API 570 ASME SECTION V Combined

A film side IQI can be used for: - ANSinaccessible welds ( unable to hand place a source
IQI)

A dark image of the "B" on a lighter background is ___________________. -
ANSAcceptable

One of the procedural requirements for conducting PT is to address the processing details
for
_________________. - ANSPost-examination cleaning; Pre-examination cleaning; Apply the
penetrant.

Non-aqueous developer shall be applied to a _____________. - ANSdry surface

The accuracy of a piece of magnetizing equipment that is equipped with an ammeter shall
be
verified______________________. - ANSEach year

When using fluorescent penetrant, the examiner shall be in a darkened area for at least
______ minutes prior to performing the examination. - ANS5

A wire IQI shall be placed ___________ the weld, with the wires _________ to the weld. -
ANSonly perpendicular

A field indicator is composed of ________ low carbon steel pie sections, furnace brazed
together. - ANS8

The magnetizing current must be identified on the written MT procedure. - ANStype +
amperage

Certification of contaminants shall be obtained for all PT materials used on ___________. -
ANSAustenitic stainless steels

Black light intensity shall be measured with a______________when conducting fluorescent
PT. - ANSBlack light meter

When should a densitometer be calibrated as a minimum? - ANSEvery 90 days

The location markers required by ASME V are required __________________. - ANSappear
as radiographic images

D.C. yokes may be used for detecting_________________discontinuities, per ASME V? -
ANSSurface

, When coatings are applied to enhance contrast, the procedure must be demonstrated that
indications ______________________. - ANSan be detected through the coating

How many total liquid penetrant techniques are listed in ASME V? - ANS6

Prior to examination, each adjacent surface shall be cleaned within at least ______" of the
area
to be examined. - ANS1"

Water washable penetrant shall be removed with a water spray not exceeding _____ and
_____. - ANSFALSE, T 673.1

The maximum emulsification time shall be: - ANSnone of the above (5, 10, 15 min)

Densitometers shall be calibrated by verification with a calibrated______________. -
ANSStep Wedge Film

When using a hydrophilic emulsifier versus a lipophilic emulsifier and intermediate step that
must be
taken is: - ANSpre-rinsing with water. T 673.2

A welded part is to be radiographed and is 1" thick, with 1/8" reinforcement. What ASTM
wire set IQI should
be used on these radiographs if a source side technique is used: - ANSSet B. T-276, Table
T-233.2

When a PT test cannot be conducted between 50° - 125°F, what must be done, per ASME
V? - ANSThe procedure must be qualified. T-652

The double wall viewing technique is limited to what sizes? - ANS3.5" OD or less.

All PT indications are to be evaluated in accordance with_____________________. -
ANSThe referencing Code section

The scope of the ASME Boiler and Pressure Vessel Code, Section V includes: - ANSHow to
perform NDE to achieve a desired result

SE 797 is applicable to _____________________. - ANSany material in which ultrasonic
waves will propagate at a constant velocity.

What finished surface is required of butt welds for PT examination? - ANSNone of the above
(Smooth surface prepared by grinding; Cosmetically clean acid etched surface; A near white
blast surface.)

An IQI is used on a DWE/DWV. The IQI selection is based on___________. - ANSThe
single wall thickness and weld reinforcement. T-276.2

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Qualityexam. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79271 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.49
  • (0)
  Add to cart