MASTER ELECTRICIAN EXAM QUESTIONS &
ANSWERS
Based on the information shown of this exhibit, the current in the branch circuit for the
HP-5 indoor unit is _________amperes
A.0
B. 7.2
C. 52.0
D. 72.1 - Answers- D. 72.1
The ground fault circuit protection for personnel works on the principle of measuring
unbalanced current between
A. UNDERGROUND CONDUCTORS
B. THE SERVICE DISCONNECT AND BRANCH CIRCUIT
C. THE GROUNDED AND UNGROUNDED CONDUCTORS
D. THE GROUNDING AND UNGROUNDED CONDUCTORS - Answers- D. THE
GROUNDING AND UNGROUNDED CONDUCTORS
A device of group of devices that serve to govern in some predetermined manner the
electric power delivered to the apparatus to which it is connected is a
A. DEVICE
B. CONTROLLER
C. DISCONNECT
D. CIRCUIT BREAKER - Answers- B. CONTROLLER
What is the maximum balanced electrical load permitted, in volt-amperes, for the new
service?
A. 57, 600
B. 99, 840
C. 172, 927
C. 178, 692 - Answers- A. 57, 600
Given: A 3-phase system has a line current of 150 amperes and a line voltage of 208
volts. Determine the total volt-ampere load for the above.
A. 18, 000
B. 31, 200
C.54, 040
D. 93, 600 - Answers- C.54, 040
Given: Acircuit supplying a resistive load has a total current reading of 27 amperes. The
resistance of a faulty connection is 0.21 ohms. The power by the faulty connection is
____ watts.
A. 0.2
B. 5.7
C. 54
,D. 153 - Answers- B. 5.7
In a step-down voltage transformer, the current in the secondary is approximately equal
to the:
A. INDUCED CURRENT
B. VOLT-AMPERE LOAD
C. NUMBER OF TURNS ON THE WINDING
D. PRIMARY AND SECONDARY OVERCUTTENT PROTECTION - Answers- C.
NUMBER OF TURNS ON THE WINDING
The approximate line current per phase on a balanced 3-phased system with a
maximum load per phase of 20, 000 VA and a line of 208 volts is _____ amperes.
A. 55
B. 96
C. 167
D. 288 - Answers- B. 96
Which of the following statements is correct for flexible metal conduit? Flexible metal
conduit is
A. ALLOWED IN STORAGE BATTERY ROOOMS
B. NOT SUITABLE FOR USE IN WET LOCATIONS
C. APPROVED FOR EMBEDMENT IN CONCRETE
C. LIMITED TO 6FT WHEN FINISHED IN EXISTING CONSTRUCTION. - Answers- B.
NOT SUITABLE FOR USE IN WET LOCATIONS
The maximum permitted length of flexible metal conduit permitted between a raceway
and service equipment is ____ft.
A. 3
B. 4
C. 5
D. 6 - Answers- D. 6
The NEC permits 3/8 in. flexible metal conduit to be unsupported for tap connections to
light fixtures, provided the maximum length is ______ft.
A. 3
B. 6
C. 9
D. 12 - Answers- B. 6
A metallic electrical panel that is in an indoor wet location is required to be set out from
the wall a minimum of _____in.
A. 1/32
B. 1/16
C. 1/8
D. 1/4 - Answers- D. 1/4
, #2 Refer to the Level Power plan by clicking on the EXHIBIT button above
For the circuit that serves the outside HP-5 motor compressor conditioning unit, the
maximum rating of the inverse time breaker permitted to provide short-circuit is
___amperes
A. 40
B. 45
C. 60
D. 70 - Answers- C. 60
Give: Two separate services are identical in voltage and amperage, except that one
service serves on motor loads and the other serves lighting loads only.
In the event of a short circuit in these services, the available short-circuit current will be
A. THE SAME IN EITHER SERVICE
B. 25 PERCENT GREATER IN THE SERVICE FOR THE MOTOR LOAD
C. HIGHER IN THE LIGHTING-LOAD SERVICE BECAUSE OF CONTINUOUS LOADS
D. HIGHER IN THE MOTOR-LOAD SERVICE BECAUSE OF THE INDUCTIVE
REACTANCE FROM THE MOTORS. - Answers- B. 25 PERCENT GREATER IN THE
SERVICE FOR THE MOTOR LOAD
#3 Refer to the Electrical Feeder Diagram by clicking on the EXHIBIT button above
Given: The maximum load must not exceed 80 percent of the ampere rating of the main
breaker, and the maximum load must not exceed 80 percent of the ampacity of the
service entrance conductors. The service entrance conductors have XHHW insulation.
The voltage is 208
Rigid polyvinyl chloride conduit, 1 inch in size, must be supported at maximum intervals
of _____ft.
A. 3
B. 5
C. 6
D. 10 - Answers- A. 3
All of the following wiring methods are permitted in a ceiling space used as a return-air
plenum except.
A. A/C
B. EMT
C. IMC
D. MI CABLE - Answers- A. A/C
Given: The cross-sectional area of 10 copper conductors is 0.836 sq. in. The 10
conductors are contained in an 18-in run of RMC between cabinets.
The minimum size RMC required for the 10 conductors is _____ in.
A. 1
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Greaterheights. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.49. You're not tied to anything after your purchase.