The sensor of the temperature measuring device shall be submerged a minimum of
_____ in. [_____mm] into the freshly mixed concrete. - Answers -3 in. [75 mm]

The temperature measuring device shall have a capacity of measuring temperature of
freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of
_____. - Answers -1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C]

The temperature measuring device shall be calibrated _____, or whenever there is a
question of _____. - Answers -Annually, accuracy

The temperature of concrete may be measured in a wheelbarrow. True or False? -
Answers -True

The temperature of concrete may be measured in a wall form. True of False - Answers -
True

A composite sample of concrete is required even if the only purpose for obtaining the
sample is to determine temperature. True of False? - Answers -False

What must be done to the sample container prior to sampling the concrete? - Answers -
Dampen (with water)

What must be done to the concrete surrounding the temperature measuring device after
the device is submerged in the fresh concrete. - Answers -Gently press the concrete
around the temperature measuring device at the surface of the concrete

How long must the temperature measuring device remain in the freshly mixed concrete?
- Answers -At least 2 minutes but not more than 5 minutes

After the temperature of the concrete is read, what is required? - Answers -Reporting of
temperature

The temperature of concrete is reported to the nearest _____ degrees F [_____ C] -
Answers -1 degree F [0.5 C]

According to ASTM C1064, what is one reason to take the temperature of concrete? -
Answers -Verify conformance to a specified requirement for temperature of concrete

A maximum temperature of freshly mixed concrete is specified in ASTM C1064. True of
False? - Answers -False

The sample of concrete used for temperature determination must be rodded 25 times.
True or False? - Answers -False

, Sampling by this method is required when tests are to be made to determine _____ with
specification requirements. - Answers -Compliance

This method covers sampling from four types of mixtures which are _____, _____,
_____, and _____. - Answers -Stationary mixers, paving mixers, revolving drum mixers,
and open top mixers

The maximum allowable time between obtaining the first and final portions of a
composite sample is _____ minutes. - Answers -15

Concrete samples from a truck mixer must be obtained before any water or admixtures
are added to the mixer at the job site. True or False? - Answers -False

The composite samples from a truck mixer must be obtained from the _____ portion of
the batch. - Answers -Middle

When the concrete contains aggregate larger than that permitted for a particular test
method, the sample of concrete must be _____ _____ before making the test. -
Answers -Wet sieved

The slump test is applicable to plastic concrete with a maximum size aggregate of
_____. - Answers -1.5 in. [37.5 mm]

When the concrete contains aggregate larger than allowed for the slump test, the large
aggregate must be _____. - Answers -Removed by wet sieving the sample over 1.5 in.
[37.5 mm] sieve

The mold for making the slump test is in the shape of _____. - Answers -The frustum of
a cone

The height of the slump mold is _____. - Answers -12 in. [300 mm]

The interior surface of the slump mold is allowed to have minor irregularities. True or
False? - Answers -False

For use in the slump test, the end or both ends of the tamping rod must be _____. -
Answers -Rounded to a hemispherical tip

The sample of concrete for use in making the slump test must be obained in
accordance with ASTM Standard _____. - Answers -C172, Standard Practice for
Sampling Freshly Mixed Concrete

The slump mold should be in a dry condition before beginning the test. True or False? -
Answers -False

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller GEEKA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81989 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart