NATE Heat Pump Exam/ Questions with Certified Solutions. Terms like:
The correct way to size a heat pump is to perform both heating and cooling load calculations and select the heat pump size by:
A: Adding the heating load and cooling loads
B: Subtracting the smaller load from the larger...
NATE Heat Pump Exam/ Questions with
Certified Solutions
The correct way to size a heat pump is to perform both heating and cooling load
calculations and select the heat pump size by:
A: Adding the heating load and cooling loads
B: Subtracting the smaller load from the larger load
C: Using the heating load to size the system
D: Using the cooling load to size the system - Answer: D: Using the cooling load to
size the system
Auxiliary electric heat is necessary because:
A: It provides heat for the home during defrosts
B: It provides heat for the home in the event of a heat pump failure
Page 1 of 19
, C: It provides heat for the home if the heat pump is unable to meet the demand
for heat
D: All of the above - Answer: D: All of the above
Reading a voltage across the contacts of the outdoor thermostat means:
A: The thermostat contacts are closed
B: The thermostat contacts are open
C: The thermostat contacts are stuck
D: The thermostat contacts are working correctly - Answer: B: The thermostat
contacts are open
Which of the following is not a type of heat pump?
A: Ground to air
B: Air to air
C: Water to air
D: Direct coupled - Answer: D: Direct coupled
The coefficient of performance is determined by:
A: Dividing the output btuh by the input btuh
B: Dividing the input btuh by the output btuh
Page 2 of 19
, C: Multiplying the input by the output
D: Subtracting the output from the input - Answer: B: Dividing the input btuh by
the output btuh
The coefficient of performance or COP of a heat pump, refrigerator or air
conditioning system is a ratio of useful heating or cooling provided to work
required. Higher COPs equate to higher efficiency.
The "balance point" of a heat pump is:
A: The lowest temperature at which the heat pump can meet the heating
requirement for the structure
B: The lowest temperature at which the heat pump can operate
C: The temperature at which the heat pump has the highest efficiency
D: The point at which the heating and cooling loads meet - Answer: A: The lowest
temperature at which the heat pump can meet the heating requirement for the
structure
Which of the following is an incorrect term for the solenoid valve that switches
the heat pump between the heating and cooling modes?
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Benzo. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $9.19. You're not tied to anything after your purchase.