100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS)/ALREADY GRADED A+ $17.99   Add to cart

Exam (elaborations)

MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS)/ALREADY GRADED A+

 5 views  0 purchase
  • Course
  • MASSACHUSETTS OIL BURNER
  • Institution
  • MASSACHUSETTS OIL BURNER

MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS)/ALREADY GRADED A+

Preview 3 out of 16  pages

  • October 10, 2024
  • 16
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • MASSACHUSETTS OIL BURNER
  • MASSACHUSETTS OIL BURNER
avatar-seller
Americannursingaassociation
MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL
EXAM AND PRACTICE QUESTIONS EXAM
COMPLETE ACCURATE EXAM QUESTIONS WITH
DETAILED VERIFIED ANSWERS (100% CORRECT
ANSWERS)/ALREADY GRADED A+


The cross connection between two supply tanks shall not exceed? - ANSWER660
gallons

When is an automatic draft control not required? - ANSWERWhen the equipment is
designed to control the draft.

Combustion performance testing can indicate: - ANSWERImproper air oil mixture, too
much combustion air, and low pump pressure.

If a second oil-burning appliance is installed in a single chimney, you must insure: -
ANSWERSufficient draft is available for safe operation of all connected equipment.

Delayed ignition can be caused by: - ANSWERWeak ignition transformer

You should replace the oil burner nozzle with: - ANSWERThe manufacturers
recommended nozzle spray pattern and spray angle.

Viscosity problems can be corrected by: - ANSWERDecreasing the nozzle size and
increasing the pump pressure accordingly

The minimum operating pressure of an oil pump is: - ANSWER100 PSI

If a stack relay fails you, must? - ANSWERReplace it with an approved type controller

Aquastats are normally found on what type of heating systems? - ANSWERHydronic

Airstats are found on what type of heating systems? - ANSWERForced warm air
systems

Under sized returns on a warm air system can result in what? - ANSWERShort cycling
of the oil burner

,Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a
steam system? - ANSWERSome radiators not heating quickly enough

Low boiler water temperature in a hydronic hot water system may be caused by? -
ANSWERUndersized oil burner nozzles

Delayed opening oil valves are used to? - ANSWERAllow oil pump to come up to speed

If a steam boiler is to be installed with an automatic feeder it must also have: -
ANSWERA backflow prevention device

How can a damaged heat exchanger be detected on a forced warm air system? -
ANSWERWith a smoke trace candle

If a high limit is installed to prevent high boiler water temperature, what is the function of
the low limit? - ANSWERTo maintain temperature for domestic hot water

On a steam system, a plugged siphon loop can have what affect on the heating
system? - ANSWERInsufficient heat in the living space

On a triple acting aquastat a minimum of 20 degrees is recommend between the high
and low limit, this will prevent? - ANSWERThe boiler going off on high limit before
reaching the minimum circulator temperature

An advantage of flame retention burner is - ANSWERTheir high static pressure enables
boilers and furnaces with tighter more efficient heat exchange passages

The key final adjustment for most oil burners is - ANSWERCombustion air

Dirt or lint buildup in the bevel of the burner fan blades will - ANSWERReduce the
amount of combustion air

To change the air ratio for different firing rates with an adjustable head burner you -
ANSWERAdjust the position of the drawer assembly in the Air tube

All petroleum products are chemical compounds of - ANSWERHydrogen and carbon

1 gallon of #2 oil contains approximately how many BTU's? - ANSWER140,000 BTU's

Flashpoint of a fuel is an indication of - ANSWERThe lowest temperature at which the
fuel will flash but not continue to burn

The pour point of #2 oil - ANSWERCan be lowered by blending with kerosene, can be
lowered with fuel additives, and is the lowest temperature at which it will flow

Maximum fuel allowed without a license - ANSWER10,000 gallons

, Is heating oil gets colder its viscosity (thickness): - ANSWERIncreases

Sulfuric acid in combustion gases can: - ANSWERDamon's the flue lines, it holds in the
flue pipe, and create a scale buildup in the heat exchanger

The home for bacterial growth and sludge in the bottom of the oil tank is -
ANSWERWater

To ensure clean, uncontaminated fuel reaches the oil burner you must - ANSWERInstall
tanks properly, regularly inspect and fix minor defects before they lead to major
problems, and install a quality oil filter

Water in oil tanks come from - ANSWERCondensation, loose or missing fill and vent
caps, and failing to drain water from a tank before installation

When installing an oil tank be sure: - ANSWERThe fill and vent lines are pitched
towards the tank, to install a vent alarm and a tank gauge, and to install an oil filter

Oil lines buried in concrete should be - ANSWERSleeved in plastic or PVC pipe with no
fittings below the floor

Fuel units (oil pumps) preform the following functions - ANSWERMove oil from the tank
to the burner and deliver oil at a constant regulated pressure to the nozzle

The best way to clear a clogged oil line is to - ANSWERUse a hand pump to pull the
blockage out

If the oil level in the tank is 4 feet below the fuel unit in 10 feet away, the approximate
vacuum should be - ANSWER5 - 6 inches

If the operating vacuum reading a significantly above the calculated vacuum, you
probably have a - ANSWERClogged oil filter

If the operating vacuum reading is significantly less than the calculated vacuum, you
probably have a - ANSWERSuction line leak

It is best to connect your unit as a one pipe system instead of a 2 pipe system because
- ANSWEROne pipe leads to longer filter life and eliminates worries about leaking return
lines

A fuel de-aerator: - ANSWEREliminates the need for a return line back to the tank

A cause of pulsating oil pump pressure and a pulsating fire is - ANSWERAir leaks in the
suction line

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Americannursingaassociation. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76800 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart