Which operating valve is provided in automatic sprinkler systems to limit the flow of water to one direction? (510) - ANS Check valves Which of the following is the most common method for driving a fire pump? (535) - ANS Electric motor Which type of valve is a gate valve that has a yoke on the outside with a threaded stem or screw? (509) - ANS Outside stem and yoke What is the purpose of fire department connections as part of automatic sprinkler systems? (508) - ANS Boost the pressure of the primary water supply As part of the maintenance requirements of NFPA® 25, standpipe and hose fire suppression systems must be flow and hydrostatic tested: (525) - ANS every five years Which pressure-regulating device at a hose outlet uses a spring mechanism that compensates for variations in pressure? (531) - ANS Pressure-reducing devices Water-mist fire suppression systems that utilize air cylinders that have not been discharged should be emptied and tested: (523) - ANS every twelve years Which automatic sprinkler system is continually charged with air that may or may not be under pressure and operates when a sprinkler opens due to a thermally sensitive device and the activation of detection devices? (506) - ANS Preaction sprinkler system The actual hose connections of a standpipe hose valve can be located no more than: (530) - ANS 6 feet (1.8 m) from floor level Which fire protection system is considered a replacement for fixed fire suppression systems that used halogenated hydrocarbon agents? (521) - ANS Water-mist system Which type of standpipe fire suppression system contains water in the system at all times and is attached to a water supply capable of supplying the system demand at all times? (527) - ANS Automatic-wet Which type of sprinkler is a type of spray sprinkler capable of producing characteristic large water droplets and is listed for its capability of providing fire control of specific high-challenge fire hazards? (513) - ANS Control mode specific application Which valve is used to drain water from piping when pressure is relieved in the pipe? (510) - ANS Drain valves

Show more Read less
Institution
Sprinkler
Course
Sprinkler









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Sprinkler
Course
Sprinkler

Document information

Uploaded on
October 17, 2024
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Chapter 12 Test Water-Based Fire
Suppression Systems Questions And
Answers


Which operating valve is provided in automatic sprinkler systems to limit the flow of water to one
direction? (510) - ANS Check valves

Which of the following is the most common method for driving a fire pump? (535) - ANS
Electric motor

Which type of valve is a gate valve that has a yoke on the outside with a threaded stem or
screw? (509) - ANS Outside stem and yoke

What is the purpose of fire department connections as part of automatic sprinkler systems?
(508) - ANS Boost the pressure of the primary water supply

As part of the maintenance requirements of NFPA® 25, standpipe and hose fire suppression
systems must be flow and hydrostatic tested: (525) - ANS every five years

Which pressure-regulating device at a hose outlet uses a spring mechanism that compensates
for variations in pressure? (531) - ANS Pressure-reducing devices

Water-mist fire suppression systems that utilize air cylinders that have not been discharged
should be emptied and tested: (523) - ANS every twelve years

Which automatic sprinkler system is continually charged with air that may or may not be under
pressure and operates when a sprinkler opens due to a thermally sensitive device and the
activation of detection devices? (506) - ANS Preaction sprinkler system

The actual hose connections of a standpipe hose valve can be located no more than: (530) -
ANS 6 feet (1.8 m) from floor level

Which fire protection system is considered a replacement for fixed fire suppression systems that
used halogenated hydrocarbon agents? (521) - ANS Water-mist system

, Which type of standpipe fire suppression system contains water in the system at all times and is
attached to a water supply capable of supplying the system demand at all times? (527) - ANS
Automatic-wet

Which type of sprinkler is a type of spray sprinkler capable of producing characteristic large
water droplets and is listed for its capability of providing fire control of specific high-challenge
fire hazards? (513) - ANS Control mode specific application

Which valve is used to drain water from piping when pressure is relieved in the pipe? (510) -
ANS Drain valves

Which fire protection system requires a proportioner? (524) - ANS Foam-water system

Which type of standpipe fire suppression system contains an empty pipe that is connected to a
permanent water supply? (529) - ANS Semiautomatic-dry

Which classification of standpipe and hose systems is primarily for use by firefighters trained in
handling large handlines (2½-inch [65 mm] hose)? (526) - ANS Class I

Unless otherwise approved, spacing for sprinklers in residential systems is a: (519) - ANS
maximum of 144 square feet (13 m2) per sprinkler

Which fire pump includes advantages such as the ease of installation as a replacement pump,
the compact space required for the pump, and the ease of maintenance of the pump and driver?
(534) - ANS Vertical inline

For which fire pump are the impellers actually located within the water supply source? (534) -
ANS Vertical turbine

What is a primary concern for residential sprinkler systems installed according to NFPA® 13?
(518) - ANS Life safety

All sprinklers discharge water simultaneously in: (506) - ANS deluge sprinkler systems

Which automatic sprinkler system has the advantage of water flowing to the sprinklers from
multiple directions? (507) - ANS Gridded systems

Which type of sprinkler is designed to provide increased life safety in hotels, motels, and similar
residential occupancies? (515) - ANS Quick-response early suppression

Which type of sprinkler is designed to be damage resistant with no removable parts? (515) -
ANS Institutional

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocLaura Galen College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
148
Member since
2 year
Number of followers
38
Documents
6485
Last sold
1 week ago

4.2

44 reviews

5
27
4
4
3
10
2
2
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions