257 F Correct Ans-When operating at an ambient temperature of 140 F, what is the max
allowable surface temperature of a pump?




True Correct Ans-Potable water systems must be equipped with a drain. T or F?




False Correct Ans-Storage tank inlet may also serve as the tank vent. T or F?




True Correct Ans-Storage tank inlet caps must be retained to prevent loss. T or F?




True Correct Ans-Storage tanks must be equipped with a vent. T or F?




True Correct Ans-Storage tank vent may be used for filling purposes. T or F?




At least 1.5X the pressure exerted by the distance from the tank bottom to the deck fill plate
or vent, but not less than 3 PSI. Correct Ans-What rate of static pressure must a storage
tank withstand?




3 PSI Correct Ans-What is the max pressure that a desalinator can impart to a storage
tank?

,ABYC Systems Certification Exam Review Questions and
Answers 100% Pass
True Correct Ans-Each desalinator must be equipped with an automatic shutoff salinity
detector. T or F?




"For Cold Water Use Only" Correct Ans-What marking must be on pipe or tubes that are
not capable of handling hot water?




125 PSI, 300 PSI Correct Ans-What is the test pressure for water heater tank 15 gal or less?
over 15 gal but under 120 gal?




175 PSI Correct Ans-What is the max pressure relief valve setting for hot water tanks?




210 F Correct Ans-What is the max temperature relief setting for hot water tanks?




125 F Correct Ans-What is the max allowable water output temperature for hot water
system?




True Correct Ans-All potable water system connections shall be positioned above the
normal bilge water accumulation level. T or F?




True Correct Ans-Exposed metallic parts of a potable water system shall have provisions
for electrical bonding. T or F?

, ABYC Systems Certification Exam Review Questions and
Answers 100% Pass
Improper venting Correct Ans-For what reason might a holding tank collapse during pump-
out?




Type I Correct Ans-What type of MSD (Marine Sanitation Device) discharges effluent with
fecal coliform bacteria count <= 1,000 (per 100 ml) and no suspended solids?




Type II Correct Ans-What type of MSD (Marine Sanitation Device) discharges effluent with
fecal coliform bacteria count <= 200 (per 100 ml) and <= 150 mg suspended solids per liter?




Type III Correct Ans-What type of MSD (Marine Sanitation Device) is designed to hold
sewage or any waste derived from sewage?




Retention System Correct Ans-What is the name given to the complete system including
toilets, hoses, pipes, holding tanks and fittings designed to receive, retain, vent and pump out
sewage?




Treatment System Correct Ans-What is the name of the system that includes all sanitation
equipment and fittings designed to receive, treat, vent and discharge sewage?




Siphon break Correct Ans-What is another name for a vented loop that prevents back
siphoning by breaking suction yet allowing normal flow when pressurized?

, ABYC Systems Certification Exam Review Questions and
Answers 100% Pass
5 Correct Ans-When calculating holding tank size, how many flushes per day are included
in the calculation?




0.14 gallons Correct Ans-What volume of human waste is used per flush when calculating
holding tank size?




True Correct Ans-True or False: If a portable toilet is secured and fitted with a deck pump-
out fitting and vent it qualifies as a type III device.




Prevention of siphoning Correct Ans-Why must careful consideration be given to the
location and routing of inlet and discharge lines for manual flush toilets when the "shut-off"
merely bleeds air into the inlet line?



Whenever components are installed below the max heeled water line - to prevent back flow
into the vessel or unintentional siphoning of untreated effluent overboard. Correct Ans-
When and why must siphon breaks be installed in a sewage system?




True Correct Ans-A seacock may be installed instead of a siphon break to prevent
discharge and back siphoning. T or F?




The handle must be lockable in the direction of the holding tank Correct Ans-What special
provision must be included for a sewage y-valve when the discharge seacock is not lockable?

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TheeGrades. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $16.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

85169 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$16.99
  • (0)
  Add to cart