100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
SCYM (ASCP) QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES 2025/2026 VERIFIED ANSWERS) |ALREADY GRADED A+ $12.99   Add to cart

Exam (elaborations)

SCYM (ASCP) QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES 2025/2026 VERIFIED ANSWERS) |ALREADY GRADED A+

 0 view  0 purchase
  • Course
  • ASCP CERTIFICATION
  • Institution
  • ASCP CERTIFICATION

SCYM (ASCP) QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES 2025/2026 VERIFIED ANSWERS) |ALREADY GRADED A+

Preview 3 out of 17  pages

  • November 14, 2024
  • 17
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ascp certification
  • ASCP CERTIFICATION
  • ASCP CERTIFICATION
avatar-seller
Ashley96
SCYM (ASCP)

Aerosol Containment - ANS-Infectious or doubtlessly infectious materials need to not be sorted
until appropriate
containment measures are carried out. A droplet containment module need to be hooked up to
lessen the risk of publicity to generated droplets and aerosols.
-Only personnel trained in protection protocols ought to be authorized to run these waft
cytometry analyzers and cellular sorters.
-The efficiency of aerosol control measures on the instruments desires to be examined
periodically.
-Sorters need to be engineered with an aerosol evacuation device and this must be on and
operational for the duration of the kind.
-Operators ought to have processes in location to preserve and test the aerosol evacuation
system.
-Records have to be maintained to expose the aerosol evacuation device is functioning
generally.
-The efficiency of aerosol manipulate measures on the units desires to be tested periodically.
The UCD Biosafety Office recommends testing be conducted at the least month-to-month and
documented in writing.
-Observation of the go with the flow scattering using calibrated fluorescent microspheres
including "Glo Germ"™ is a fast and less expensive method to offer good qualitative aerosol
containment facts.
Amplifier - ANS-The electrons, that were transformed from photons, go out the detector the
electric modern travels to the amplifier (amp) wherein it is amplified and converted to a voltage
pulse. This pulse is then converted to a virtual number through the analog-to-digital converter
(ADC). The digital quantity is transferred to the pc and becomes the records that you will
analyze.
Anatomy of the voltage pulse - ANS-The voltage pulse has 3 attributes: The pulse height is the
most top of light amassed. The full pulse width is the time from the begin of the pulse to the stop
of the pulse. The pulse vicinity is the indispensable of the peak over width (time). Each of those
3 measurements presents one of a kind information about the cellular and is used to answer a
particular experimental query.
Anti-kappa - ANS-BCells
anti-lambda marker - ANS-B Cells
anti=kappa marker - ANS-BCells
arc lamp laser - ANS-Arc lamps need optical filters to pick out the best wavelength. They do
now not provide the sensitivity needed to have a look at weak fluorescence but provide a
inexpensive alternative for observing strong fluorescences, as an example, in DNA evaluation.
Argon laser - ANS-Air-cooled argon-ion laser generating blue light at 488 nm. This wavelength
is convenient for the excitation of fluorescein, the first immunofluorescent label for use. Other
air-cooled lasers in popular use consist of He-Ne (633 nm) and He-CD (325 nm).

