The regulations to enforce compliance of b.) California Code of Regulations; Title 23, Chapter 16
underground storage tank systems in the
state are found in?
a.) Code of Federal Regulations, 40 CFR Part
281
b.) California Code of Regulations, Title 23,
Chapter 16
c.) Code of Federal Regulations, 40 CFR Part
280
d.) California Code of Regulations, Title 23,
Chapter 17
By definition an "underground storage tank b.) The tank, all connected piping, ancillary equipment and containment system
system" includes
(H&SC, Sec 25281(z))
a.) The tank, all connected piping and
dispensers
b.) The tank, all connected piping, ancillary
equipment and containment system
c.) Only the tank
d.) Only tanks totally beneath the surface of
the ground
Under-dispenser containment was required a.) December 31, 2003
for all UST systems by _______ _.
CCR Title 23, Sec 2636(g)(C)
a.) December 31, 2003
b.) July 1, 1987
c.) January 1, 1984
d.) January 1, 2000
1/25
,10/3/24, 4:54 AM
According to California Law, UST systems For ALL tanks before use (H&SC 25290.2 (I))
installed after July 1, 2003, require a one-time d.) In all cases
ELD test to ensure that the tank is product
tight... H&SC, Sec 25290.2(i)
a.) If the tank is located within one (1) mile of
a public drinking water well
b.) If the tank is located within 1000 feet of a
public drinking water well
c.) Unless the tank is equipped with
secondary containment
d.) In all cases
The written report submitted to the local b.) Cause of the release
agency after an unauthorized release is
required to include the following except: CCR Title 23, Sec 2652(c)
a.) Description of actions taken to stop the
release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was
discovered
An unauthorized release which does not D. All of the above
escape from secondary containment only
requires a record on the operator's H&SC, Sec 25294
monitoring reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the
secondary containment
C. It was cleaned up within 8 hours of
detection
D. All of the above
The annual monitoring certification may be D. A person who meets the requirements of both a and b
performed by:
CCR Title 23, Sec 2715(i)
A. A person possessing the appropriate
contractors licenses
B. An individual trained and certified by the
manufacturer of the monitoring equipment
C. A designated UST operator
D. A person who meets the requirements of
both a and b
The following is true of secondary a.) Must be tested every 24 months
containment testing, EXCEPT:
CCR Title 23, Sec 2637(a)
a.) Must be tested every 24 months
b.) Must be tested every 36 months
c.) Results must be submitted to the local
agency within 30 days of testing
d.) Local agency must be notified 48 hours
prior to testing
2/25
, 10/3/24, 4:54 AM
Records of cathodic protection system d.) 6.5 years
maintenance must be kept on file for
______________. CCR Title 23, Sec 2712(b)
a.) 10 years
b.) 1.5 years
c.) 3 years
d.) 6.5 years
Impressed current cathodic protection a.) 60 days
systems shall be inspected no less than
every _______to ensure that they are in CCR Title 23, Sec 2635(a)(2)
proper working order:
a.) 60 days
b.) 90 days
c.) 30 days
d.) 120 days
Monthly monitoring data must be kept on a.) 3 years
file for __________ _.
CCR Title 23, Sec 2712(b)
a.) 3 years
b.) 6.5 years
c.) 5 years
d.) For the life of the UST system
By December 22, 1998, all automatic line leak c.) Shutting down the pumping system
detectors installed on single-walled
pressurized piping must be capable of: CCR Title 23, Sec 2666(c)
a.) Restricting product flow
b.) Triggering an audible and visual alarm
c.) Shutting down the pumping system
d.) Shutting off the flow at the dispenser
When an automatic tank gauge is utilized for c.) Outside air temperature
single-walled tank leak detection, it shall
generate a post-test hard copy data report CCR Title 23, Sec 2643(b)(1)
of the following information, except:
a.) Liquid volume
b.) Fuel depth
c.) Outside air temperature
d.) Time and date of test
If a UST system is utilizing an overfill alarm, c.) 90%
the alarm must be triggered to alert the
transfer operator when the tank is no more CCR Title 23, Sec 2635(b)(2)(A)
than ______ full
a.) 85%
b.) 95%
c.) 90%
d.) 80%