When a device is inaccessible due to excessive height, such as an atrium,
what it the maximum interval for testing? - -18 months

-When installing a wall-mounted fire telephone appliance to the public, what
is the acceptable maximum mounting height from the floor? - -66 inches

-Elevator lobby smoke detectors shall be mounted within a maximum of
which distance from the center-line of the door? - -21 feet

-At minimum, when working near power lines with voltage of 600 volts and
lower, an aerial lift operator shall maintain which distance from the lines? - -
10 feet

-The use of unprotected EMT shall be permitted under which conditions? - -
when in direct contact with the earth

-According to NFPA 70, what is the maximum unsupported length of 1/2-inch
flexible metallic conduit where flexibility is required after installation? - -4
1/2 feet

-What is the maximum bend (in degrees) permitted in a conduit run
between outlet boxes? - -360 Degrees

-If the primary power is disconnected and the fire alarm system goes into an
alarm condition, what is the minimum acceptable time for secondary power
to operate the voice evacuation systems? - -15 minutes

-A riser room temperature switch should activate when the temperature falls
below which level? - -40 degrees F

-According to NFPA 72, what is the maximum sound pressure level
permitted in a space with notification appliances? - -110 dBA

-What is the minimum interval for testing a single-station smoke detector in
multifamily units? - -Annually

-Where should a technician install a detector in relation to beam that is less
than 12 inches deep and less that 8 feet in center? - -At the bottom of the
beam

, -An existing fire alarm cable in a drop ceiling will be spliced. which one of
the following splice locations will comply with NFPA 70? - -secured inside a
listed box or enclosure

-Which function shall be tested for each newly installed smoke detector? - -
smoke entry?

-An 180 foot long corridor is 10 feet wide, with a smooth 10 foot ceiling,
interrupted by 4-inch beams spaced every 10 feet. How many heat detectors
with a listed 30 foot spacing are required? - -6 heat detectors

-At which height must cables be physically protected when being installed
within an exposed ceiling? - -7 feet

-When shall smoke detectors be installed during the construction process? -
-After the final cleanup of all trades

-Where structural members are provided, intermediate metal conduit shall
be secured within which maximum distance from an outlet box" - -3 feet

-The requirement forbidding fire alarm circuits from being T-tapped, unless
indicated by the manufacturer's instructions, is intended to prevent which
type of improper malfunction? - -monitoring integrity of installation
conductors?

-What is the maximum operating temperature of TW insulation? - -140
Degrees F, Table 310.15 (B)(16)

-Which type of meter is used to measure the current draw of a strobe
circuit? - -multimeter

-What is an acceptable document for finding information on spacing of video
imaging smoke detection systems? - -shop drawings in submittal package

-When pulling multiple cable through a junction box, the installer must leave
which minimum length of wire for splicing? - -6 inches of wire

-Which three of the following conditions are symptoms of a heart attack? - -
heartburn, pain in chest, shortness of breath

-Sprinkler water storage containers shall be supervised to indicate what the
water temperature drops to which level? - -40 degrees F

-According to NFPA 72, what is the minimum separation between outgoing
and returning conductors for a Class A loop that is horizontally placed down
to an 8 foot-wide corridor? - -4 feet of separation

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Nursephil2023. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67163 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart