100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
S12 SPRINKLER TEST, S13 STANDPIPE TEST, SPRINKLERS SEGMENT 5, S-12 CITYWIDE SPRINKLER SYSTEMS $14.49   Add to cart

Exam (elaborations)

S12 SPRINKLER TEST, S13 STANDPIPE TEST, SPRINKLERS SEGMENT 5, S-12 CITYWIDE SPRINKLER SYSTEMS

 2 views  0 purchase
  • Course
  • S12 Certificate Of Fitness Sprinkler
  • Institution
  • S12 Certificate Of Fitness Sprinkler

S12 SPRINKLER TEST, S13 STANDPIPE TEST, SPRINKLERS SEGMENT 5, S-12 CITYWIDE SPRINKLER SYSTEMS

Preview 3 out of 17  pages

  • November 5, 2024
  • 17
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • S12 Certificate Of Fitness Sprinkler
  • S12 Certificate Of Fitness Sprinkler
avatar-seller
Studyclock
K
C
LO
S12 SPRINKLER TEST,
S13 STANDPIPE TEST,
YC
SPRINKLERS SEGMENT
D

5, S-12 CITYWIDE
U



SPRINKLER SYSTEMS
ST

,THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE
QUALIFICATIONS. - ANS OWNER

RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A
MIN. OF __________ YEARS. - ANS 3

THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH
REQUIREMENTS. - ANS IMPAIRMENT COORDINATOR




K
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S)
ARE CONSIDERED PLANNED REMOVAL FROM SERVICE. - ANS 1




C
SHUTDOWNS AFFECTING MORE THAN _________ FLOOR(S) ARE CONSIDERED
UNPLANNED OUT OF SERVICE CONDITIONS. - ANS 1




LO
NOTIFICATION TO FDNY IS NOT REQUIRED, PROVIDED SYSTEM IS RETURNED TO
SERVICE WITHIN ______ HOURS. - ANS 8

FOR UNPLANNED REMOVAL FROM SERVICE, THE COF HOLDER SHALL IMMEDIATELY
REPORT CONDITION TO THE ___________ AND THE FIRE DEPT. - ANS OWNER OF THE
YC
BUILDING

IF A MINOR DEFECT IS OBSERVED, IT SHALL BE CORRECTED WITHIN _________ DAYS
OR IT WILL BE CONSIDERED AN IMPAIRMENT. - ANS 30

WHAT DOES "OOS" STAND FOR? - ANS OUT OF SERVICE
D

OOS SYSTEMS SHALL BE IDENTIFIED BY PLACING ________ AT FIRE DEPT.
CONNECTIONS, SYS. CONTROL VALVES, AND FIRE COMMAND CENTER - ANS TAGS
U


A _______ SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL VALVE AND ANY
SECTIONAL VALVES. - ANS MASTER FIRE SUPPRESSION PIPING CONTRACTOR
ST




__________ SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC AND FLOW
PRESSURES BEFORE AND AFTER. - ANS DRAIN TEST RESULTS

GREEN TAGS INDICATE THAT __________. - ANS NO IMPAIRMENT WAS FOUND

GREEN TAGS WILL BE PLACED ON THE ____________. - ANS MAIN CONTROL VALVE

SYSTEMS PARTIALLY OR FULLY OUT OF SERVICE SHALL HAVE A ____________ TAG
PLACED ON THE MAIN CONTROL VALVE. - ANS RED

, A _________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE
THE SYSTEM IS FULLY OUT OF SERVICE. - ANS WHITE

A ________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE
THE SYSTEM IS PARTIALLY OUT OF SERVICE. - ANS BLUE

THE IMPAIRMENT COORDINATOR WILL NOTIFY THE ___________ CARRIER, CENTRAL
STATION AND OCCUPANTS. - ANS INSURANCE

PRIOR TO RETURNING A SYS. TO SERVICE, THE ___________ SHALL ENSURE THAT




K
NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. - ANS IMPAIRMENT
COORDINATOR




C
GLYCERIN NOT GREATER THAN _________ PERCENT OR GLYCOL NOT GREATHER
THAN ________ PERCENT SHALL BE USED TO PROTECT FROM FREEZING. - ANS 50,
40




LO
THE COF NUMBER AND SIGNATURE OF COF HOLDER SHALL BE POSTED NEAR THE
____________. - ANS MAIN CONTROL VALVE

__________ SHALL BE READILY AVAILABLE TO ANY REPRESENTATIVE OF THE FIRE
YC
DEPT. THESE ARE TO BE MAINTAINED ON SITE FOR 3 YEARS. - ANS RECORDS

FAILURE TO MAKE INSPECTIONS MAY RESULT IN __________ OF THE COF AND COURT
PROCEEDINGS. - ANS REVOCATION

THE COF HOLDER MAY INSPECT, TEST, AND PERFORM ROUTINE MX IF THEY HOLD
D

THE FOLLOWING CERTS: - ANS REFRIGERATION OPERATING ENGINEER, HIGH
PRESSURE OPERATING ENGINEER, AND NYS HIGH PRESSURE OPERATING ENGINEER.
U


A ________ CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE STANDPIPE AND
SPRINKLER SYSTEMS. - ANS MASTER FIRE SUPPRESSION PIPING CONTRACTOR
(MFSPC)
ST




A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL OCCUPANCIES WITH
_________ SPRINKLER HEADS OR LESS. - ANS 30

ABOUT ______ PERCENT OF FIRES ARE EXTINGUISHED OR CONTROLLED WHEN
SPRINKLERS ARE INSTALLED. - ANS 96

WET PIPE SYSTEMS HAVE WATER AT A MINIMUM TEMP. OF _______ TO PREVENT THE
SYSTEM FROM FREEZING. - ANS 40 FAHRENHEIT

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Studyclock. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81113 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.49
  • (0)
  Add to cart