For a given conductor size, which material has the greatest ampacity? - Answer -copper
only

Conductor sizes up through 4/0 AWG are expressed in American Wire Gauge (AWG).
Conductor sizes larger than 4/0 AWG are expressed in ____. - Answer -kcmil

The ampacity of the conductors in nonmetallic-sheathed cable is based on that of ____
conductors. - Answer -60°C (140°F)

How is track lighting load in residences calculated? - Answer -It is considered to be part
of the general lighting load of 3 volt-amperes per square foot.

In which location(s) is Type NM cable NOT allowed to be run? - Answer -Both damp
and moist locations and when concealed in dry locations.

The NEC defines a ____ as "the circuit conductors between the final overcurrent device
protecting the circuit and the outlet(s)." - Answer -branch circuit

Which of the following is NOT included when calculating the usable area of a dwelling to
compute the required lighting load? - Answer -crawl space

Where noncombustible surface material is used on walls or ceilings, outlet boxes must
be mounted so that they will be set back not more than ____ from the face of the
surface material. - Answer -1/4 in. (6 mm)

Continuous loads are not permitted to exceed ____ of the rating of the branch circuit. -
Answer -80 %

The National Electrical Code requires outdoor receptacles to be ____. - Answer -GFCI
protected

In the international system of units, the prefix milli- means ____. - Answer -one
thousandth

,Connectors marked ____ are suitable for use with aluminum, copper, or copper-clad
conductors. - Answer -AL/CU only

The rating of a branch circuit is determined by its ____. - Answer -overcurrent protective
device (fuse or circuit-breaker)

A device's primary function is to ____. - Answer -control electric energy

Liquidtight flexible nonmetallic conduit is subject to which of the following limitations? -
Answer -Both of these choices are limitations.

Under certain circumstances, the grounded (neutral) conductors of a residential service
____ permitted to be sized smaller than the phase conductors. - Answer -are

Device faceplates must be mounted so as to ____. - Answer -cover the opening in the
wall and to seat against the wall surface

Type AC cable is manufactured with ____ conductors. - Answer -all of these types of

The general lighting load for a dwelling is based on the ____. - Answer -square footage
of the dwelling

Type ____ is the most common building wire used today. - Answer -THHN/THWN

Wall receptacles must be placed so that no point measured horizontally along the floor
line in any wall space is more than ____ feet from a receptacle outlet. - Answer -6

For safety, it is very important that electrical equipment be "listed" by the ____. - Answer
-NRTL

Branch circuit conductors must have an ampacity ____ the maximum to be served. -
Answer -not less than

The term approved means to be ____. - Answer -acceptable to the authority having
jurisdiction.

In construction of one- and two-family dwellings, the electrical circuits are usually
designed by the ____. - Answer -electrician

Most public service commissions require that the voltage for residential services be held
to ± ____ percent of the nominal voltage as measured at the service point. - Answer -5

Which piece of electrical equipment is NOT considered a device? - Answer -lamp

, A receptacle outlet is a(n) ____. - Answer -outlet where one or more receptacles are
installed

What determines the rating of a branch circuit? - Answer -Rating of the overcurrent
device

An arc flash can produce temperatures of ____°F. - Answer -35,000

The total rating of utilization equipment fastened in place, other than luminaires, is not
permitted to exceed ____ of the branch-circuit rating if the branch circuit also supplies
lighting, other cord-and-plug-connected equipment, or both types of loads. - Answer -50
%

According to ____, unused knockouts and other openings in electrical boxes and
cabinets are required to be closed. - Answer -NEC 110.12(A)

Footwear suitable for electrical work is marked with the letters ____ - Answer -EH

The minimum lighting load requirement for dwellings is ____ volt-amperes per square
foot. - Answer -3

Low voltage (high voltage drop) in a home can be caused by ____. - Answer -All of
these choices

Electrical wall boxes should not be mounted back-to-back in walls because ____. -
Answer -All of these choice

The NEC in Table 210.24 shows that the minimum conductor size for branch-circuit
wiring is ____. - Answer -14 AWG

A dual-rated conductor marked THHN/THWN is rated ____ when used in dry locations.
- Answer -90°C (194°F)

In the international system of units, the prefix kilo- means ____. - Answer -thousand

When a 4 ft. piece of nonmetallic-sheathed cable is used as a fixture whip above an
accessible ceiling, it ____. - Answer -is not required to be secured

As defined in Article 100, a dwelling unit has the following feature(s): ____. - Answer -
permanent provisions for living, sleeping, cooking, and sanitation

For continuous loads, the branch-circuit rating, the conductors, and the overcurrent
device are required to be not less than ____ of the rating of the equipment. - Answer -
125 %

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller millyphilip. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62890 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart