BPI-1200 Test Questions and Answers

2.0 General requirements - main purpose - Correct Answers -Obtain relevant
operational information to supplement asset-based data.

What document does the the BPI-1200 parallel? - Correct Answers -The standard
parallels a ANSI/BSR BPI-1100-T-201X

2.0 General requirements - what is Annex B - Correct Answers -Sample of
homeowner/occupant questionnaire

3.4 Health and safety related requirements - Correct Answers -A citizens guide to
radon, US EPA

3.5 BPI Auditor as electrician - Correct Answers -The auditor shall limit any electrical
recommendations to the identification of knob and tube wiring and other visual
observations such as frayed or exposed wiring.

3.5 BPI Auditor if trained as electrical technician - Correct Answers -May limit any
electrical recommendations for which they have been trained

4.0 disclosure and ethics - Correct Answers -The auditor shall disclose any current or
potential conflicts of interest of the auditor to the customer

5.0 cost benefit analysis - Correct Answers -As part of the evaluation process shall
conform to the requirements of ANSI/BSR BPI-1100-T-201X Home energy auditing
standard, section 5

6.0 prioritizing recommendations - Correct Answers -Shall conform to the requirements
of ANSI/BSR BPI-1100 T-201X, section 6

7.0 Combustion Appliance & Fuel Distribution System Inspection - Correct Answers -
Shall include inspection of combustion appliances and fuel distribution systems for
safety problems.

7.1 Gas Leaks, and/or actionable CO Levels - Correct Answers -Identify and
communicate situations that may require health and safety remediation items such as:

,7.2.1 CGD = - Correct Answers -Combustion Gas Detector

7.2.2.1 Must be intrinsically safe - Correct Answers -CGD will not cause a spark.

7.2.2.2 Must have an adjustable tick rate - Correct Answers -Does not necessarily
identify hazardous thresholds

7.2.2.3 LEL = - Correct Answers -Lower Explosive Limit, is below .5%/ Air Volume

7.2.2.4 CGD Must be calibrated when, how much - Correct Answers -At least annually,
or per manufactures recommendations

7.2.2.5 CGD shall be labeled with calibration sticker noting what - Correct Answers -At a
minimum the date of last calibration

7.2.2.6 CGD shall have the ability to zero ambient conditions to track leak locations
given - Correct Answers -Is prone to false positives from high humidity

7.2.4 Equipment/instrument used to detect incomplete combustion within ambient air -
Correct Answers -A Carbon Monoxide Detector (CO)

7.2.4.2 What is the CO instrument sensitivity required - Correct Answers -0 to 2000
PPM CO

7.2.4.3 CO Detector should have a resolution of < or = - Correct Answers -1 PPM

7.2.4.4 CO Detector should have an accuracy of +/- - Correct Answers -5 PPM

7.2.4.5 CO Detector must be calibrated when, how much - Correct Answers -CO
Detector is calibrated annually, or per manufactures recommendations

7.2.4.6 After calibration what minimal amt. of information should appear on the sticker -
Correct Answers -The date of last calibration

7.2.4.7 CO Detector can be used for personal protection - Correct Answers -False,
unless stated by manufacturer

7.2.5.1 Auditor shall wear a CO Detector of the type - Correct Answers -Approved by
the manufacturer for personal protection

7.2.5.2 Auditor shall operate &react to a CO Detector - Correct Answers -During an
audit, by creating safe working conditions

7.2.5.6 = - Correct Answers -Additional Equipment Required for Depressurization Tests

7.2.6.1 Smoke pencils are the only piece of equipment need - Correct Answers -False

, 7.2.6.2 Manometer - how many - Correct Answers -One or more are suitable having an
accuracy of 0.1 Pa, and a resolution of +/- 0.2 Pa or better.

7.3 safe entry and working conditions associated with indoor air quality - Correct
Answers -Indoor air environment is found to be safe for their work can be undertaken.

7.3.1 CGD, Personal CO Monitors - how to calibrate - Correct Answers -Calibrate
outside the building away from any combustion outlets or automobile traffic areas, and
in accordance with manufacturers instructions

7.3.2.1 went to vacate the home during an audit - Correct Answers -If at any time out of
your smells combustible fuel gas occupants shall be notified to leave the house

7.3.2.2 CO shall be sampled and what is safe level - Correct Answers -At least one
location of each floor. If carbon monoxide concentration exceed 10% of the LEL
documents and auditor shall leave the house

7.3.2.2 contact emergency services exterior of home and - Correct Answers -Audit shall
not proceed until emergency services have deemed it safe to reenter

7.3.3.1 = - Correct Answers -Carbon monoxide (CO)

7.3.3.1.1 when can work proceed at what concentrations - Correct Answers -Work shall
not proceed when time weighted average carbon monoxide concentrations in the work
environment exceed 50 ppm for one hour and/or 200 ppm for eight hours

7.3.3.2.1 = - Correct Answers -Immediately upon entering building CO measurements
shall be taken in the utility rooms and the occupied spaces.

7.3.3.2.2 = - Correct Answers -Ambient atmosphere safety CO action levels

7.3.3.2.2 actions in response to CO measurements shall be taken in accordance with -
Correct Answers -US consumer product safety commission CPSC document;
responding to residential carbon monoxide the incidence; guidelines for fire another
emergency response personnel.

7.3.3.2.2.1 If the CO instrument indicates an ambient carbon monoxide level of 70 ppm
or greater - Correct Answers -Auditor shall terminate inspection, notify all occupants to
evacuate building, auditor to leave building.

7.3.3.2.2.2 If the CO instrument indicates an ambient carbon monoxide level between
36 ppm and 69 ppm - Correct Answers -Auditor shall advise of high level, recommend
all sources be turned off, open all windows/doors, and if source = CO producing
appliance notify service professional.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller millyphilip. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77016 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.99
  • (0)
  Add to cart