nnof nnMechanical nnEngineers
DOSH nn- nncorrect nnanswer-Division nnof nnOccupational nnSafety nnand nnHealth
LADBS nn- nncorrect nnanswer-Los nnAngeles nnDepartment nnof nnBuilding nnand nnSafety
Alteration nnmade nnto nnconveyance nnshall nncomply nnwith nnASME nnA17.1-204 nnSection nn- nncorrect nnanswer-
8.7
The nnseismic nnsection nnof nnASME nnA17.1-2004 nnand nnalterations nnmade nnto nnconveyances nnmust nnalso
nncomply nnwith nnthis nnsection nn- nncorrect nnanswer-8.4
What nnmust nnbe nnsubmitted nnto nnthe nnapplicable nnDivision nnElevator nnoffice nnprior nnto nnbeginning
nnconstruction nnor nnalterations nnon nna nnconveyance nn
Title nn8 nnSec nn3000 nn- nncorrect nnanswer-Letter nnof nnIntent
When nnshall nnCategory nnOne nnTests nnon nnconveyances nnbe nncompleted nn
Title nn8 nnSec nn3141.6 nn- nncorrect nnanswer-Once nnevery nn12 nnmonths
What nnshall nnbe nnprovided nnon nnall nnconveyances nnregardless nnof nnthe nnexistence nnof nnan nnemergency nnstop
nnswitch
ASME nnA17.1-2004 nn
2.27.1.2 nn- nncorrect nnanswer-Audible nnsignaling nndevice
When nnare nnHoistway nndoor nnunlocking nndevices nnon nnall nnconveyances nnrequired
Title nn8 nnSec nn3141.7
,ASME nnA17.1-2004
2.12.6 nn- nncorrect nnanswer-Prohibited
What nnsection nnshould nnGroup nnIV nnplatform nnlifts nnand nnstairway nnchairlifts nnshall nncomply nnwith nn- nncorrect
nnanswer-ASME nnA18.1-2003
When nnsetbacks nnor nnprojections nnexceed nnthis nnnumber nnof nninches, nnoccur nnin nnthe nnenclosure nnwall, nnthe
nntop nnof nnthe nnsetback nnor nnprojection nnshall nnbe nnbeveled nnat nnan nnangle nnnot nnless nnthan nn75 nndegrees
nnwith nnthe nnhorizontal nn
ASME nnA17.1-2004
2.1.6 nn- nncorrect nnanswer-4 nninches
At nnwhat nnheight nnshall nnthe nnhoistway nnenclosure nnof nna nnGroup nnIV nnelevator nnbe nnUnperforated nn
ASME nnA17.1-2004
2.1.1.2.2 nn- nncorrect nnanswer-79 nninches
For nnelevators nninstalled nnafter nnJune nn5, nn1947, nnthere nnshall nnbe nninstalled nnin nnthe nnpit nnof nneach nnelevator
nnwhere nnthe nnpit nnextends nnbelow nnthe nnsill nnof nnthe nnpit nnaccess nndoor nna nnfixed nnvertical nnladder. nnHow
nnmany nninches nnbelow nnthe nnsill?
