ICC Fire Inspector 1 2024 test prep 1 Questions and Answers Fully Solved (1 - 1) Stairways that are part of the means of egress for the exterior provide a minimum clear width of (BLANK) between handrails? D. 48 inches ( IBC 1009.7.4) 1-2 What is the minimum density allowable for foam plast...

[Show more]

Preview 2 out of 6  pages

  • September 24, 2024
  • 6
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Fire Inspector
  • Fire Inspector
avatar-seller
julianah420
ICC Fire Inspector 1 2024 test prep 1
Questions and Answers Fully Solved

(1 - 1) Stairways that are part of the means of egress for the exterior provide a minimum
clear width of (BLANK) between handrails? - answerD. 48 inches ( IBC 1009.7.4)

1-2 What is the minimum density allowable for foam plastic used as interior trim ? -
answerB. 20 Pounds per Cubic Foot (IBC 2604.2.1)

1-3 Group B buildings having an occupant load of (BLANK) or more than 100 persons
above or below the lowest level of exit discharge and for buildings having an ambulatory
care facility are required by the international fire code to have an approved fire safety
and evacuation plan prepared and maintained for this property. - answerC. 500 or more
persons (IFC 403.3 Group B occupancy)

1-4 In assemblies used for structural fire resistance and fire-resistance-related
construction, each portion of a building separated by one or more fire walls that comply
with the provisions of the fire wall section of the code is to be considered (BLANK), and
the extent and location of such fire walls must provide a complete separation. -
answerC. A Separate Building (IBC 706.1)

1-5 In assemblies used for structural fire resistance and fire-resistance-rated
construction, through penetration are to be protected using systems installed as
(BLANK) in the approved fire-resistance-rated assembly. - answerD. Tested (IBC
714.4.1.1)

1-6 Exterior landings outside of egress door are permitted to have a slope which does
not exceed (BLANK) *exceptions ignored* - answerC. 0.25 Unit Vertical in 12 Units
Horizontal. (IBC 1010.1.4)

1-7 Any tower, spire, dome or cupola that exceeds 60 feet in height above the highest
point at which it comes in contact with the roof, or that exceeds 200 square feet in area
at any horizontal section, or which is intended to be used for any purpose other than a
belfry or architectural embellishment, must be entirely constructed of and supported by
noncombustible materials and must be separated from the building below by
construction having a fire-resistance rating of not less than (BLANK) hours. Rating. -
answerA. 1-1/2 hours (IBC 1511.51

1-8 what interior wall and ceiling class finish is required in sprinklered rooms and
enclosed spaces of a Group A-4 Occupancy? - answerC. Class C Finishes (IBC table
803.13)

, 1-9 As to attics and under-floor and concealed spaces used for the storage of
combustible materials (BLANK) *exception ignored* - answerD. Stored items may not
be placed on exposed joists (IFC 315.4

1-10 Fire Department glass access panels are to be made of (BLANK) glass. -
answerB. Tempered (IBC 2406.5

1-11 In motor Fuel-dispensing facilities, dispensers operating instructions must be
conspicuously posted in approved locations (BLANK). - answerD. On every Dispenser
(IFC 2304.2.3)

1-12 open-flame warning devices may not be used along an excavation, road, or any
place (BLANK). - answerC. Where the dislodgment of such device might permit the
device to roll, fall, or slide on to any area or land containing combustible material. (IFC
305.3)

1-13 An area where persons unable to use stairways can remain temporarily to await
instructions or assistance during emergency evacuation. - answerB. Area of refuge (IBC
Chapter 2 Definitions)

1-14 That property of materials or their assemblies that prevents or retards the passage
of excessive heat, hot gases or flames under conditions of use. - answerB. Fire
Resistance (IBC Chapter 2 Definitions)

1-15 Factory Industrial Moderate-Hazard occupancy. Factory industrial uses which are
not classified as Factory Industrial (BLANK) will be classified as (BLANK). - answerC. F-
2 Low Hazard, F-1 Moderate Hazard (IBC 306.2)

1-16 The IFC requires that fire drills be held at unexpected times and under varying
conditions to simulate the unusual conditions that occur in case of fire. At what
frequency does the international Fire Code require drills to be held for Group I-1
occupancy situations? - answerC. Semiannually on each shift (IFC Table 405.3)

1-17 To ensure operational readiness and proper performance, fire detection and alarm
signaling systems must be tested when they are installed and again on a continuing
basis. Tests conducted when systems are installed are commonly called (BLANK). -
answerD. Acceptance Test (Fire inspection 7th Edition)

1-18 A(n) (BLANK) has its own source of power and does not depend on the supply
source that powers the entire municipal fire-alarm system. - answerC. Local energy fire-
alarm systems (Fire inspection 7th edition)

1-19 The fire code offical, the fire department or other responsible authority have the
authority to investigate the cause, origin, and circumstances of any fire, explosion or
other hazardous conditions. Information that could be related to (BLANK) or processes

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

52355 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.49
  • (0)
Add to cart
Added