Permit Technician/ 106 Questions & Verified Solutions/ Already Graded A+ Terms like:
A building used for assembly purposes with an occupant load of less than 50 persons shall be considered a Group _____ occupancy. - Answer: B
Which of the following rooms would not be permitted to have a ceil...
ICC Bolting/ 146 Questions with Definitive Solutions/
2024-2025.
The special inspector shall furnish inspection reports to the "blank" and to the "blank"? -
Answer: Building Official and Registered Design professional
The special inspector shall provide continuos inspection of: - Answer: Single-pass fillet welds
greater than 5/16 inch in size - 2099 IBC, Table 1704.3, Item 5.3
The special inspections required by this code are not required where the work is done on the
premise of a? - Answer: Approved fabricator - 2009 IBC, Section 1704.2.2
The special inspection of the steel fabrication process shall not be required where the fabricator
does not perform any? - Answer: heating operations - 2009 IBC, Section 1704.3, Exceptions # 1
Page 1 of 20
,According to the Specifications for Structural Steel Buildings, ASTM Standard "blank" is to be
used for the material test for steel sheets. - Answer: A568 - Section A31, Specifications for
Structural Steel Buildings
According to the Specifications for Structural Steel Buildings, the "blank" conducts the material
tests for identification of the structural steel. - Answer: Fabricator or Testing Laboratory -
Section A31, Specifications for Structural Steel Buildings.
According to the Specifications for Structural Steel Buildings, which of the following steel
members are allowed to be unidentified steel? - Answer: Unimportant members, where their
physical properties and weldability would not affect the structure strength - Section A31b,
Specifications for Structural Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, how is steel of
special material to be identified? - Answer: It is marked by the supplier - Section 5.1.1, Code of
Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, how are fabricators
stock steel material identified? - Answer: Certified mill test reports - Section 5.2.2 - Code of
Standard Practice for Steel Buildings and Bridges
According to the Specification for Structural Steel Buildings, what ASTM Standard would apply
to a sample for structural steel pipe? - Answer: A53 - Section A31a - Specification for Structural
Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, the number of
samples required to be tested for structural steel is: - Answer: The number specified by the
ASTM specification - Section 5.1.1 - Code of Standard Practice for Steel Buildings and Bridges
Page 2 of 20
, According to the Specification for Structural Steel Buildings, which ASTM standard would apply
to a sample for structural steel plates? - Answer: A36, A283, and A242 - Section A31a -
Specification for Structural Steel Buildings
According to the Specification for Structural Steel Buildings, "blank" tests are required for
samples for built-up sections consisting of plates over 2 inches in thickness. - Answer: Charpy V-
notch testing - Section A31d, Specification for Structural Steel Buildings
According to the Specification for Structural Steel Buildings, ASTM standard "blank" would apply
to a sample for structural steel bars. - Answer: A36, A529, and A572 - Specification for Structural
Steel Buildings
Steel furnished for structural load-carrying purposes shall be properly : - Answer: Identified -
2009 IBC, Section 2203.1
Steel that is not readily identifiable as to grade by marking and test records shall be: - Answer:
tested - 2009 IBC, Section 2203.1
Where materials or assemblies are required by this code to be labeled, such material and
assemblies shall be labeled by: - Answer: An approved agency - 2009 IBC, Section 1703.5
Inspection of the steel frame for compliance with the approved construction documents should
verify: - Answer: Member location, Bracing, and Stiffening - 2009 IBC, Section 1704.3.2.
Continuous inspection of bolt pre-tensioning is required when using: - Answer: The calibrated
wrench method - 2009 IBC, Section 1704.3.3.3.
Where required by the code, the building owner shall employ a registered design professional
to perform: - Answer: Structural Observation - 2009 IBC, Section 1709.1
Page 3 of 20
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Benzo. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $8.99. You're not tied to anything after your purchase.