PROPANE Final Practice Exam With
Correct Questions And Answers 2024
Cylinders .stored .within .a .residential .building, .including .the .basement .or .any .storage .area
.in .a .common .basement .of .a .multiple-family .building .and .attached .or .detached .garages,
.shall .be .limited .to .cylinders .each .with .a .maximum .water .capacity .of ._______ .and .shall
.NOT .exceed .5.4 .lb .aggregate .water .capacity .per .each .living .space .unit. .- .correct
.answer.2.7 .lbs
All .new .Class .I .permit .holders .must .provide .bulk .storage .capacity .of .NOT .less .than .an
.aggregate .of .___________ .water .gallons. .- .correct .answer.18,000
LP-gas .containers .shall .be .located .__________ .unless .specifically .allowed .to .be .inside. .-
.correct .answer.Outside .buildings
Effective .January .1, .1993, .a .________ .shall .be .applied .to .all .portable .refillable .LP-Gas
.cylinders .of .100 .lbs .or .less .NOT .filled .on .site. .- .correct .answer.Warning .Label
A .Type .B .or .Type .L .gas .vent .shall .terminate .at .least ._________ .in .vertical .height .above
.the .highest .connected .appliance .draft .hood .or .flue .collar. .- .correct .answer.5 .feet
All .appliances .using .electrical .controls .shall .have .the .controls .connected .into .a
.________. .- .correct .answer.Permanently .live .circuit
All .LP .gases .shall .be ._______ .prior .to .delivery .with .a .warning .agent .down .to .a
.concentration .in .air .of .NOT .over .1/5 .the .lower .flammability .limit. .- .correct
.answer.Odorized
All .metallic .equipment .and .components .that .are .______ .shall .be .coated .or .protected .and
.maintained .to .minimize .corrosion. .- .correct .answer.Buried .or .mounded
The .upper .flammability .limit .of .propane .vapor .is ._____. .- .correct .answer.9.6
A .sniff .test .is .done .to .______ .when .LP-gas .is .delivered .to .the .bulk .plant. .- .correct
.answer.Detect .odorization
, A .clearly .identified .and .accessible .switch .or .circuit .breaker .shall .be .installed .at .a .location
.NOT .less .than ._______ .or .more .than .100 .feet .from .the .dispensing .device .to .shut .off
.power .in .the .event .of .a .fire, .accident, .or .other .emergency. .- .correct .answer.20 .feet
Where .work .is .being .performed .on .piping .that .contains .gas, .provisions .for .___________
.shall .be .made .before .alterations .are .made .in .a .metallic .piping .system. .- .correct
.answer.Electrical .continuity
Air .for .cooling, .heating, .or .ventilation .distributed .to .habitable .spaces .is .known .as
.__________. .- .correct .answer.Circulating .air
ASME .code .refers .to .the .__________ .of .the .American .Society .of .Mechanical .Engineers.
.- .correct .answer.Boiler .and .pressure .vessel .code
A .chimney .for .residential .type .or .low .heat .appliances .shall .extend .at .least .2 .feet .higher
.than .any .portion .of .a .building .with .a .horizontal .distance .of .__________. .- .correct
.answer.10 .feet
The .location .where .connections .and .disconnections .are .made .or .where .LP-Gas .vented
.to .the .atmosphere .in .the .course .of .transfer .operations .is .known .as .__________. .- .correct
.answer.Point .of .transfer
Appliances .or .equipment .that, .because .of .their .intended .modes .of .use .or .operation, .are
.capable .of .providing .sufficient .thermal .energy .to .ignite .flammable .gas-air .mixtures .are
.known .as ._________. .- .correct .answer.Sources .of .ignition
Where .___________ .are .used, .they .shall .NOT .extend .from .room .to .room .or .pass
.through .walls. .- .correct .answer.Flexible .connectors
Illuminating .appliances, .clothes .dryers, ._________ .and .outdoor .grills .need .not .be
.equipped .with .sediment .traps. .- .correct .answer.Ranges
___________ .must .never .be .used .for .room .heating. .- .correct .answer.Ranges, .hot .plates,
.OR .laundry .stoves
An .approved .manual .shutoff .shall .be .installed .within .________ .of .the .appliance .it .serves.
.- .correct .answer.6 .feet
Generally, .with .aboveground .containers .________ .paint .is .preferred .unless .the .system .is
.installed .in .an .extremely .cold .climate. .- .correct .answer.Light .reflecting
Vents .or .vent .connectors .for .gas-fired .toilet .installations .that .are .capable .of .being
.contacted .during .casual .use .of .the .room .in .which .the .toilet .is .installed .shall .be .________
.to .prevent .such .contact. .- .correct .answer.Protected .or .Shielded