100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
NFPA 10 EXAM ACTUAL EXAM COMPLETE 250 QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY GRADED A+ $17.99   Add to cart

Exam (elaborations)

NFPA 10 EXAM ACTUAL EXAM COMPLETE 250 QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY GRADED A+

 5 views  0 purchase

NFPA 10 EXAM ACTUAL EXAM COMPLETE 250 QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY GRADED A+

Preview 3 out of 17  pages

  • September 7, 2024
  • 17
  • 2024/2025
  • Exam (elaborations)
  • Unknown
All documents for this subject (1)
avatar-seller
Americannursingaassociation
NFPA 10 EXAM ACTUAL EXAM COMPLETE 250
QUESTIONS WITH DETAILED VERIFIED ANSWERS
(100% CORRECT ANSWERS) /ALREADY GRADED A+



Test pressure gauges shall be certified accurate to ___ percent or better of the full
range of the gauge. - ANSWER+/- .5

Test pressure gauges shall be capable of indicating ___ percent of the test pressure. -
ANSWER90-110

Pressure gauges used on TEST EQUIPMENT shall be calibrated at least ___. -
ANSWERSEMI-ANNUALLY

Master gauges or deadweight testers shall be calibrated at least ___. -
ANSWERANNUALLY

The temperature for drying shall not exceed ___. - ANSWER150F

Cylinders and hose assemblies shall be tested within a protective cage device or placed
behind a protective shield that permits ___ observation while under pressure for leaks
bulges and other harmful defects. - ANSWERVISUAL

A hydrostatic test pump, hand- or power-operated, shall be capable of producing not
less than ___ percent of the test pressure and shall include appropriate check valves
and fittings. - ANSWER150

A ___ connection between the test pump and the test cylinder shall be provided so that
it is possible to test through the cylinder opening, test bonnet, hose outlet, or nozzle, as
applicable. - ANSWERFLEXIBLE

Hydrostatic test intervals (WETTING agent). - ANSWER5 years

Hydrostatic test intervals (dry chemical with stainless steel shells). - ANSWER5 years

Hydrostatic test intervals (carbon dioxide). - ANSWER5 years

Hydrostatic test intervals (dry chemical cartridge or cylinder operated with mild steel
shells). - ANSWER12 years

Hydrostatic testing intervals (Dry chemical, stored-pressure, with mild steel shells,
brazed brass shells, or

,aluminum shells). - ANSWER12 years

The hydrostatic retest shall be conducted within the ___ of the specified test interval. -
ANSWERCALENDAR YEAR

Nitrogen cylinders, argon cylinders, carbon dioxide cylinders or cartridges used for inert
gas storage that are used as expellants for wheeled fire extinguishers and carbon
dioxide extinguishers shall be hydrostatically tested every? - ANSWER5 YEARS

Cylinders except those charged with carbon dioxide complying with 49 CFR 180.209B
shall be permitted to be hydrostatically tested every ___ in lieu of the requirements. -
ANSWER10 YEARS

Nitrogen cartridges, argon cartridges and carbon dioxide cartridges used as expellants
for hand portable fire extinguishers that have ___ or ___ markings shall be hydrostatic
test and replaced. - ANSWERDOT or TC

DOT 3E cartridges or TC 3EM cartridges shall be ___. - ANSWERexempt from periodic
testing

A ___ test shall be performed on fire extinguisher hose assemblies equipped with a ___
nozzle at the end of the hose. - ANSWERHYDROSTATIC, SHUTOFF

High pressure and low pressure accessory hose other than agent discharge hose used
on wheeled extinguishers shall be ___ tested. - ANSWERHYDROSTATICALLY

If, at any time, a fire extinguisher shows evidence of dents, mechanical injury, or
corrosion to the extent as to indicate weakness, it shall be ___ or ___ retested. -
ANSWERCondemned, hydrostatically

Nonrechargeable HALON agent-type fire extinguishers that show evidence of dents,
mechanical injury, or corrosion to the extent indicating weakness shall be removed from
service, shall not be discharged, and shall be returned to the manufacturer, a fire
equipment dealer, or ___ to promote recovery of the Halon. - ANSWERDISTRIBUTOR

Where repairs by soldering, welding, brazing, or use of patching compounds exist. -
ANSWERShall be condemned or destroyed by owner or owners direction

Where the cylinder threads are worn, corroded, broken, cracked, or nicked. -
ANSWERShall be condemned or destroyed by owner or owners direction

Where the fire extinguisher has been exposed to excessive heat flame or fire. -
ANSWERShall be condemned or destroyed by owner or owners direction

, Where a CALCIUM CHLORIDE-type extinguishing agent has been used in a stainless
steel fire extinguisher. - ANSWERShall be condemned or destroyed by owner or owners
direction

Where the depth of a dent exceeds 1/10 of the greatest dimension of the dent if not in a
weld or exceeds a quarter inch if the dent includes a weld. - ANSWERShall be
condemned or destroyed by owner or owners direction

The pressure in a hydrostatic test of a cylinder shall be maintained for a minimum of
___ seconds, but for a time not less than is required for complete expansion of the
cylinder and to complete the visual examination of the cylinder. - ANSWER30

All valves internal parts and hose assemblies shall be ___ and the fire extinguisher shall
be ___ before testing. - ANSWERREMOVED, EMPTIED

All types of extinguishers except the water type shall have all traces of a extinguishing
agents ___ from the inside of the extinguisher before they are filled with water. -
ANSWERREMOVED

All tests shall be conducted using ___ fittings and ___. - ANSWERTEST, ADAPTERS

The hydrostatic testing of dry chemical and dry powder fire extinguishers having an
externally mounted Gas cartridge shall have the cartridge and cartridge receiver
removed and a ___ inserted into the opening. - ANSWERPLUG

All stored pressure extinguishers shall have the valve removed from the cylinder and
replaced with a ___ or ___. - ANSWERTEST BONNET, ADAPTER

Any ___ of the cylinder shall be cause for ___. - ANSWERdistortion, rejection

A drop in pressure of the test gauge which is an indication of a ___ shall be cause for
rejection or retest. - ANSWERLEAK

Cylinders passing the hydrostatic test shall be ___ before being returned to service. -
ANSWERThoroughly dried internally

The discharge valve shall be removed from the hose assembly without ___ of any hose
couplings - ANSWERREMOVAL

The location of all ___ shall be ___ prior to the hydrostatic test. -
ANSWERCOUPLINGS, MARKED

The host shall be completely filled with ___ before testing. - ANSWERWATER

For dry chemical and dry powder types, all traces of dry chemical or dry powder? -
ANSWERShall be removed prior to testing

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Americannursingaassociation. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62555 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart