Class 1 commodity is more combustible then class 3 correct answers False All holes for lag screws shall be pre-drilled __________ inch less in diameter than the max. root diameter of the lag screw thread. correct answers 1/8in Coach screws shall not be used for support of pipes larger than ________ inch in diameter. correct answers 4 Distance between supports on a riser shall not exceed _________ feet. correct answers 25ft Fire department connections shall be installed so that they are located not less than ______ nor more than ______ above the level of the adjoining ground, sidewalk, or grade surface. correct answers 18in , 48in Flexible couplings shall be installed on risers within_____ inches above and _____ inches below the floor in multi-story buildings. correct answers 12in and 24in For ESFR sprinklers, the clearance between the deflector and the top of storage shall be ____ inches or greater correct answers 36in For extra hazard occupancies, the maximum distance between sprinklers shall not exceed ______ feet correct answers 12ft Hangers shall be designed to support _______ times the weight of water-filled pipe plus ________ at each point of piping support. correct answers 5 and 250 Hose connections and hose stations shall be unobstructed and shall be located not less than ______ nor more than ______ above the floor. Answers correct answers 36in, 60in How high can storage be before it is considered high-piled storage? correct answers 12ft How shall the sprinkler head protecting the dry pipe valve enclosure be fed? correct answers From the dry side of the system In residential applications, fire department connections are required to be a minimum of _______ in size. correct answers 1 1/2" Is the use of reconditioned valves and devices as replacement equipment in existing systems allowed? correct answers Yes Joints for the connection of copper pipe an fittings on dry and preaction systems shall be brazed. correct answers True

Show more Read less
Institution
Sprinkler Tes
Course
Sprinkler tes

Content preview

Sprinkler test || with 100% Errorless Answers.
Class 1 commodity is more combustible then class 3 correct answers False

All holes for lag screws shall be pre-drilled __________ inch less in diameter than the max. root
diameter of the lag screw thread. correct answers 1/8in

Coach screws shall not be used for support of pipes larger than ________ inch in diameter.
correct answers 4

Distance between supports on a riser shall not exceed _________ feet. correct answers 25ft

Fire department connections shall be installed so that they are located not less than ______ nor
more than ______ above the level of the adjoining ground, sidewalk, or grade surface. correct
answers 18in , 48in

Flexible couplings shall be installed on risers within_____ inches above and _____ inches below
the floor in multi-story buildings. correct answers 12in and 24in

For ESFR sprinklers, the clearance between the deflector and the top of storage shall be ____
inches or greater correct answers 36in

For extra hazard occupancies, the maximum distance between sprinklers shall not exceed ______
feet correct answers 12ft

Hangers shall be designed to support _______ times the weight of water-filled pipe plus
________ at each point of piping support. correct answers 5 and 250

Hose connections and hose stations shall be unobstructed and shall be located not less than
______ nor more than ______ above the floor.
Answers correct answers 36in, 60in

How high can storage be before it is considered high-piled storage? correct answers 12ft

How shall the sprinkler head protecting the dry pipe valve enclosure be fed? correct answers
From the dry side of the system

In residential applications, fire department connections are required to be a minimum of _______
in size. correct answers 1 1/2"

Is the use of reconditioned valves and devices as replacement equipment in existing systems
allowed? correct answers Yes

Joints for the connection of copper pipe an fittings on dry and preaction systems shall be brazed.
correct answers True

, Lateral sway bracing shall be spaced at a minimum of __________ feet on center on all feed and
cross mains regardless of size and on all piping 2 1/2" and larger correct answers 40ft

Lateral sway bracing shall not apply to pipes individually supported by rods less than ______
inches long measured between the top of the pipe and the point of attachment to the building
structure. correct answers 6in

Longitudinal sway bracing spaced at a maximum of ________ feet on center shall be provided
for feed and cross mains. correct answers 80ft

No clearance is required if flexible couplings are located within _____ each side of a wall, floor,
platform, or foundation. correct answers 12in

Ordinary hazard occupancy protection areas shall not exceed ________ square feet. correct
answers 130

Pressure tanks should be kept ________ full of water. correct answers 2/3

Pressure tanks should maintain an air pressure of at least ______ psi. correct answers 75PSI

Risers shall be supported by pipe clamps or by hangers located on the horizontal connections
within ________ inches of the centerline of the riser. correct answers 24in

Screwed unions shall not be used on pipe larger than _________ inch correct answers 2in

Sprinklers installed where maximum ambient ceiling temperatures do not exceed 100 degrees
farenheit shall be __________ temperature rated sprinklers. correct answers Ordinary

Sprinklers under glass or plastic skylights exposed to direct rays of the sun shall be of
____________ temperature classification. correct answers intermediate

Starter lengths less than ____ feet shall not require a hanger correct answers 6ft

The distance between the last lateral sway brace and the end of the pipe shall not exceed
_______ feet correct answers 6

The hydraulic symbol for a 45 degree elbow is _______? correct answers EE

The maximum area of coverage by a single sprinkler head in a light hazard occupancy is
__________ square feet. correct answers 225sqft

The maximum area to be protected by any single residential sprinkler shall not exceed ________
square feet. correct answers 144sqft

The minimum distance between sprinkler heads in a compartment is _____ feet. correct answers
8ft

Written for

Institution
Sprinkler tes
Course
Sprinkler tes

Document information

Uploaded on
November 1, 2024
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton NURSING, ECONOMICS, MATHEMATICS, BIOLOGY, AND HISTORY MATERIALS BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS, AND STUDY GUIDE MATERIALS WITH GUARANTEED A+ I am a dedicated medical practitioner with diverse knowledge in matters
View profile
Follow You need to be logged in order to follow users or courses
Sold
747
Member since
3 year
Number of followers
437
Documents
36359
Last sold
1 day ago
Reign Supreme Scholarly || Enlightened.

Get your revised study materials available here and elevate your educational outcomes. I have numerous verified learning materials (Research, Exams Questions and answers, Assignments, notes etc) for different courses guaranteed to boost your academic results. I am dedicated to offering you the best and unique learning content. You are encouraged to inquire further assistance from this end whenever need be. Kindly remember to leave your review, understanding your satisfaction is essential . We highly appreciate clients who always come back for more of the study content we offer, you are extremely valued. All the best.

Read more Read less
3.7

113 reviews

5
48
4
20
3
22
2
8
1
15

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions