100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Master Electrician License Correct Questions & Answers (RATED A+) $13.49   Add to cart

Exam (elaborations)

Master Electrician License Correct Questions & Answers (RATED A+)

 5 views  0 purchase
  • Course
  • Master electrician license
  • Institution
  • Master Electrician License

2 wires in nipple - ANSWER31% 20 amp Branch circuit supplies multiple receptacles the receptacles shall have a ampere rating no less than - ANSWER15 amps 24' nipple fill - ANSWER60% 30' nipple - ANSWER53% 42' nipple - ANSWER53% a 120 volt 15-20 amp receptacle shall be located with in...

[Show more]

Preview 3 out of 16  pages

  • October 16, 2024
  • 16
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Master electrician license
  • Master electrician license
avatar-seller
ClassRep2
Master Electrician License Correct Questions &
Answers (RATED A+)

2 wires in nipple - ANSWER31%



20 amp Branch circuit supplies multiple receptacles the receptacles shall have a ampere rating no
less than - ANSWER15 amps



24' nipple fill - ANSWER60%



30' nipple - ANSWER53%



42' nipple - ANSWER53%



a 120 volt 15-20 amp receptacle shall be located with in of air conditioning and refrigeration, heating
systems - ANSWER25 feet



a door used by personnel to exit the work space that is less than 25 feet from the work space shall -
ANSWERswing outward with simple ease



A door used by personnel to exit the workspace that is less than 25 feet from the workspace shall -
ANSWERSwing outward with simple pressure



a fixed infared lamp shall be permitted to be supplied from a - ANSWER50 amp circuit



A HVAC unit is to be connected and needs a ignitor coil. How many circuits does it require -
ANSWER1 circuit



A limited care facility is an area used on a _________ basis for the housing of four or more persons
who are incapable of self preservation because of age, physical limitations due to accident or illness,
or mental limitations, mental illness, or chemical dependency - ANSWER24 hours

,A receptacle connected to a dwelling unit kitchen to serve countertop surfaces shall be supplied by
no fewer than blank small appliance branch circuits - ANSWERTwo



A receptacle connected to one of the small appliance branch circuits can be used to supply a clock -
ANSWERTrue



A separate blank shall supply the elevator shaft way pit lighting and receptacles require a lighting and
or sump pump shall not be connected to the load side of a ground fault circuit interrupt her -
ANSWERBranch circuit



A three phase 4 wire blank power system used to supply power to nonlinear loads may cause the
power system design allows for the possibility of high harmonic current on the neutral conductor -
ANSWERWye connected



a typical wet niche fixture must be installed - ANSWER18'' blow water leval



AC or DC general use snap switches maybe use for control of inductive loads not exceeding blank
percent of the amperage rating of the switch at the applied voltage - ANSWER50 %



access openings in a manhole shall be not less than - ANSWER26"



according to the NEC bare live parts are guarded from the public in the following methods except -
ANSWERprotected by fireproof curtain



According to the NEC bere live parts are guarded from the public in the following methods except -
ANSWERprotected by fireproof curtain



All 15 and 20 amp 120 Installed the bathroom of. Shall have GFCI protection - ANSWERDwelling units
hotels office buildings



All 15 and 20 amp 125 or volt receptacles installed in blank of dwelling units shall have GFCI
protection - ANSWERUnfinished basement



All 15 and 20 amp 125 v receptacles installed in craw spaces at or below grade level in dwelling the
shall have GFCI protection - ANSWERTrue

, All 15 or 20 amp 120 V branch circuit that supply outlet in dwelling units family room dining room
living room parlors libraries Dens bedrooms sunrooms recreation room parlors halls or simular rooms
or areas shall be arc fault protected by arc fault circuit interrupters Loftus the combo type -
ANSWERTrue



All 15 to 20 amp 125 all receptacles of commercial occupancy shall have a GFCI protection in -
ANSWERBathrooms rooftops in kitchen



aluminum ground attached to ground rod - ANSWER18' above earth



An individual 20 amp branch circuit can supply a single dwelling units bathroom outlets and other
equipment within the Bathroom - ANSWERTrue



an insulated grounded conductor of or smaller shall be identified by a continuous white or gray outer
finish, or by three continuous white stripes on other than green insulation along its entire length -
ANSWER6



And equal potential plane in an agricultural building shall be connected to the electrical grounding
system with a copper insulated covered or bare conductor and Not small then - ANSWER# 8



as per New York city code in addition to the number of circuits required in a dwelling unit an
individual branch circuit shall be provided for each receptacle - ANSWERair conditioner



As per NYC NAEC i addition to the number of branch circuits required in a dwelling unit an individual
branch circuit shall be provide for each _____ receptacle - ANSWERAir Conditioner



At least _____ 125 V, single phase, 15 A or 20 A, duplex with ground fault circuit interrupter
receptacle shall be provided in each elevator machine room and elevator machinery space -
ANSWER1



at least one receptacle outlet shall be installed within of the top of a show window for each 12 linear
feet measured horizontally across its length - ANSWER18"



At least one receptacle outlet shall be installed within_____ of the top of a show window each 12
linear feet measured horizontally across its length - ANSWER18

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ClassRep2. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75057 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.49
  • (0)
  Add to cart