,Backgating to confirm gating strategies - ANS-Backgating is a beneficial approach of
identification of cells to verify a staining sample or gating method. It allows you to research cells
recognized in a gate on dot plots with different parameters. This can be useful if you are
uncertain of your gates, the expression degrees, non-particular binding or the presence of
useless cells and need extra information to identify your cells.
Band Pass Optical Filter - ANS-A clear out that lets in light between a hard and fast wavelength
to skip via and displays light above and underneath the set wavelength. For instance, a
bandpass filter out with a wavelength of 550/40nm might permit mild between 530nm and
570nm to bypass via, but mirror mild under 530nm and above 570nm.
BioSafety Requirements - ANS-For the functions of running with any human materials and
certain animal materials (to encompass tissues, number one and immortalized mobile traces)
those substances are described as Risk Group 2 (RG2)
materials for laboratory manipulations, which need to be performed with Biosafety Level 2
containment and practices.
BSL 2 containment also consists of the work practices (properly microbiological laboratory
approach) and whilst suitable, a certified, well operating biosafety cabinet (BSC), commonly
Class II, Type A, or Type A/B3. Work can be done in a biosafety cupboard (BSC) as appropriate.
BONE MARROW ASPIRATE - ANS-Add 1 - 2 mL of first pull bone marrow aspirate to a green
top (sodium heparin) tube. Send intact specimen saved at room
temperature within 12 hours of collection. Include four unstained aspirate smears, an unstained
peripheral blood smear and a
copy of the affected person's most current complete blood count number (CBC) and white cell
differential.
BONE MARROW BIOPSY OR FINE NEEDLE ASPIRATE (FNA) - ANS-Submerge in RPMI
tissue subculture medium for most excellent mobile viability (sterile saline is suitable). Send at
room temperature
within 12 hours of series.
Bone marrow maturation - ANS-During the early maturation method, the immature B cells which
are tolerant of the self-antigens gift inside the bone marrow progressively release their hold on
the stromal cells of the marrow. Morphologic changes for the duration of neutrophil maturation
can be diagnosed with the aid of glide cytometry using simultaneous quantitative evaluation of
multiple antigens in concordance with the light scattering properties of the human bone marrow
cells.
Calcium Flux - ANS-The principle of float cytometric Ca2+ flux size is primarily based on
adjustments in fluorescence intensity or emission wavelength of a fluorophore following
chelating of calcium ions
Carryover - ANS-It is critical to evaluate tool carryover from one sample tube to the alternative
whilst evaluating excessive‐sensitivity assays reporting uncommon events. Carryover can be
assessed at some point of the preliminary validation by putting a tube with buffer among pattern
tubes. Data from the blank tubes could be evaluated in the equal gating template as the
samples.
CCD Camera - ANS-The filters direct special spectral bands to laterally wonderful channels on
the fee-coupled device (CCD) detector. The cell photos are collected the use of patented

, time-postpone integration (TDI) generation, which yields fluorescence sensitivity corresponding
to the high-quality go with the flow cytometers
CD10 Marker - ANS-immature Tcells, BCells and PMNs (polymorphonucler)
CD13 Marker - ANS-Monocytes, Polymophonclear, (PMNs)
CD14 Marker - ANS-Moncytes, Polymophonclear (PMNs) dimly expressed
CD16 Marker - ANS-Natural Killer Cells (NK), Polymophonclear, (PMNs), monocytes
CD19 Marker - ANS-B Cells
CD2 Marker - ANS-TCells and NK Cells
CD20 Marker - ANS-B Cells
CD25 - ANS-activated TCells
CD3 Marker - ANS-T cells (Mature T Cells)
CD33 Marker - ANS-monocytes
CD34 Marker - ANS-Stem Progenitor Cells and presently the gold standard for assessment of
HSC, ( hematopoietic stem cell) merchandise for transplant. Used as a marker to perceive and
enumerate stem cells in bone marrow and peripheral blood products for transplant. As cells
mature expression of CD34 is misplaced.
CD34+ Absolute Counts - ANS-Direct dimension of CD34+ blood stem cell absolute counts with
the aid of go with the flow cytometry. ... Whole blood become stained with a
phycoerythrin-conjugated anti-CD34 monoclonal antibody, and, after the lysis of crimson blood
cells, CD34+ cells had been counted in a fraction of the lymphocyte and monocyte gate.
CD4 Marker - ANS-T helper (Th), dimly expressed monocles, used for immunophenotyping
such as HIV (CD4 Counts)
CD45 Marker - ANS-leukocytes, leukemic cells are dim
CD5 Marker - ANS-T Cells and BCell Subset Marker
CD56 Marker - ANS-NK Cells, monocytes dimly expressed
CD8 Maker - ANS-Cytotoxic TCells and Marcorphages
cellular adhesion molecules (CAMs) - ANS-Proteins on plasma membrane of cells that bin
similar proteins on other cells, thereby meiating cell-cellular adhesion. There are four
instructions:
1. Cadherins
2. Ig CAMS
3. Integrins
4. Selectins
Cell Cycle - ANS-Cell Cycle Analysis. Cell cycle evaluation is a very commonplace float
cytometry application. By the usage of a DNA-particular stain, you'll determine a DNA profile
e.G. Discover percentage of the population in G0/G1, S, and G2/M. This data can be used to,
as an instance, screen the effect of an anticancer remedy.
Characterization of syringe-pump-pushed caused pressure - ANS-In syringe-pump-driven
microfluidic structures, strain fluctuations are located in an elastic microchannel. The syringe
pump is pushed with the aid of an electrical stepper motor, from which mechanical oscillations
are expected to generate glide-fee fluctuations and in turn leads to the stress fluctuations within
the channel glide.
Reimbursement on panel layout - ANS-accurate spillover

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Ashley96. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

78252 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.99
  • (0)
  Add to cart