A weld-on patch plate used for repairing a tank bottom shall? correct answersNever be placed over an area of global dishing.
New welds attaching existing shell plates to existing or new shell plates should follow what two inspection methods? correct answersVisual and RT
When a tank bottom is ...
A weld-on patch plate used for repairing a tank bottom shall? correct answersNever be placed over an
area of global dishing.
New welds attaching existing shell plates to existing or new shell plates should follow what two
inspection methods? correct answersVisual and RT
When a tank bottom is removed by using arc-gauging, the areas of the tanks shell-to- bottom weld shall
be? correct answersMagnetic-particle examined and defective areas repaired and re-examined
At what frequency shall visible and fluorescent light meters used with liquid penetrant testing be
calibrated. correct answersA min. of once a year.
Fitness for service evaluations may be used to exempt a repair from hydrostatic testing if performed by
a? correct answersEngineer experienced in tank design and evaluation methodologies used.
Flame arrestors should be inspected when? correct answersAt appropriate intervals.
When corrosion is found on the underside of a tank roof and the top side of the tank shell, structural
members such as roof girders and rafters will most likely be thinning at what rate? correct answersTwice
the rate of the roof or shell.
Assessment of internal tank settlement requires placement of measurement points across the tank
diameter at intervals of not more than? correct answers10 feet
In a API standard 653 repair a replacement plate meets but does not cross a horizontal weld. prior to
welding of a new vertical joint the horizontal weld should be cut beyond the new vertical joint at min.
length of? correct answers12 inches
, Surface prep, anchor patterns typically required for coatings are generally how many mils. deep? correct
answers1.5-4 Mils.
A limitation of PT is that standard penetrant systems are limited to welds having a max temp. of? correct
answers125°F
In calibrating magnetizing equipment ammeter, what is the max deviation allowed relative to the actual
current value as shown by the test meter? correct answers+/- 10%of full scale
The max deposition rate for pulsed arc transfer mode is? correct answersAbout 200 in./min.
Consequence factors to consider in an RBI assessment of a tank include? correct answersMode of failure
The pattern of caustic cracking observed on the steel surface appears sometimes as cracks that? correct
answersHave spider-web appearance initiating at weld flaws.
When a in-service tank inspection is performed, what is the recommended method of documenting
leaks on a riveted shell? correct answersLocate leaks by sketch or photo.
An example of a non-essential variable for a tank bottom scanner qualification test is? correct
answersPlate cleanliness.
The annual cathodic protection surveys for a impressed current system may? correct answersInclude one
or more electrical measurements performed previously in the initial survey.
For tank repairs, safeguards for personal health and safety, and prevention of property damage shall be
developed to the guidelines given in which standard. correct answersAPI 2015 and API 2217A
How far beyond the outer periphery of the foundation ring wall should the drip ring extend? correct
answers3 inches
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller QUILLSKY. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $16.99. You're not tied to anything after your purchase.