A fire department access road is permitted to be what maximum distance from any portion of the exterior wall of a building - ANSWERS150 Ft
What is the class of an interior wall and ceiling finish that has a flame spread index of 38 and a smoke developed index of 150 - ANSWERSClass b
What is t...
NFPA CFI-1 EXAM Questions & Answers
A fire department access road is permitted to be what maximum distance from any
portion of the exterior wall of a building - ANSWERS150 Ft
What is the class of an interior wall and ceiling finish that has a flame spread index of 38
and a smoke developed index of 150 - ANSWERSClass b
What is the minimum frequency that employees of airport traffic control towers be
instructed on an emergency action plan - ANSWERSAnnual
How often do pipes and fittings for a dry system need to be inspected -
ANSWERSAnnual
A vocational tech school has a woodworking shop used for educational purposes. What
is the occupant load factor for this type of use - ANSWERS50 net ft
What minimum total combined hose stream allowance is required for a hydraulically
calculated sprinkler system protecting an extra hazard area - ANSWERS500 gpm
Foam agents are most common to what class of fires? - ANSWERSClass A and B
When operated at maximum speed fully open indicating valves must remain open for
what minimum amount of time before closing - ANSWERS5 seconds
How much advance notice is required when inspector is investigating a complaint
concerning serious fire and life safety violations - ANSWERSNo advance notice is
required
What is the maximum occupant load allowed for an existing sprinkler two story
assembly occupancy of type ll [000] construction - ANSWERS300
When dots an inspector have the authority to order occupants to vacate a building -
ANSWERSIf an immediate danger exist
Which of the following is a verbal affirmation or declaration made under oath in a court
of law - ANSWERSTestimony
Which stage of a fire within a compartment does the fuel source produce some heat but
has not yet spread to other substances nearby - ANSWERSIncipient
An automatic sprinkler system is required in an airport terminals concourse when it
exceeds what total floor area - ANSWERS12,000 ft
, Which of the following is describe as the propagation of a flame over a surface -
ANSWERSFlame spread
Which flammable and combustible liquids must be stored in a closed tanks or
containers when not in use and ambient or process temperatures are at or above their
flash points - ANSWERSClass II and III
Manual fire alarm box shall be located within how many inches of exit doorways -
ANSWERS60 inches
How often do monitor nozzles used with private service mains need to be inspector -
ANSWERSSemiannual
What is the maximum amount of lumber permitted to be stored in a lumber yard before
a permit is required - ANSWERS100,000 board ft
What is the classification of a flammable liquid with a flash point between 73 degrees F
and 100 degrees F - ANSWERSClass IC
What is the maximum egress capacity allowed for security turnstiles with a clear
passage of less than 32inch - ANSWERS50 people
What is the maximum time permitted for water to be delivered from a dry pipe system
protecting an extra hazard area - ANSWERS45 seconds
Inspection reports for door, shutter, and window assemblies must be retained for what
minimum length of time - ANSWERS3 years
A permit is required when outside storage of flammable cryogens exceed what volume -
ANSWERS60 gallons
What is the maximum distance that manual fire alarm boxes may be located from each
doorway on each floor of a multi-story building - ANSWERS5 feet
Which of the following is a system with automatic sprinklers containing air or nitrogen
under pressure which, when released open a valve and allow water to flow out of the
open sprinklers - ANSWERSDry pipe system
What is the maximum permitted distance between a fire hydrant and a fire department
access road - ANSWERS12 ft
How must individual containers, cartons, or packages of hazardous materials be
marked or label - ANSWERSPer national recognized standards
What temperature rating is required of sprinklers protecting plastic skylights -
ANSWERSIntermediate
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Bestgrades2. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $11.49. You're not tied to anything after your purchase.