NYC Master Electrical Exam with correct
answers
neutral |point |- |ANSWERS✔✔ |The |common |point |on |a |wye-connection |in |a
|polyphase |system |or |midpoint |on |a |single |phase, |3-wire |system, |or |midpoint |of |a
|single |phase |portion |of |a |3-phase |delta |system, |or |a |midpoint |of |a |3-wire, |direct
|current |system
In |the |NEC |the |words |___________indicate |a |mandatory |requirement |- |ANSWERS✔✔
|Shall |or |shall |not
On |a |four |wire |Delta |connected |system |with |a |midpoint |of |one |phase |winding |is
|grounded, |only |the |conductor |or |bus |bar |having |a |higher |phase |voltage |the |ground
|shall |be |durably |and |permanently |marked |by |an |outer |finish |that |is |_______ |in
|color |or |by |other |effective |means. |Such |Identification |shall |be |placed |at |each |point
|on |the |system |where |connection |is |made |if |the |grounded |conductor |is |also |present.
|- |ANSWERS✔✔ |Orange
The |required |working |space |for |access |to |live |parts |operating |at |300 |V |to |ground,
|where |there |are |exposed |live |parts |on |one |side |and |grounded |parts |on |the |other
|side |is |____________. |- |ANSWERS✔✔ |3 |feet |6 |inches
The |dimensions |of |working |space |for |access |to |live |parts |operating |at |300 |V,
|nominal |to |ground, |where |there |are |expose |live |parts |on |both |sides |of |the
|workspace |is________________. |- |ANSWERS✔✔ |4 |feet
110.26 |A1- |Dead |front |assemblies |working |space |- |ANSWERS✔✔ |30" |for |non-
electrical |parts
36" |for |electrical |parts
The |working |space |in |front |of |the |electrical |equipment |shall |not |be |less |than
|_______wide, |or |of |the |width |of |the |equipment, |whichever |is |greater. |- |ANSWERS✔✔
|30"
,Large |equipment |- |ANSWERS✔✔ |1200 |A |or |greater |and |over |6 |feet |wide
Large |equipment |means |of |egress |- |ANSWERS✔✔ |Two |means |of |egress |24" |wide |by
|6.5 |feet |tall |unless |the |following |condutions |are |met |
1) |unobstructed |egress
2) |Double |the |workspace
Headroom |shall |not |be |less |than |_______. |- |ANSWERS✔✔ |6.5 |feet |or |the |height |of
|the |equipment
Live |parts |of |electrical |equipment |operating |at |______volts |or |more |she'll |be |guarded
|against |accidental |contact |or |approved |enclosures |or |by |any |of |the |following |means
|- |ANSWERS✔✔ |50 |volts |
4) |by |elevation |of |8 |feet |or |more |above |the |floor |or |other |working |surface
A |fence |shall |not |be |less |than |______feet |in |height |- |ANSWERS✔✔ |8 |feet
One |entrance |to |enclosures |for |electrical |installations |as |described |in |110.31 |not
|less |than |_______wide |and |_________high |shall |be |provided |to |give |access |to |the
|working |space |around |the |electrical |equipment |- |ANSWERS✔✔ |30 |inches |and |6.5
|feet
Network |compartments |shall |have |at |least |________means |of |access. |Each |door |she'll
|have |an |access |that |leads |to |a |legal |exit. |- |ANSWERS✔✔ |Two
Where |rear |access |is |required |to |work |on |deenergized |parts |on |the |back |of |enclosed
|equipment |a |minimum |working |space |of |__________horizontally |shall |be |provided |-
|ANSWERS✔✔ |30 |inches
All |non-current |carrying |metal |parts |of |electrical |equipment |and |all |metal |raceways
|and |cable |shall |be |solidly |grounded |and |bonded |to |all |metal |pipes |in |rails |at |the
,|portal |and |the |intervals |not |exceeding |_____________throughout |the |tunnel. |-
|ANSWERS✔✔ |1000 |feet
Manhole |workspace |for |cabling-A |clear |workspace |not |less |than |_______wide |shall |be
|provided |were |cables |are |located |on |both |sides |and |not |less |than |_______were
|cables |are |only |on |one |side. |- |ANSWERS✔✔ |3 |feet |
2-1/2 |feet
Access |to |manhole |dimensions. |Rectangular |access |openings |shall |not |be |less |than
|_______. |Round |access |openings |in |a |manhole |shall |be |not |less |than |______inches |in
|diameter |- |ANSWERS✔✔ |26" |x |22"
26"
Manhole |openings |for |personnel |shall |be |located |where |they |are |not |directly |above
|electrical |equipment |or |conductors |in |the |enclosure. |Where |this |is |not |practiceable
|either |a |________or |a |_______shall |be |provided. |- |ANSWERS✔✔ |Protective |barrier |of
|fixed |ladder
And |insulated |grounded |conductor |of |_____or |smaller |shall |be |identified |by |a
|continuous |white |or |gray |outer |finish |or |by |three |continuous |white |stripes |on |other
|than |green |insulation |along |its |entire |length. |- |ANSWERS✔✔ |6 |awg
Manhole |covers |shall |be |over |______pounds |or |otherwise |designated |to |require |the
|use |of |tools |to |open. |- |ANSWERS✔✔ |100 |pounds
The |grounded |conductors |of |other |systems |shall |have |a |different |outer |covering
|conforming |to |200.6A |or |200.6B |or |by |an |outer |covering |of |______or |_______with |a
|readily |distinguishable |colored |stripe |other |than |green |running |along |the |insulation
|- |ANSWERS✔✔ |White |or |gray
Where |conductors |of |different |systems |are |installed |in |the |same |race |way, |one
|system |she'll |have |a |neutral |having |an |outer |covering |of |white |or |natural |gray |and
|each |other |system |having |a |neutral |shall |have |an |another |covering |of |-
|ANSWERS✔✔ |White |with |colored |Stripe |other |than |green |or |distinguish |by |other
|suitable |approved |means
, For |screw |shell |devices |with |attach |leads |the |conductor |attached |to |the |screw |shell
|shall |have |a |_______or |________finish. |- |ANSWERS✔✔ |White |or |gray
In |addition |to |the |number |of |branch |circuits |required |by |other |parts |of |the |section
|_______or |more |20 |A |small |appliance |branch |circuits |shall |be |provided |for |all
|receptacle |outlets |specified |by |210.52B. |- |ANSWERS✔✔ |Two
An |individual |branch |circuit |shall |be |provided |for |each |_________receptacle |required
|by |210.52 |I. |- |ANSWERS✔✔ |Air-Conditioning
Branch |circuits |required |in |a |dwelling |unit. |- |ANSWERS✔✔ |1) |small |appliance
|branch |circuit
2) |laundry |branch |circuit
3) |bathroom |branch |circuits
4) |Air-Conditioning |(NYC |AMEND)
The |maximum |voltage |drop |on |branch |circuit |conductors |is |_________percent. |-
|ANSWERS✔✔ |3% |
Overall |5%
The |maximum |voltage |drop |on |feeder |circuits |is |________. |- |ANSWERS✔✔ |2%
Overall |5%
Dwelling |unit |circuits |running |through |another |dwelling |unit |in |common |areas.
|What |percentage |of |change |will |require |it |to |be |brought |up |to |current |code? |-
|ANSWERS✔✔ |50%
Receptacle |outlets |in |floors |shall |not |be |counted |as |part |of |the |required |number |of
|receptacle |outlets |unless |located |within |_________of |the |wall. |- |ANSWERS✔✔ |18"