cbet practice test with correct questions
the operating principle of ultrasound transducers
the primary advantage of fluid column ecg electr
if the output of a exclusive or gate is low the t
Institution
CBET Practice
Course
CBET Practice
$13.99
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
CBET Practice Test With Correct Questions
And Answers 2024
The .operating .Principle .of .ultrasound .transducers .is .the .- .correct .answer.Piezoelectric
.effect
The .primary .advantage .of ."Fluid .Column" .ECG .Electrodes .is .the .- .correct
.answer.Reduction .of .artifacts .due .to .patient .movement
If .the .output .of .a .Exclusive-OR .gate .is .low, .the .two .inputs .must .be .- .correct .answer.Either
.high .or .low
The .detection .of .IV .infiltrations .is .accomplished .by .- .correct .answer.Frequent .visual
.inspections .of .the .infusion .site
Apnea .is .- .correct .answer.cessation .of .breathing
A .JFET .is .a .device .that .can .be .thought .of .as .a .- .correct .answer.Voltage .controlled .current
.source
During .a .pulmonary .function .nitrogen .washout .test, .the .patient .breathes .- .correct
.answer.Pure .Oxygen
An .Electronic .device .that .creates .a .sustained .a .sustained .myocardial .depolarization .of
.the .heart, .to .stop .ventricular .or .atrial .fibrillation, .is .known .as .a .(n) .- .correct
.answer.Defibrillator
maintenance .of .essentially .constant .conditions .in .the .body's .internal .environment .is
.called .- .correct .answer.Homeostasis
Examples .of .ionizing .radiation .include .- .correct .answer.Alpha .particles, .gamma .rays, .x-
rays
Changing .a .cardiac .monitor .from .monitor .mode .to .diagnostic .mode .affects .the .- .correct
.answer.Bandwidth
An .abnormal .swelling .of .tissues .is .called .- .correct .answer.Edema
, During .the .normal .use .of .a .piece .of .medical .equipment, .current .flowing .in .the .patient
.between .any .patient .connection .and .all .other .patient .connections, .and .not .intended .to
.produce .a .physiological .effect .is .called .- .correct .answer.Patient .auxiliary .current
A .nurse .reports .that .a .automated .vital .signs .monitor .is .displaying .lower .then .expected
.blood .pressure .values. .A .likely .cause .is .- .correct .answer.Using .a .cuff .that .is .to .large
A .VLAN .(Virtual .Local .Area .Network) .would .be .used .instead .of .subnetting .a .network .-
.correct .answer.Weh .devices .in .different .physical .locations .(not .going .back .to .the .same
.router) .need .to .be .on .the .same .network
The .volume .of .packed .red .blood .cells, .expressed .as .a .percentage .of .total .blood .volume,
.is .called .the .- .correct .answer.Hematocrit
The .Joint .Commission's .hospital .accreditation .standards .require .the .maintenance
.intervals .on .medical .equipment .to .be .- .correct .answer.Based .on .manufactures
.recommendations, .risk .levels, .and .current .hospitals .experience
All .of .the .following .statements .are .incorrect .about .intra-aortic .balloon .pumps, .except .-
.correct .answer.It .improves .perfusion .through .the .coronary .arteries .and .reduces .the
.coronary .work .load
The .normal .range .of .pH .for .arterial .human .blood .is .approximately .- .correct .answer.7.36-
7.44
NFPA .99 .requires .that .all .patient .care-related .electrical .equipment .used .in .patient .care
.rooms .be .be .tested .before .being .put .into .service .for .the .first .time .and .after .any .repair .or
.modification .that .might .have .compromised .electrical .safety. .in .addition, .this .type .of
.equipment .must .be .tested .at .which .of .the .following .intervals .- .correct .answer.According
.to .facility .establish .policies .and .procedures
For .an .electrocardiogram, .lead .II .refers .to .the .voltage .between .- .correct .answer.Left .leg,
.right .arm
The .hospital .buys .a .computerized .ECG .data .acquisition .system, .composed .of .a .main
.server .and .mobile .signal .acquisition .ECG .carts. .The .sales .person .said .the .ECG's .could
.be .done .at .any .bedside, .and .with .the .cardiograph .plugged .into .the .hospital .backbone,
.ECGs .are .directly .archived .onto .the .main .server. .This .works .fine .from .all .ports .in .the
.hospital .except .for .those .on .a .particular .floor. .Very .likely .- .correct .answer.The .ethernet
.crossover .cable .is .still .attached
The .two .types .of .commonly .available .manual .sphygmomanometers .are .- .correct
.answer.Aneroid .gauge .and .mercury .column
When .using .internal .paddles, .an .interlock .limits .the .maximum .output .power .of .a
.defibrillator .to .- .correct .answer.50 .joules