100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
NICET 2 EXAM|100 QUESTIONS AND ANSWERS $12.49   Add to cart

Exam (elaborations)

NICET 2 EXAM|100 QUESTIONS AND ANSWERS

 8 views  0 purchase
  • Course
  • NICET 2
  • Institution
  • NICET 2

NICET 2 EXAM|100 QUESTIONS AND ANSWERS

Preview 2 out of 8  pages

  • October 21, 2024
  • 8
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • NICET 2
  • NICET 2
avatar-seller
Nursephil2023
NICET 2 EXAM|100 QUESTIONS
AND ANSWERS
Where located above floor (within 2.1m or 7ft.) cables shall be securely
fastened at intervals of? - -not more than 18 inches

-Which cable types can be installed in fireproof riser shafts? - -FPLP, FPLR,
and FPL

-How many THHN conductors can fit in a 3/4 size Rigid PVC conduit? - -17

-This is the defined as the height from the continuous floor of a room to the
continuous ceiling of a room or space? - -Ceiling height

-The visible annunciation of the location of operated initiating device shall
not be? - -by the means used to deactivate alarm notification appliances.

-Subsequent trouble signals shall cause trouble notification appliances to
activate as required by what? - -system input/ output matrix

-System equipment shall be maintained in accordance with what? - -
Manufacturer's published instructions

-The detector sensitivity shall not be tested or measured using any device
that administers? - -an unmeasured concentration of smoke or other aerosol
into the detector or smoke alarm

-Sensitivity shall be checked within how long? - -1 year after installation

-Where partitions extend to within 15% of the ceiling height, the spaces
separated by the partitions shall be? - -considered separate rooms

-Spot-type heat detectors shall include? - -Response time index

-The first line of detectors shall be located at or within? - -36 inches of the
peak of the ceiling

-Smoke detectors shall be marked with? - -with their nominal production
sensitivity and tolerance in in percent per foot obscuration

-Spot-type smoke detectors shall be permitted to be located on ceiling or on
the bottom of beams for ceilings with beam depths of? - -less than 10% of
the ceiling height.

, -If any barrier, such as a door, curtain, or retractable partition is located in
sleeping areas, sound pressure level shall be measured? - -with the barrier
placed between the appliance and pillow

-Appliances intended for use in special environments, such as outdoors vs.
indoors shall be what? - -listed for the intended purpose

-In-building emergency mass notification system shall be permitted to be
initiated how? - -by manual or automatic means

-Any signal received by the supervising station that has not restored to
normal condition within 24 hours of initial receipt shall be re-displayed to an
operator as a nonrestored signal and shall be? - -reported to the subscriber

-All operator controls at the proprietary supervising station shall be? - -
operated at each change of shift

-The external antennas of all radio transmitting and receiving equipment
shall be _____________ in order to minimize the possibility of damage by static
discharge or lightning? - -protected

-Where each circuit is served by a dedicated recording device, the number
of reserve recording devices required on site shall be equal to _____ of the
circuits in service and in no case less than one device. - -5%

-The smallest discrete area used for any announcements or signaling? - -
Notification zone

-_______ calculates the actuation time of sprinklers and fusible link-actuated
ceiling vents in compartment fires with draft curtains? - -LAVENT (link
actuated vent)

-__________ Calculates the actuation time of heat detectors and sprinklers? -
-DETACT (detector actuation)

-The choice of the type of radiant energy-sensing detector to use is
determined by what? - -Type of emissions that are expected from the fire
radiator

-_____ ____ refers to the minimum velocity of the smoke necessary to enter
the sensing chamber to cause an alarm without significant delays due to
entry lag? - -Critical Velocity

-Name 3 factors that can affect smoke entry into detection chambers? - -
insect screens, sensing chamber configuration, and location of the detector

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Nursephil2023. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62890 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart