Two master warning switchlights can't silence what? - ✔✔1. Stall EGPWS/TCAS
over speed clacker stab trim clacker
AP disconnect
Config warning Gear warning
How many DC tie contactors are there? - ✔✔5 total. Main, essential, cross, service, ESS TRU 2
What should you do if there is a HOT Start? - ✔✔Affected thrust level back to shut off
Keep the start button going until the ITT is below 120 or for 90 seconds, whichever is first
Advise QRH
Start abort caution message will be displayed
What should you do for a HUNG start? What will FADEC do? - ✔✔The FADEC will abort the start and caution
message will be displayed if N2 is hanging around 6 o'clock
Advise the QRH
What will the FADEC do if the engine has a no light on engine start? - ✔✔After 15 seconds the FADEC will switch
ignition channels
Memory Item: Engine Overspeed or Uncommanded Acceleration - ✔✔Affected Thrust Lever Confirm &
IDLE
Memory Item: Loss of all AC Power (ADG not operative) - ✔✔ADG manual deploy handle. Pull Memory
Item: Aileron System Jammed - ✔✔1. Autopilot. DISENGAGE
Aileron controls (both). Release Pressure
ROLL DISC. PULL, TURN to lock 4. Airplane
Control. TRANSFER
to pilot with operative aileron
, Memory Item: Elevator System Jammed - ✔✔1. Autopilot - DISENGAGE Elevator controls (both) - RELEASE
PRESSURE
PITCH DISC - PULL, TURN and LOCK
Airplane Control - TRANSFER to the pilot with operative elevator
How do you respond to a TCAS RA? - ✔✔Disconnect autopilot
System believes response will happen within 5 seconds and follow the VSI
How do you respond to a EGPWS? - ✔✔Disconnect Autopilot Max thrust and adjust to 15 pitch up
What replaces the analog oil pressure gauge after engine start? - ✔✔N1 fan vibration gauges
Where are the main and APU batteries located? - ✔✔Main - nose cone APU - aft right fuselage
What is the difference between AHRS and IRS? - ✔✔AHRS uses strapped gyros to generate angular rate and
acceleration
IRS is inertial reference system uses ring laser gyros
What is the difference between A/I DUCT FAIL and WING OVRHT? - ✔✔DUCT stands for leak or low pressure in
Canadian
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller TheeGrades. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $11.99. You're not tied to anything after your purchase.