ASME nnA17.1-2004
2.2.4.2 nn- nncorrect nnanswer-35 nninches
On nna nnGroup nnIV nnelevator, nnwhat nnis nnthe nnminimum nnpit nnlighting nnillumination nnthat nnshould nnbe
nnprovided nnat nnthe nnpit nnfloor
ASME nnA17.1-2004
2.2.5.1 nn- nncorrect nnanswer-10 nnfc nn(foot nncandles)
For nnGroup nnIV nnelevators nnthat nnare nnnot nnfully nnenclosed, nnhow nnhigh nnof nnprotection nnshould nnbe
nnprovided nnon nnthe nnhoistway nnsides nnthat nnare nnlocated nn59 nninches nnor nnless nnfrom nnelevator nnequipment
nnin nnareas nnaccessible nnto nnother nnthan nnelevator nnpersonnel nn
ASME nnA17.1-2004
2.2.1.3 nn- nncorrect nnanswer-94.5 nninches
,Permanent nnmeans nnshall nnbe nnprovided nnto nnprevent nnthe nnaccumulation nnof nnwhat?, nnin nnthe nnelevator
nnpit
ASME nnA17.1-2004
2.2.2.3 nn- nncorrect nnanswer-Water
In nnplace nnof nna nnsump nnpump, nnwhat nnelse nnshall nnbe nnprovided nnon nnelevators nnequipped nnwith
nnFirefighters' nnEmergency nnOperation
ASME nnA17.1-2004
2.2.2.5 nn- nncorrect nnanswer-Drain
On nna nnGroup nnIV nnelevator, nnhow nnfar nnshall nna nnpit nnladder nnextend nnno nnless nnthan nnhow nnmany nninches
nnabove nnthe nnsill nnof nnthe nnaccess nndoor
ASME nnA17.1-2004
2.2.4.2 nn- nncorrect nnanswer-48 nninches
Where nnpit nnmounted nncounterweight nnbuffers nnare nnused, nna nncounterweight nnguard nnis nnnot nnrequired
nnwhen nnthe nnbottom nnof nnthe nncounterweight nnresting nnon nnits nncompressed nnbuffer nnis nnhow nnmany
nninches nnor nnmore nnabove nnthe nnpit nnfloor
ASME nnA17.1-2004
2.3.2.2
5.10.1.3.2 nn- nncorrect nnanswer-84 nninches
When nnan nnelevator nnrests nnon nnits nnfully nncompressed nnbuffers nnor nnbumpers, nnthere nnshall nnbe nna nnvertical
nnclearance nnof nnnot nnless nnthan nnhow nnmany nninches nnbetween nnthe nnpit nnfloor nnand nnthe nnlowest
nnstructural nnor nnmechanical nnpart, nnequipment, nnor nndevice nninstalled nnbeneath nnthe nncar nnplatform nn
ASME nnA17.1-2004
2.4.1 nn- nncorrect nnanswer-24 nninches
The nnminimum nnbottom nnrunby nnof nnan nnun-counterweighted nnGroup nnIV nnelevators nnshall nnnot nnbe nnless
nnthan nnhow nnmany nninches nnwhere nnthe nnrated nnspeed nnexceeds nn30 nnfpm nn
ASME nnA17.1-2004
, 2.4.3 nn- nncorrect nnanswer-6 nninches
In nnno nncase nnshall nnthe nnmaximum nnbottom nnrunby nnexceed nnhow nnmany nninches nnfor nncars
ASME nnA17.1-2004
2.4.4 nn- nncorrect nnanswer-24 nninches
In nnno nncase nnshall nnthe nnmaximum nnbottom nnrunby nnexceed nnhow nnmany nninches nnfor nncounterweights nn-
nncorrect nnanswer-35 nninches
The nnillumination nnmeasured nnat nnthe nnlanding nnsills nnof nna nnGroup nnIV nnelevator nnshall nnnot nnbe nnless nnthan
nnhow nnmany nnfoot nncandles
ASME nnA17.1-2004
2.11.10.2 nn- nncorrect nnanswer-10 nnfc
What nnminimum nnsize nntraveling nncable nnconductor nnis nnused nnfor nnelevator nnwiring nnother nnthan nnthose
nnsupplying nnlight nnand nncontrol nnequipment nncircuits. nn
14 nngauge nnfor nnlighting nnand nncontrol nnequipment nn- nncorrect nnanswer-20 nngauge
Phase nnI nnfire nnrecall nnand nna nnminimum nnof nnone nnfloor nnoperation nnof nnphase nnII nnfire nnservice nnshall nnbe
nntested nnhow nnoften nnto nnensure nnthe nnsystem nnis nnin nnproper nnworking nnorder nn- nncorrect nnanswer-Monthly
Which nnof nnthe nnfollowing nnelevators nnrequire nn5 nnyr nnload nntest nnto nnbe nnperformed: nnGroup nnII, nnGroup nnIII,
nnGroup nnIV
Title nn8 nnSec nn3071 nn- nncorrect nnanswer-All nnof nnthe nnabove
The nntripping nnspeed nnof nnan nnoverspeed nnvalve nnon nna nnhydraulic nnelevator nnshall nnnot nnbe nngreater nnthan
nnwhat nnpercentage nnof nnthe nnelevator nnoperating nnspeed nnin nnthe nndown nndirection. nnMinimum nnis nn110%
ASME nnA17.1-2004
2.19.4.7.5 nn- nncorrect nnanswer-140 nn% nnMax
What nnis nnthe nnmaximum nnspeed nnallowed nnfor nna nnspring nnbuffer