100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Journeyman Electrician Practice Test Exam Questions and Answers 100% Solved $9.99   Add to cart

Exam (elaborations)

Journeyman Electrician Practice Test Exam Questions and Answers 100% Solved

 9 views  0 purchase
  • Course
  • Journeyman Electrician
  • Institution
  • Journeyman Electrician

Journeyman Electrician Practice Test Exam Questions and Answers 100% Solved Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and...

[Show more]

Preview 3 out of 21  pages

  • October 9, 2024
  • 21
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Journeyman Electrician
  • Journeyman Electrician
avatar-seller
JOSHCLAY
©JOSHCLAY 2024/2025 YEAR PUBLISHED, 2024.
Journeyman Electrician Practice Test

Exam Questions and Answers 100%

Solved


Conductors with _____ marked on the insulation are NOT approved for use

in a wet location. - ✔✔THHN



conductors with THHN insulation are approved for use in dry and damp

locations only and conductors with THWN, THHW, and THW insulation are

recognized for use in dry and wet locations.

Given: A one-family dwelling unit with a demand load of 200 amperes is

supplied with a 120/240 volt, single-phase, electrical system from the local

utility company. What is the MINIMUM size aluminum THW conductors

required for use as service-entrance conductors for this residence? -

✔✔4/0 AWG



one-family dwelling 120/240 volt, single-phase, service-entrance

conductors to be sized at an ampacity of not less than 83% of the service

,©JOSHCLAY 2024/2025 YEAR PUBLISHED, 2024.
rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0 AWG THW

aluminum conductors with an allowable ampacity of 180 amperes should

be selected for this dwelling.

Where a 150 kVA, single-phase transformer having a secondary voltage of

120/240 is installed at a multi-family dwelling, the full-load current rating, in

amperes, of the secondary is _____. - ✔✔625 amperes



To find the full-load current rating of the single-phase transformer apply the

single-phase current formula as shown:I = (150 kVA x 1000) / 240 volts =

15,000/240 = 625 amperes

Which one of the following listed circuit breakers is NOT a standard ampere

rating? - ✔✔75 amperes



the standard ampere ratings for fuses and circuit breakers. A circuit breaker

with an ampere rating of 75 amperes is not a standard ampere rating.

The MINIMUM length of free conductor to be left at each junction box for

the purpose of splicing conductors, or making connections to illuminares or

devices shall be _____ . - ✔✔6 inches

, ©JOSHCLAY 2024/2025 YEAR PUBLISHED, 2024.
free conductor is to be left at each junction box for splices or the connection

of luminaires or devices. The intent of this rule is to ensure enough

conductor slack for the terminal connections or splices to be made easily.

In general, overhead service-drop conductors shall NOT be smaller than

_____. - ✔✔8 AWG copper



overhead service-drop conductors to be not smaller than 8 AWG copper or

6 AWG aluminum or copper-clad aluminum. Do not get service-drop

conductors, the overhead conductors between the utility electric supply

system and the service point, confused with the service-entrance

conductors, the conductors from the service point from the utility company

to the service disconnecting means.

When a galvanized eye-bolt is to be used as the point of attachment for an

electrical service, the NEC requires the eye-bolt to be installed NOT less

than _____ above finished grade. - ✔✔10 ft.



provide adequate vertical clearance of the conductors and prevent physical

damage to the conductors and prevent persons from making accidental

contact with the conductors which may create a shock hazard or

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller JOSHCLAY. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77254 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.99
  • (0)
  Add to cart