Continuous vent - Answer-A vertical vent that is a continuation of the drain to which it connects
Storm water drainage piping - Answer-A piping system designed to control and convey excess ground water to a suitable location
Private sewage disposal system - Answer-When no public sewer intende...
Sample Questions Part I Plumbing Code
Exam Questions with Latest Update
Continuous vent - Answer-A vertical vent that is a continuation of the drain to which it
connects
Storm water drainage piping - Answer-A piping system designed to control and convey
excess ground water to a suitable location
Private sewage disposal system - Answer-When no public sewer intended to serve any
lot or premises is available in any thoroughfare or right of way abutting such a lot or
premises, drainage piping from the building shall be connected to
__________________________.
Fixture unit - Answer-A unit which is equivalent to the flow rate of one (1) cubic foot of
water per minute or 7.5 gpm of water
Water tight - Answer-Roof joint shall be
Lavatory - Answer-A fixture designed for the washing of hands or face, sometimes
called wash basin
Excessive water pressure - Answer-A condition in the distribution system where it could
damage or create condition that will damage components of the distribution system or
create a nuisance is termed as ________________
Stack - Answer-The vertical main soil, waste or vent piping
Back pressure - Answer-Air pressure in drainage pipes greater than atmospheric
pressure
Health officer - Answer-No clevical toilet shall be installed in any building unless first
approved by the __________________
Plumbing system - Answer-All water supply, drainage, venting system and all fixtures
and their traps complete with their connection
3/8 inch - Answer-The minimum diameter size of water supply pipe to a lavatory is
_______
36 hours - Answer-Request for inspection by the master plumber to the administrative
authority is required to be made in advance at least before the work to be tested
, Air gap drainage - Answer-The vertical distance that waste travels through open air
between the waste pipe and the indirect waste receptor is _________________
Branch interval - Answer-A means of measurement for vertical waste or soil stack. It is
equal to each floor level or storey in a building but are always at least eight-feet
intervals
Continuous waste - Answer-A drain connecting the compartments of a certain fixture to
its trap is called
Rain water - Answer-Storm water is ___________________
Bushing - Answer-A pipe used to reduce the size of an opening is called
8 psi - Answer-The minimum pressure that should be maintained for fixtures containing
flush tank supplies shall be
Gutter - Answer-A piece of chemical fitted under another piece of flat metal or wood
over which water is expected to run is called
10 ft - Answer-Support anchorage of piping shall not exceed an interval of
Fittings and adaptors - Answer-When connecting plastic pipe to other types of piping,
the specific transition intended shall be made with approved ________________
Rough piping inspection - Answer-The inspection of a gas piping system prior to
covering or concealing such pipe is called
Copper tube brazed - Answer-Copper tubing used for water piping under concrete slabs
within a building shall be
60 psi - Answer-The static water pressure at the water meter is 80 psi. At the outlet 40 ft
above the meter, the static water pressure would be approximately
10 gal/min - Answer-The water demand for shower head per day is
6 inches - Answer-Vent pipes may offset horizontally when the distance above the
extreme overflow level of the fixture is at least
5.00 - Answer-The minimum plumbing permit charge for one unit is
Storm sewer - Answer-A drainage pipe used to carry main of surface water, cooling
water and similar liquid waste is
Vents - Answer-Expansion joints shall be acceptable except in piping for
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller lectknancy. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.49. You're not tied to anything after your purchase.