Where is the union located for a gas appliance? - Answer-A union fitting shall be provided for appliance connected by rigid metallic pipe. Such unions shall be accessible and located within 6 feet of the appliance. Where is gas piping permitted? - Answer-Gas piping may be installed in public cor...

[Show more]

Preview 2 out of 6  pages

  • September 25, 2024
  • 6
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Gas Master
  • Gas Master
avatar-seller
lectknancy
NYC Gas Code Exam Questions and
Answers
Where is the union located for a gas appliance? - Answer-A union fitting shall be
provided for appliance connected by rigid metallic pipe. Such unions shall be accessible
and located within 6 feet of the appliance.

Where is gas piping permitted? - Answer-Gas piping may be installed in public corridors
in residential buildings that do not have floors below grade or in multi use buildings that
have a residential occupancy in accordance with the following, Gas piping shall be
permitted to be installed within a public corridor at the lowest level of the building or the
lowest residential level of the building. All gas valves located within the public corridor
shall be accessible for maintenance and inspection. Gas pressure within the public
corridor piping shall not exceed 1/2 psi. The completed piping within the public corridor
is to be tested and proven tight at 10 psig for a minimum of 30 minutes. The public
corridor shall be ventilated in accordance with the New York City Mechanical Code. The
pipe shall not be installed in a return air plenum. Pipes must be welded.

How much must piping for other than dry gas conditions be sloped? - Answer-Not less
the 1/4 inch in 15 feet to prevent traps.

Hanger spacing for 3/4 inch and 1 inch gas pipe - Answer-8 feet

When is water permitted for testing? - Answer-Fresh water may be used the test
medium where the required test pressure exceeds 100 p.s.i.g.

When do need temporary restraints when testing? - Answer-Expansion joints shall be
provided with temporary restraints, if required, for the additional trust load under test.

What must each digital gauge used to measure pressure in the magnitude of 3 and
higher read? - Answer-The gauge shall have a minimum reading of 1/100 of a p.s.i.g.

Where pipe passes through an outside wall, this piping shall not be less than how many
inches outside of the buildings? - Answer-With conduit going through the wall, pipe shall
not be less than 4 inches outside the building and sleeve shall be at least 1 inch beyond
the inner side of the wall. Pipe shall be vented above grade to the outdoors and shall be
installed so as to prevent the entrance of water and insects.

Threaded pipe may be used up to 4 inches at pressure no greater than? - Answer-1/2
p.s.i.g.

Gas piping going through the foundation wall of a building, shall be protected by? -
Answer-Encasing it in a protective sleeve.

, Gas piping in solid floor shall be installed in a conduit of schedule 40 pipe. This conduit
shall extend not less than how many inches above the floor? - Answer-2 inches.

All exterior gas piping shall be elevated not less than how many inches above ground
and roof surfaces? - Answer-3 1/2 inches.

The untreated portion of gas piping outlets must extend at least how many inch through
finished ceilings and walls? - Answer-1 inch

Underground piping systems shall be installed a minimum depth of, how many inches
below grade? - Answer-24 inches

The unthreatened portion of gas piping outlets extending through floors or outdoor
patios and slabs must extend at least, how many inches above them? - Answer-2
inches

What gas is prohibited from being used for testing gas piping? - Answer-Oxygen

The testing duration for gas piping with distribution pressures over 1/2 p.s.I.g through 5
p.s.I.g is? - Answer-50 p.s.I.g for a minimum of 30 minutes.

Supports for 1 inch gas piping shall be spaced no more than, how many feet apart? -
Answer-8 feet

The gas shut off valve shall be within how many feet of the appliance? - Answer-6 feet

Located on the supply side of the meter, every meter shall be equipped with a what? -
Answer-Shut off valve

Gas distribution piping with pressures up to 1/2 p.s.I.g, shall be tested at a pressure of
how many P.s.I.g?, and a minimum of how many minutes? - Answer-3 p.s.I.g for 30
minutes

What joints is acceptable in gas piping? - Answer-Threaded, flanged and welded

Gas meters and service piping is found in what part of the F.G.C? - Answer-Appendix E

What is the final step before you restore gas service after a shutdown? - Answer-The
gas utility company shall be notified by owner or his or her authorized representative.

All factory applied coated and wrapped pipe shall be pressure tested at a minimum of
what p.s.I.g? - Answer-90 p.s.ig.

The holder of the plumbing permit shall give how many days prior written notice for
inspection? - Answer-2 days

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller lectknancy. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76799 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart