What is considered a normal box temperature of a walk-in refrigerator - Answer-35-38F What is considered a normal box temperature for a reach in refrigerator - Answer-38-40F What is considered a normal box temperature of a walk-in freezer - Answer--10F What is considered a normal box tempe...

[Show more]

Preview 2 out of 7  pages

  • September 10, 2024
  • 7
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Refrigeration machine operator
  • Refrigeration machine operator
avatar-seller
lectknancy
Refrigeration test Exam Questions with
Complete Solutions
What is considered a normal box temperature of a walk-in refrigerator - Answer-35-38F

What is considered a normal box temperature for a reach in refrigerator - Answer-38-
40F

What is considered a normal box temperature of a walk-in freezer - Answer--10F

What is considered a normal box temperature for a reach in freezer - Answer-0 degrees
Fahrenheit

How can latent heat in a suction line be transferred to a higher outdoor temperature -
Answer-Compress the suction vapor until its condensing temperature is higher than the
ambient.

Why do zeotropic blends have temperature glide - Answer-do not have a common
boiling point for all the constituents.

Under what circumstances should a technician use TROT - Answer-When factory
information is not available.

If the condensing temperature is 125F and the evaporator temperature is 25F what
refrigerants are being used - Answer-R404A?

What is considered to be evaporator temperature - Answer-The temperature of the
refrigerant inside the evaporator tubing.

How do you calculate evaporate temperature from the suction pressure - Answer-Use a
PT chart

How is evaporator temperature difference calculated for a walk-in cooler - Answer-
Subtract the SST from the box temperature.

What is a hot pull down - Answer-a condition in which the refrigerator has difficulty
removing heat from the box.

During hot pull down what is the evaporator experiencing - Answer-the evaporator coil
starves

As TD increases how does it affect box humidity - Answer-It decreases

, If airflow across the evaporator decreases what effect does it have on the evaporator
temperature and suction pressure - Answer-both decrease.

Why are multiple circuits used on a large evaporator coil - Answer-They provide less
pressure drop than a long single circuit evaporator.

How do you determine the evaporator superheat of a refrigeration system - Answer-
Subtract evaporator temperature from the temperature of the suction line at the
expansion valve bulb.

A 10F walk in freezer using r404A has a suction pressure of 15 psig. The suction line
temperature at the txv bulb is -20F what is the evaporator superheat. - Answer-The
evaporator superheat in the given scenario is 10ºF

A superheat below 5F indicates the evaporator is experiencing which of the following -
Answer-over charged with refrigerant by the metering device

How many degrees of box temp can you check superheat - Answer-5 degrees

Why is it necessary for the fin spacing in a freezer evap to be wide - Answer-Frost
buildup will not occur as fast if the fin spacing is wide

WHat is the basic sequence of operation at the beginning of a freezer defrost - Answer-
Evaporator fans shut off, compressor shuts off, and heaters come on.

What is the primary function of the condenser? - Answer-to transfer heat from the
refrigerant to another medium, such as air and/or water.

Why does the suction vapor have to be increased in temp before it can be condensed -
Answer-the extra heat provides the molecules with more energy, allowing for a higher
pressure that enables the vapor to condify when cooled

How can the temp of refrigerant be increased without any excess of heat - Answer-By
increasing the pressure

What are the 3 phases of the condenser - Answer-desuperheating, condensation and
sub-cooling.

Where does the SH in discharge gas come from - Answer-Suction vapor heat,
compressor motor heat, and heat of compression

Where does the SH in added heat come from - Answer-any temperature of the vapor
above the saturation temperature

What happens inside the compressor - Answer-Converts gas

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller lectknancy. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79271 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart