100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
2024 Michigan Mechanical Code Questions and Answers 2024 $14.99   Add to cart

Exam (elaborations)

2024 Michigan Mechanical Code Questions and Answers 2024

 5 views  0 purchase
  • Course
  • Michigan mechanic
  • Institution
  • Michigan Mechanic

2024 Michigan Mechanical Code

Preview 2 out of 7  pages

  • August 24, 2024
  • 7
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Michigan mechanic
  • Michigan mechanic
avatar-seller
julianah420
2024 Michigan Mechanical Code

Welded - answerA mechanical joint is not ________ .

make up air - answerAny combination of outdoor and transfer air intended to replace
exhaust air and exfiltration is ___________.

duct - answerA tube or conduit utilized for conveying air is a ___________ .

press joint - answerA permanent mechanical joint incorporating an elastomeric seal and
corrosion resistant grip ring is a __________ .

third party certified - answerPlastic pipe, fittings and components shall be ___________
as conforming to NSF 14.

replaced - answerDefective material or parts shall be ___________ or repaired in such
a manner to preserve its original listing.

25 - answerIn bearing partitions, wood studs shall not be cut or notched to a depth
exceeding __________ % of its depth.

18, listed - answerEquipment with an ignition source shall be elevated such that the
ignition source is not less than __________ inches above the garage floor unless the
appliance is _________ as flammable vapor ignition resistant.

6 - answerEquipment shall be suspended a minimum of ________ inches above the
adjoining grade.

22 - answerAttics containing appliances shall be provided with an opening and
unobstructed passageway not less than _________ inches wide.

16, 30 - answerEquipment on elevated structures or roofs above __________ feet
requiring access must be provided with an interior or exterior access that does not
require climbing over obstructions ________ inches high.

R-3 occupancies - answerProviding permanent access to equipment on a roof does not
apply to ____________ .

12 - answerThe clearance reduction methods shown in 308.4.2 shall not be used to
reduce the clearance of solid fuel burning appliances any less than _________ inches.

, 10 - answerOutdoor intake and exhaust openings shall be located a minimum of
_________ feet from lot lines or buildings on the same lot.

100 - answerVariable air volume boxes shall be designed to regulate outdoor air unless
they provide _________ % of outdoor air.

25 - answerMechanical ventilation systems for enclosed parking garages are not
required to operate continuously when a carbon monoxide detector is installed until the
level reaches ________ ppm.

manual or automatic - answerMechanical ventilation systems shall be provided with
________ controls that will operate the system whenever the spaces are occupied.

0.02 - answerThe mechanical exhaust rate for a crawl space shall be not less than
___________ cfm per square foot of horizontal area.

60 - answerCrawl space ventilation must be a minimum 0.02 cfm per square foot and
shall be automatically controlled to operate when the humidity exceeds ___________ %

outdoors, nuisance - answerThe air removed by every exhaust system shall be
discharged _____________ and at a point where it will not cause a ____________.

whole house ventilation type - answerOnly _________ fans can discharge their exhaust
into the attic of dwelling units that have private attics.

6 - answerFlammable finish exhaust duct terminations shall be a minimum
___________ feet from exterior walls and roofs.

1 - answerThe exhaust rate for hazardous materials stored in excess of the maximum
allowable quantity shall be provided at a rate of not less than __________ cfm/ft2 of the
storage floor area.

200 - answerClothes dryers exhausting more than ________ cfm requires make up air.

35 - answerThe maximum length of a clothes dryer duct is ___________.

outside of the airstream - answerCommercial type clothes dryers require the fan motors
be located ____________.

18 - answerThe grease duct clearance required when located within a shaft enclosure is
_________ inches to the combustible construction.

40 - answerType I exhaust outlets shall discharge a minimum of _________ inches
above the roof.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

73243 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.99
  • (0)
  Add to cart